Empowering Scientific Discovery

Shandong Jinpu Analytical Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGolden普
OriginShandong, China
ModelOG-2000VA
Instrument TypePortable Gas Chromatograph
Application FieldPetroleum & Petrochemical Industry
Oven Temperature RangeAmbient +4°C to 450°C
Oven Ramp Rate0.1–40°C/min
Oven Cool-down Rate400°C → 50°C in ~6 min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & ControlUp to 900 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting RangeUp to 900 kPa
Injector Total Flow Setting Range0–1200 mL/min
FID Detection Limit (Hydrocarbons)0.001 mg HC/g rock
FID Baseline Drift< 0.1 mV/30 min
FID Linear Dynamic Range10⁶
FID Temperature Stability360 ± 0.5°C
Pyrolysis Furnace Temperature Stability600 ± 0.5°C
Programmable Pyrolysis Cycles4 (Source Rock, Reservoir Rock, Thermal Simulation, User-Defined)
Ramp Linearity Deviation< 0.5°C/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGolden Promise
ModelOG-2000V
OriginShandong, China
Instrument TypeRock Pyrolysis Analyzer for Geochemical Evaluation of Source Rocks
ComplianceDesigned for ASTM D5307 / ISO 10374 / SY/T 5115-2014
Detection PrincipleControlled-Temperature Pyrolysis coupled with Flame Ionization Detection (FID) and Thermal Conductivity Detection (TCD)
Sample FormCrushed core or cuttings (dry, <1 mm particle size)
Temperature RangeAmbient to 650 °C (programmable ramp rates)
Data InterfaceUSB 2.0 (Windows-compatible, driver-free operation)
Measurement OutputS1 (free hydrocarbons), S2 (kerogen-derived hydrocarbons), S3 (CO₂ from organic carbon), Tmax (peak pyrolysis temperature), HI/OI (Hydrogen Index / Oxygen Index)
Accuracy±2% FS for S1/S2
Power Supply220 VAC, 50 Hz, 1.5 kW
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandKingpu
OriginShandong, China
ModelGC-8890 Dedicated for DME in LPG
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry
Temperature Control RangeAmbient + 8°C to 420°C
Oven Ramp Rate0.1–40°C/min
Oven Cool-down450°C to 50°C in ~6 min
Carrier Gas Flow Range & Control0–1200 mL/min (7 programmable segments)
Carrier Gas Pressure Range & Control0–970 kPa (7 programmable segments)
Injector Max Temp450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelJP-300E
Gas PurityN₂ ≥ 99.999%, H₂ ≥ 99.99995%, Air (HC < 0.1 ppm)
Output FlowN₂: 0–500 mL/min, H₂: 0–500 mL/min, Air: 0–5 L/min
Output PressureN₂/H₂: 0.3 MPa, Air: 0.4 MPa
DesignIntegrated monolithic chassis
Power SupplyAC 220 V, 50 Hz
Max. Power Consumption550 W
Dimensions (L×W×H)480 × 420 × 480 mm
Weight45 kg
Operating Environment0–40 °C, RH < 85%, non-corrosive, low-dust ambient
ComplianceDesigned for GLP-compliant GC laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGAS-10A
Sample Capacity10 gas sampling bags
Control InterfaceLCD touch screen
ActuationSolenoid-valve-based automated sequencing
Application DomainAmbient air pre-concentration, VOC analysis, environmental monitoring, laboratory GC/GC-MS sample introduction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelJPA-3L
Output Flow Rate2.0–3000 mL/min
Output Pressure0.4 MPa
Noise Level<30 dB(A)
Dimensions (L×W×H)415 × 200 × 370 mm
Weight~22 kg
Power Consumption≤150 W
Input Voltage220 ± 22 V AC, 50 ± 0.5 Hz
Operating Temperature10–40 °C
Relative Humidity≤85% RH
Air PurityOil-free and desiccated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-8890SD
Instrument TypeLaboratory Gas Chromatograph
Application FieldPower Industry Dedicated
Temperature Control RangeAmbient +6°C to 399°C (adjustable in 1°C increments)
Ramp Rate0–40°C/min (adjustable in 0.1°C increments)
Cooling Rate≤3 min (from 200°C to 100°C)
Carrier Gas Flow Range & Control0–1200 mL/min, 7-step programmable
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGolden Promise
ModelGC-8890SD
OriginShandong, China
Weight60 kg
Dimensions (L×W×H)565 × 505 × 500 mm
Detection Limit≤1×10⁻¹² g/s (n-C₁₆, FID)
Connectivity10/100M Ethernet (IEEE 802.3)
Column Oven Temp Range5–400 °C (0.1 °C increment, ±0.1 °C stability)
Max Heating Rate40 °C/min (programmable up to 20 steps)
Cooling Rate≤3 min (200 → 100 °C)
Detector OptionsFID, TCD (configurable)
Power Supply220 V ±10%, 50 Hz ±0.5 Hz, 2500 W max
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelOG-2000V
Instrument TypeLaboratory Gas Chromatograph for Geochemical Pyrolysis
Application DomainPetroleum & Petrochemical Industry
Temperature Control Range360 ± 0.5 °C (FID), 600 ± 0.5 °C (Pyrolysis Furnace & Oxidation Furnace)
Ramp Rate< 0.5 °C/min
Maximum Injector Temperature800 °C
Detection PrincipleFlame Ionization Detection (FID)
Minimum Hydrocarbon Detection0.001 mg HC/g rock
Baseline Drift< 0.1 mV/30 min
Linear Dynamic Range10⁶
Analysis Cycle Time (Full Pyrolysis–Residual Carbon)14.5 min
Number of Predefined Thermal Programs4 (Source Rock, Reservoir Rock, Thermal Simulation, User-Defined)
Temperature Linearity Deviation< 0.5 °C/min
InterfaceUSB 2.0 (Direct Signal Output to PC)
Show next