Shandong Jinpu Analytical Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelLC-3000
Maximum Pressure (P3110)42 MPa
Maximum Pressure (P3120)30 MPa
Flow Range (P3110)0.002–9.998 mL/min
Flow Range (P3120)0.01–49.99 mL/min
Flow Accuracy±2% (at 2–5% of full scale, MeOH/H₂O 80:20 v/v)
Flow PrecisionRSD < 0.1%
Wavelength Range (UV3000)190–700 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability0.4 nm
Baseline Noise2 × 10⁻⁵ AU/h (254 nm, 1 mL/min, MeOH/H₂O 80:20)
Baseline Drift15 × 10⁻⁵ AU/h (254 nm, 1 mL/min, MeOH/H₂O 80:20)
Detection Range0–2 AU
Time Constants0.1/0.2/0.5/1/2/5/10 s
Dimensions (W×H×D)398 × 149 × 267 mm
Weight14 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-7890
Instrument TypeLaboratory Gas Chromatograph
Application FieldCoal Mining Industry
Detection TargetsH₂, O₂, N₂, CO, CO₂, CH₄, C₂H₄, C₂H₆, C₂H₂
Minimum Detectable ConcentrationsH₂ ≤ 5 ppm
TCD Sensitivity≥ 2500 mV·mL/mg (n-hexadecane)
FID Detection Limit5 × 10⁻¹² g/s (n-hexadecane)
Column Oven Temp Range10–399 °C (1 °C increment)
Control Accuracy±0.1 °C
Detector Temp Range10–399 °C
TCD Control Accuracy±0.01 °C
Data Acquisition24-bit A/D, USB interface, 6–50 Hz sampling rate, dynamic range 10⁶
Dimensions606 × 450 × 450 mm (W×H×D)
Weight45 kg
Power Supply220 V, 50 Hz, 2100 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-7890
Instrument TypeBenchtop Laboratory Gas Chromatograph
Temperature Range-80 °C to 450 °C (with cryogenic cooling)
Column CompatibilityDual packed columns or dual capillary columns
Detector ConfigurationsDual TCD, Dual FID, or hybrid TCD/FID
Programmed Temperature7-step ramp, 6-zone independent temperature control
Injector OptionsManual, auto-sampler, headspace, thermal desorption, gas valve
Detection Sensitivity (FID)≤1×10⁻¹¹ g/s (benzene)
(ECD)≤1×10⁻¹³ g/mL (γ-HCH)
(NPD)≤5×10⁻¹² g/s (azobenzene)
Temperature Accuracy±0.1 °C
Heating Rate0.1–40 °C/min
Power SupplyAC 220 V ±10%, 50 Hz, 2.2 kW
Dimensions660 × 460 × 465 mm
Weight60 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJP
OriginShandong, China
ModelGC-8890
Instrument TypeBenchtop Laboratory Gas Chromatograph
Temperature Control RangeAmbient +4 °C to 450 °C
Temperature Precision±0.1 °C
Programmable Temperature Ramping16-step, up to 80 °C/min
Electronic Pressure/Flow Control (EPC/EFC)4-stage programming, 0–0.6 MPa pressure range, 0–500 sccm flow range, resolution: 0.01 kPa / 0.01 sccm
Detectors SupportedFID (Mt ≤ 2×10⁻¹² g/s), TCD (S ≥ 12,000 mV·mL/mg), ECD (M ≤ 2×10⁻¹⁴ g/mL), FPD, NPD
Inlet OptionsSplit/splitless, PTV, headspace, pyrolysis
ComplianceDesigned for GLP-compliant laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandGolden Promise
OriginShandong, China
ModelGC-2011
Detection PrinciplesDual-channel gas chromatography with simultaneous TCD and FID detection
Temperature Control8°C above ambient to 420°C (±0.1°C ≤200°C
Programmed Temperature Ramping8-step linear ramping, 0.1–30°C/min (0.1°C increment)
Detector SensitivityFID: ≤1×10⁻¹¹ g/s (benzene)
TCD≥3500 mV·mL/mg (benzene)
Column CompatibilityDual-inlet system — packed column inlet (TCD-optimized) + dedicated split/splitless capillary inlet with tail-purge
Dimensions540 × 455 × 465 mm
Weight50 kg
PowerAC 220 V ±10%, 50 Hz, ~2 kW]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-7890 (Black Chassis)
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range5°C above ambient to 450°C (adjustable in 0.1°C increments)
Oven Ramp Rate0.1–40°C/min (adjustable in 0.1°C increments)
Oven Cooling Rate450°C → 50°C in ≤6 min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
FID Detection Limit≤3×10⁻¹² g/s (n-hexadecane)
FID Noise≤3×10⁻¹⁴ A
FID Drift≤5×10⁻¹³ A/30 min
FID Linear Dynamic Range≥10⁶
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-8890
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Temperature Control Range4 °C above ambient to 450 °C (1 °C increment
Oven Ramp Rate0.1–80 °C/min
Cooling Rate450 °C → 50 °C in ≤6 min
Carrier Gas Flow Range & Control0–1000 mL/min (4-program segments)
Carrier Gas Pressure Range & Control0–500 kPa (4-program segments)
Injector Max Temp450 °C
Injector Pressure Setting Range0–500 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC_8890
Instrument TypeOnline Gas Chromatograph
Application FieldPetrochemical Industry
Temperature Control RangeAmbient + 8 °C to 420 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-down Rate450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–1200 mL/min (7 programmable segments)
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-8890PLUS
Weight17 kg
Dimensions (W×D×H)560 × 440 × 260 mm
Detection Limits (µL/L)H₂: 1, CO: 3, CO₂: 10, CH₄: 20, C₂H₆: 50, C₂H₄: 0.1, C₂H₂: 0.1, O₂/N₂: 10
Column Temperature RangeAmbient +4 °C to 450 °C
Temperature Control Precision±0.05 °C
Programmable Temperature Ramps20 oven steps, 7 injection port steps
DetectorsTCD, FID, Ni methanizer
EPCFull electronic pressure/flow control
ComplianceGB/T 17623–2017, GB/T 7252–2001, DLT 722–2014
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelLC-4000
Instrument TypeAnalytical-Grade High-Performance Liquid Chromatograph
Flow Rate Range0.001–10.000 mL/min (adjustable in 0.001 mL/min increments)
Maximum Operating Pressure43 MPa
Sample Injection Volume1–50 µL
Autosampler Capacity100 positions (1.5 mL vials)
Column Oven Temperature RangeAmbient +10 °C to 60 °C
UV-Vis Wavelength Range170–900 nm
Data Acquisition Rate100 Hz
Flow Accuracy≤ ±1% (at 1.000 mL/min, 8.5 MPa, water, 25 °C)
Flow PrecisionRSD ≤ 0.25%
Baseline Noise≤ 2 × 10⁻⁵ AU (methanol, 1 mL/min, 254 nm, 20 °C)
Baseline Drift≤ 4 × 10⁻⁴ AU/hr (methanol, 1 mL/min, 254 nm, 20 °C, 60 min equilibration)
Cell Volume10 µL
Optical Path Length5 mm
Light SourceDeuterium Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandGolden Promise
ModelLC-3000
TypeHPLC-Based Melamine Quantification System
OriginShandong, China
Instrument ClassBenchtop Liquid Chromatograph for Targeted Small-Molecule Analysis
Detection PrincipleUV-Vis Absorption at 240 nm with Diode Array or Fixed-Wavelength UV Detector
Column CompatibilityReversed-Phase C8/C18 (e.g., 250 mm × 4.6 mm, 5 µm)
Flow Rate Range0.1–2.0 mL/min
Column Oven Temperature ControlAmbient to 60 °C
Sample Injection Volume5–100 µL (manual or optional autosampler-ready)
Regulatory AlignmentDesigned for ASTM D7968-19, ISO 17394:2015, and GB/T 22388–2008 compliant workflows
SoftwarePC-based chromatography data system (CDS) with peak integration, calibration curve generation (linear/non-linear), audit trail, and report export (PDF/CSV)]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
ModelGC-2011
Detector OptionsFID or TCD
Temperature Control Range8 °C above ambient to 420 °C
Temperature Stability±0.1 °C (≤200 °C), ±0.2 °C (>200 °C)
Ramp Rate1–30 °C/min
Programmed Temperature5-step
FID Sensitivity≤2×10⁻¹¹ g/s (benzene), Linear Range: 10⁷
TCD Sensitivity≥2500 mV·mL/mg (benzene)
Noise≤0.02 mV
Drift≤0.1 mV/h
Column ConfigurationSingle-column, dual-gas-path
InjectorPacked-column vaporizer + dedicated capillary inlet
Oven CoolingIntelligent variable-frequency rear-door cooling to near-ambient
Safety FeaturesOvertemperature cutoff, gas failure/leak detection, power-fail parameter retention, anti-surge protection
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandJinpu
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGC-7890
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient +5°C to 450°C (adjustable in 0.1°C increments)
Ramp Rate0.1–40°C/min (0.1°C increment)
Cooling Rate450°C → 50°C in ≤6 min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Stability (≤180°C)±0.01°C
Column Configuration SupportDual packed columns + one capillary column, or dual capillary columns
Detector CompatibilityDual TCD, dual FID, or simultaneous TCD/FID operation
Programmed Temperature8-step ramping across 6 independently controlled zones
Auto-IgnitionYes (patented)
Automatic Sample InjectionYes (patented)
Power Supply220 V ±10%, 2200 W max
FID Sensitivity≤3×10⁻¹² g/s (benzene on CS₂), Noise: ≤3×10⁻¹³ A, Drift: ≤5×10⁻¹³ A/30 min, Linearity: ≥10⁶]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelOG-3000
Instrument TypeLaboratory Gas Chromatograph for Rock Pyrolysis
Application FieldPetroleum & Petrochemical Industry
Injector Maximum Temperature90–850 ± 0.5 °C (programmable)
FID Hydrocarbon Detection Limit0.001 mg HC/g rock
FID Baseline Drift< 0.1 mV/30 min
FID Linear Range10⁶
IR Detector Range0–100 %
IR Linearity Error≤ ±1 % F.S.
IR Repeatability< 1 %
IR Zero Drift≤ ±2 % F.S./24 h
Pyrolysis Furnace Temp Control Accuracy±0.5 °C
Oxidation Furnace Temp Control Accuracy±0.5 °C
Programmable Ramp SegmentsUp to 10 segments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory Gas Chromatograph
ModelGC-7890 Touchscreen
Application FieldEnvironmental Monitoring & Food & Beverage Quality Control
Column Oven Temperature Range+5 °C to 450 °C (0.1 °C increments)
Temperature Accuracy±0.1 °C
Max Heating Rate40 °C/min
Cooling CapabilityDown to –80 °C with cryogenic coolant (dry ice or liquid nitrogen)
Detector OptionsDual FID, Dual TCD, FID+TCD, plus ECD, NPD, FPD
Simultaneous Column ConfigurationTwo packed columns + one capillary column, or two capillary columns
Independent Injector & Detector ZonesSix temperature-controlled zones
Programmed Temperature RampingUp to 7 steps
Power SupplyAC 220 V ±10%, 50 Hz, 2.2 kW
Dimensions660 × 460 × 465 mm
Weight60 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-7890
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature Range5 °C above ambient to 400 °C (adjustable in 0.1 °C increments)
Ramp Rate0.1–40 °C/min (adjustable in 0.1 °C/min increments)
Cool-down Rate450 °C to 50 °C in ≤6 minutes
Carrier Gas Flow Range & Control0–1200 mL/min (7 flow segments)
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Stability (≤180 °C)±0.01 °C
Temperature Accuracy≤±0.1 °C
Temperature Gradient (100–360 °C, programmed ramp)±1 °C
Column ConfigurationDual packed columns + one capillary column, or dual capillary columns
Detector CapacityUp to three detectors simultaneously (e.g., dual TCD, dual FID, or TCD+FID), plus optional methanizer
Inlet OptionsManual, auto-sampler compatible, valve injection, headspace, thermal desorption, liquid autosampler
Power Supply220 V ±10%, max. 2200 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGolden普
ModelGC-2011 (New Generation)
OriginShandong, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature RangeAmbient +8°C to 420°C
Temperature Control Accuracy±0.1°C (≤200°C), ±0.2°C (>200°C)
Programmable Temperature Ramping5-stage linear ramping
Ramp Rate1–30°C/min (0.1°C increment)
Cooling Rate350°C → 100°C in ≤3.5 min
Detector OptionsFID (Mf ≤2×10⁻¹¹ g/s for benzene) or TCD (S ≥3000 mV·mL/mg for benzene)
Dimensions540 × 470 × 460 mm
Weight50 kg
Power SupplyAC 220 V ±10%, 50 Hz, 2 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelOG-2000V Online Gas Chromatograph for Hydrocarbon Show Evaluation
Instrument TypeOnline Gas Chromatograph
Application FieldGeneral-purpose Geochemical Logging & Rock Pyrolysis Analysis
Detector ConfigurationDual Flame Ionization Detectors (FID)
Cooling SystemIntegrated Forced-air Cooling Module
InterfaceUSB 2.0 Digital Output
DisplayHigh-contrast Backlit LCD with Chinese Language Support
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandGolden Promise
OriginShandong, China
ModelGC-7890
Instrument TypeOnline Gas Chromatograph
Application FieldGeneral-Purpose Industrial Process Analysis
Temperature Control Range5 °C to 450 °C
Oven Temperature Stability±0.1 °C (≤200 °C), ±0.2 °C (>200 °C)
Ramp Rate1–30 °C/min
Cooling RateVariable, enabled by intelligent back-door temperature modulation
Carrier Gas Flow ControlDigital mass flow control (MFC) compatible with He, H₂, N₂
Carrier Gas Pressure ControlElectronic pressure control (EPC) with 0–1000 kPa range
Injector Max Operating Temperature450 °C
Injector Pressure Setting Range0–1000 kPa
Total Injector Flow Setting Range0–200 mL/min
DetectorsFID (MDL ≤1×10⁻¹¹ g/s benzene), TCD (Sensitivity ≥3000 mV·mL/mg benzene), optional ECD/FPD/NPD support
Column CompatibilityDual packed-column inlets + dedicated split/splitless capillary inlet with makeup gas and tail-purge capability
Thermal Programming5-step programmable ramping
Safety FeaturesPower-fail memory, overtemperature cutoff, carrier gas failure protection, real-time fault diagnostics]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-7890SD
Instrument TypeLaboratory Gas Chromatograph
Application FieldPower Industry Dedicated
Oven Temperature RangeAmbient + 5°C to 420°C
Oven Ramp Rate0.1–40°C/min
Oven Cool-down450°C to 50°C in ~6 min
Carrier Gas Flow Range & Control0–1200 mL/min (7-program segments)
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-2011 (Latest Revision)
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose Chemical Analysis
Oven Temperature Range8–420 °C
Oven Ramp Rate0.1–30 °C/min (0.1 °C/min increments)
Temperature Stability±0.1 °C within 200 °C
Carrier Gas Flow ControlElectronic Pressure Control (EPC)-compatible design
Carrier Gas Pressure ControlSupports precision pressure regulation
Cooling RateRapid cool-down to near-ambient (≤200 °C) via intelligent variable-frequency rear door system
Column CompatibilityPacked columns and capillary columns (split/splitless injection)
Standard DetectorsFID and/or TCD
Dimensions540 × 455 × 465 mm
Weight50 kg
Power SupplyAC 220 V ±10%, 50 Hz, 2 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose / EO Residual Testing
Temperature Control Range5°C above ambient to 400°C (adjustable in 0.1°C increments)
Oven Ramp Rate0.1–40°C/min (0.1°C increment)
Oven Cool-Down450°C → 50°C in ≤6 min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Signal OutputsDual analog (A/B), RJ45 Ethernet interface
Gas InletsH₂, Air, Optional H₂ supply lines
Power InputStandard AC mains with integrated fuse and charging circuitry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJinpu
OriginShandong, China
ModelGC-8890PLUS
Instrument TypeLaboratory Gas Chromatograph
Application FieldEnvironmental Analysis
Temperature Control Range5°C above ambient to 450°C
Maximum Ramp Rate120°C/min
Cooling Rate≤3.5 min from 350°C to 100°C
Carrier Gas Flow Range & Control0–300 mL/min
Carrier Gas Pressure Range & Control0–100 psi
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–300 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJP
OriginShandong, China
ModelGC-2011
Instrument TypeBenchtop Laboratory Gas Chromatograph
Detector Standard ConfigurationFID & TCD
Optional DetectorsECD, FPD, NPD
Temperature Control RangeAmbient +8°C to 420°C
Temperature Accuracy±0.1°C ≤200°C
Ramp Rate1–30°C/min
FID Detection Limit≤1×10⁻¹¹ g/s (benzene)
FID Noise≤0.02 mV
FID Drift≤0.1 mV/h
TCD Sensitivity≥3000 mV·mL/mg (benzene)
TCD Noise≤0.02 mV
TCD Drift≤0.1 mV/h
Programmable Temperature Program5-step ramp
Column Oven CoolingIntelligent variable-frequency rear-door system enabling near-ambient operation
Inlet SystemsDual packed-column inlets + dedicated split/splitless capillary inlet with tail-purge
Data SystemEmbedded microprocessor with LCD interface
ComplianceDesigned to support GLP-compliant workflows