Second-hand Analytical Instruments
Filter
Showing 121–150 of 605 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GC 7890A |
| Condition | Refurbished & Certified Pre-Owned |
| Compliance | Fully Tested to Original Agilent Specifications |
| Software | Compatible with OpenLab CDS (Legacy ChemStation Support Available) |
| Detector Options | FID, TCD, ECD, NPD, PID (Configurable per Unit) |
| Column Compatibility | Standard 1/4" and 0.53 mm ID Capillary Columns |
| Carrier Gas | Helium, Hydrogen, or Nitrogen (with Electronic Pressure Control) |
| Temperature Range | Oven: -10 °C to 450 °C (with LN2 cooling option available) |
| Injector | Up to 450 °C |
| Detector | Up to 450 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Operational Age | 4–5 years |
| Configuration | Standard GC system with integrated 7683 autosampler control |
| Regulatory Readiness | Built-in 21 CFR Part 11 compliance features (audit trail, electronic signature support, user access levels) |
| Detection Options | FID, TCD, µECD, NPD, MSD, ICP-MS, and optional PFPD, SCD, AED via Agilent partner ecosystem |
| Injection Modes | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, and volatile analysis interface |
| Data Systems | Compatible with Agilent ChemStation Plus (ChemStore C/S, ChemAccess), PetroQA/QC Cerity NDS |
| Speed Capability | Fast GC mode (up to 10× faster than conventional GC) |
| Sample Introduction | Supports headspace, purge-and-trap, valve injection, and large-volume injection (LVI) without pre-concentration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Age | 4–5 years |
| Configuration | Includes integrated Agilent 7683 autosampler control |
| Detector Options | FID, TCD, µECD, NPD, MSD, ICP-MS, FPD (upgraded), plus optional SCD, PFPD, AED via Agilent Partners |
| Inlet Types | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, VOA |
| Software Compatibility | Agilent ChemStation Plus (ChemStore C/S, ChemAccess), Cerity QA/QC for Petrochemicals |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity requirements |
| GC Speed | Capable of fast GC operation (up to 10× faster than conventional GC) |
| Sample Introduction | Large-volume injection (LVI) enabled, headspace, purge-and-trap, valve-based injection modules available |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 7890A-5975C (G3172A) |
| Instrument Type | Gas Chromatography–Mass Spectrometry (GC-MS) |
| Mass Analyzer | Quadrupole |
| Detector | Triple-Axis Electron Multiplier |
| Mass Range | 1.6–1050 u |
| Scan Speed | Up to 12,000 u/sec |
| Sensitivity | 1 pg OFN (octafluoronaphthalene), S/N ≥ 400:1 (m/z 272) |
| Operating Age | 3–4 years |
| Compliance | Fully Functional per Agilent G3172A Specification |
| Warranty | Not Included |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A-5975C |
| Mass Range | 1–1050 u |
| Scan Rate | 12,500 u/s |
| Sensitivity | 20 pg/μL octafluoronaphthalene (OFN), S/N ≥ 10:1 at m/z 272 |
| Ion Source Temperature | Up to 300 °C |
| Quadrupole | Heated dual-curved rod assembly |
| Carrier Gas Compatibility | Helium, Hydrogen, Nitrogen |
| Software | MSD ChemStation with Deconvolution Reporting Software (DRS), Retention Time Locking (RTL), Capillary Flow Technology support |
| Warranty | 90-day parts and labor |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 7890A (G3440A)-5975C |
| Instrument Type | Quadrupole GC-MS |
| Operating Age | 3–4 years |
| Power Supply | 230 V, 50/60 Hz |
| Shipping Dimensions | 1300 × 650 × 900 mm |
| Shipping Weight | 100 kg |
| Certification Status | CE-compliant post-refurbishment |
| Warranty | Not included |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 7890A-5975C (G3171A) |
| Instrument Type | Gas Chromatography–Mass Spectrometry (GC-MS) |
| Mass Analyzer | Quadrupole |
| Ion Source | Inert Triple-Axis Detector |
| Age | 3–4 years |
| Warranty | None |
| Configuration | Refurbished with CTC GC PAL Autosampler |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 7890A GC / 7000A Triple Quadrupole MS |
| Product Category | Mass Spectrometer |
| Operational Age | 6–8 years |
| Warranty | 12 months |
| Instrument Configuration | Gas Chromatograph coupled with Triple Quadrupole Mass Spectrometer |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A-7000B |
| Product Category | Mass Spectrometer |
| Operational Age | 4 years |
| Warranty | None |
| Price Range | USD $38,000–$64,000 (FOB) |
| Software Platform | MassHunter Workstation v10.x or later |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A-7000B |
| Instrument Type | Triple Quadrupole Gas Chromatography–Mass Spectrometry (GC-MS/MS) System |
| Operational Age | 6–8 years |
| Warranty | 6 months |
| Category | Second-hand Analytical Instrument |
| Compliance | Designed to meet ASTM D5845, EPA Method 8270/1613/1631, and ISO/IEC 17025-aligned laboratory practices |
| Software Platform | MassHunter Workstation (vB.08.x or later, validated for GLP environments) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A–7000A |
| Product Category | Mass Spectrometer |
| Operational Age | 4–5 years |
| Warranty Period | 6 months |
| Instrument Model | 7890A–7000A |
| Usage Duration | 4 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Configuration | GC Mainframe with S/SL Inlet, FID Detector, 80-PAL Autosampler |
| Warranty | 90-day comprehensive hardware warranty |
| Certification | Fully tested and validated per Agilent-recommended performance verification protocols |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B |
| Instrument Type | Gas Chromatograph |
| Age Range | 6–8 years |
| Warranty | 12 months |
| Compliance | Fully refurbished to meet original Agilent performance specifications |
| Software | Compatible with OpenLab CDS (ChemStation legacy support available) |
| Detector Options | FID, TCD, ECD, NPD, PID (configuration-dependent) |
| Column Compatibility | Standard 1/4" and 0.53 mm ID capillary columns |
| Carrier Gas Control | Electronic Pressure Control (EPC) across all inlets and detectors |
| Key | Brand: Agilent |
|---|---|
| Model | 7890B GC + Entech 7100 |
| Origin | Shanghai, China (Distributed by Junqi Instruments) |
| Detector | FPD (Sulfur-Selective) |
| Column | GS-GasPro, 30 m × 0.32 mm |
| Preconcentration System | Entech 7100 + 7032 Autosampler |
| Software | Agilent GC ChemStation + Entech Preconcentrator Control Suite |
| Warranty | 1 year |
| Operational Age | 3 years |
| Compliance | EPA TO-14, TO-15, ASTM D5504, USP <467> |
| Sample Matrix | Ambient air, canister/bag samples, humid up to 100% RH |
| Detection Range | Sub-ppbv for H₂S, CH₃SH, DMS, COS, CS₂ |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Origin | Imported |
| Model | 7890B + 7010B |
| Price | USD 95,000 (FOB) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B + 7000C/D |
| Configuration | GC with ALS G7693A, Heated EI Extractor Ion Source, Gold-Plated Quadrupole Mass Filters, HED-EM Detector, Dual Turbo Molecular Pumping System, MassHunter Software Suite |
| Compliance | ASTM D5845, EPA Methods 8270/1613/1631, USP <621>, ISO/IEC 17025 |
| Service History | Fully Refurbished & Performance-Verified per Agilent OEM Standards |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977B |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Vacuum System | High-Performance Turbomolecular Pump |
| Ion Source | Dual-Filament EI Source, Inert (Non-Coated, Non-Stainless Steel) |
| Mass Analyzer | Gold-Plated Quartz Quadrupole with Turner-Kruge Lenses |
| Mass Range | 1.6–1050 u (0.1 u increments) |
| Resolution | Unit Mass Resolution |
| Mass Stability | ≤0.10 u / 48 h |
| Full-Scan Sensitivity (EI) | ≥400:1 S/N for 1 pg OFN (m/z 272, 50–300 u scan) |
| SIM Sensitivity (EI) | ≥10:1 S/N for 20 fg OFN |
| Max Scan Rate | 12,500 u/s (1 ms dwell in SIM) |
| Dynamic Range | 10⁶ |
| SIM Capacity | 100 groups, up to 60 ions/group |
| GC Oven Temp Range | 4 °C above ambient to 450 °C |
| Max Ramp Rate | 120 °C/min |
| Temperature Stability | <0.01 °C per 1 °C ambient change |
| Programmable Temperature Zones | ≥6 heated zones (including inlet, detector, transfer line), all independently controlled up to 400 °C |
| EPC Pressure Control Accuracy | ±0.001 psi |
| Split/Splitless Inlet | Up to 7500:1 split ratio, 0–1250 mL/min H₂/He flow range |
| Auto-sampler | 16-position (standard), optional 150-position tray |
| Detectors Included | FID (detection limit <1.8 pg C/s), micro-ECD (<6 fg/mL lindane), NPD (<0.4 pg N/s, <0.2 pg P/s) |
| Compliance | Fully compatible with EPA Methods (e.g., 502.2, 524.4, 8260, 8270), USP <621>, ASTM D5845, and GLP/GMP data integrity requirements per FDA 21 CFR Part 11 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977A |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Ion Source | High Efficiency Source (HES) with Electron Ionization (EI) |
| Detection Limit (IDL) | 1.5 fg (as reported for chlorobenzene, per Agilent specification) |
| Sensitivity Gain | Up to 10× vs. prior-generation single quadrupole MSDs |
| Pump Option | IDP-3 Dry Scroll Vacuum Pump (optional, low-noise, oil-free operation) |
| Software Platform | Agilent MassHunter Workstation (v10.x or later, license transferable per Agilent policy) |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| Column Oven Temperature Range | 0–450 °C |
| Maximum Ramp Rate | 120 °C/min |
| Detector Compatibility | FID, TCD, ECD, NPD, FPD, MSD (with appropriate interface) |
| Software Platform | OpenLab CDS (ChemStation-compatible mode available) |
| Compliance | ASTM D3606, D5186, ISO 10301, USP <621>, FDA 21 CFR Part 11 (when configured with audit trail & electronic signature) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B GC / 5977A MSD |
| Configuration | G4513A + G4514A (7693A) Autosamplers (150-position tray), Edwards Turbo Pump, MassHunter Software Suite |
| Warranty | 90-day comprehensive hardware warranty |
| Condition | Refurbished & fully validated by SpectraLab Scientific |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B-5977B |
| Instrument Type | Single Quadrupole Gas Chromatography-Mass Spectrometry (GC/MS) System |
| Typical Service Life | 6–8 years |
| Warranty | 12 months post-installation |
| Compliance | ASTM D5845, EPA Methods 524/8260/8270, ISO 17025-compatible operation |
| Software Platform | MassHunter Workstation (v10.2 or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890B GC, G7010A MS |
| Product Category | Mass Spectrometer |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Instrument Model | 7890B, G7010A |
| Instrument Age | 4 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8000 |
| Usage Duration | 2–3 years (as verified) |
| Warranty | 6 months |
| Instrument Age | 4 years |
| Configuration | Includes Agilent 810 peristaltic pump |
| Certification Status | Functionally tested and validated by SpectraLab Scientific |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8453 |
| Wavelength Range | 190–1100 nm |
| Detector | 1024-element Diode Array |
| Wavelength Accuracy | < ±0.2 nm (at 486.0 nm & 656.1 nm) |
| Wavelength Repeatability | < ±0.02 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | < 0.03% T (at 340 nm, NaNO₂ solution, ASTM method) |
| Photometric Accuracy | ±0.005 A (at 440 nm & 590 nm, 1.0 A NDL) |
| Baseline Flatness | ±0.001 A |
| Stability | ±0.001 A/h |
| Light Source | Pre-aligned Deuterium & Tungsten Lamps |
| Interface | GPIB & LAN |
| Compliance | USP <857>, EP 2.2.25, FDA 21 CFR Part 11 (with optional security software) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8860-5977B |
| Price Range | USD 68,000 – 136,000 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | AA 280Z |
| Instrument Type | Atomic Absorption Spectrometer |
| Detection Principle | Zeeman-effect background-corrected graphite furnace AAS |
| Lamp Positions | 8 fixed hollow cathode lamp positions |
| Atomizer | Agilent GTA 120 Zeeman graphite furnace atomizer |
| Autosampler | Agilent PSD 120 programmable sample dispenser |
| Software Platform | Agilent Windows-based worksheet software with SRM Wizard and Tube-Cam functionality |
| Operational Age | 4 years |
| Warranty | 6 months limited hardware warranty |
| Compliance | Designed to support GLP/GMP workflows |
| Sample Introduction | Electrothermal (graphite tube) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | AA 240Z |
| Instrument Type | Atomic Absorption Spectrometer (Graphite Furnace, Zeeman Background Correction) |
| Detection Principle | AC-modulated Zeeman-effect background correction with graphite furnace atomization |
| Lamp Configuration | Up to 4 fixed hollow cathode lamp positions |
| Atomizer | Agilent GTA 120 Zeeman graphite furnace atomizer |
| Autosampler | Agilent PSD 120 programmable autosampler |
| Software Platform | Agilent Windows-based worksheet software with SRM Wizard and Tube-Cam functionality |
| Operational Age | 4 years |
| Warranty | 6 months limited warranty |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Varian |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | G7361A |
| Product Category | Chromatography |
| Usage Duration | 4 years |
| Warranty Period | 6 months |
| Instrument Model | G7361A |
| Condition | Refurbished, Fully Tested |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Cary 100 |
| Product Category | Spectroscopy |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Absorbance Range | >3.5 Abs |
| Software | WinUV |
| Slit Width | Variable |
| Optical Design | Sealed quartz-coated optics |
| Compliance | ASTM E275, ISO 6223, USP <857> |
| Sample Handling | Liquid cuvette holder included |
| Scan Speed | High-speed scanning with phase-locked wavelength drive |
| Detector | Silicon photodiode |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Cary 8454 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Light Source | Pre-aligned Deuterium and Tungsten Lamps |
| Detector | Photodiode Array (PDA) |
| Scan Speed | Full Spectrum Acquisition in <1 Second |
| Compliance | USP <85>, EP 2.2.25, FDA 21 CFR Part 11 Ready, GLP/GMP-Ready Firmware |