Add to compare
BrandCOMECAUSE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeGeneral-Purpose Automatic Potentiometric Titrator
Application ScopeUniversal
Potential Measurement Range−2000 to +2000 mV
Potential Resolution0.1 mV
Titration Precision±5 µL (for 10 mL burette)
Potential Display Resolution0.1 mV
ComplianceJJG 814–2015 Class 0.05 (Max. Indication Error: ±1.5%
pH Range0–14
pH Resolution0.01
pH Accuracy±0.01
Conductivity Range0.00 µS/cm–2000 mS/cm
Temperature Range−5 to 105 °C
Resolution0.1 °C
Accuracy±0.2 °C
Operating SystemAndroid 10
Display7-inch capacitive touchscreen
Data Storage≥100,000 records
ConnectivityUSB, Wi-Fi, Ethernet
Dimensions310 × 226 × 233 mm
Weight3.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
OriginShandong, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelIN-SLM
PriceUSD 16,800 (approx.)
Excitation Wavelength785 ± 0.5 nm
Laser Linewidth< 0.08 nm
Laser Power0–500 mW (software-adjustable)
Spectral Range200–3800 cm⁻¹
Spectral Resolution5 cm⁻¹
Integration Time1 ms – 10 s (typical acquisition: 500 ms)
DetectorHigh-sensitivity CCD/CMOS with fluorescence suppression optics
Optical DesignMiniaturized confocal micro-optics
Operating Temperature0–50 °C
Operating Humidity5–80 % RH (non-condensing)
IP RatingIP67
Display5.5-inch capacitive touchscreen
Camera13 MP integrated visible-light camera with geotagging
ConnectivityUSB-C, Bluetooth 5.0, Wi-Fi 5 (802.11ac), optional 4G LTE
Onboard Storage2 GB RAM + 16 GB eMMC (expandable to 8 GB + 32 GB)
Battery7.4 V / 3.5 Ah Li-ion, 4–6 h typical runtime
OSAndroid 12
Data ExportPDF reports with spectral overlay, metadata, GPS coordinates, timestamp, and audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-DK2
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Gas DetectionO₂ (0–30% vol, resolution 0.01% vol, accuracy ≤±0.2% in 0–50%, ≤±2% in 50–100%), CO₂ (0–100% vol, resolution 0.01% vol, accuracy ≤±2% in 0–50%, ≤±3% in 50–100%)
Sensor TypesElectrochemical (O₂), NDIR Infrared (CO₂)
Sample Volume<5 mL (O₂), <15 mL (CO₂)
Response Time≤15 s (O₂), ≤20 s (CO₂)
Pressure Range700–1500 mbar (abs.)
Sampling MethodIntegrated diaphragm pump with sterile piercing needle
Data Storage2000 records (circular buffer)
Battery6800 mAh Li-ion, operating time >12 h
Dimensions180 × 106 × 80 mm
Weight450 g
Operating Temperature0–40 °C
CalibrationTwo-point (zero/span) with certified gas standards
Compliance ReferenceJJG 365–2008 (Chinese metrological verification regulation for electrochemical oxygen analyzers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-D4
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeGeneral-Purpose Automatic Potentiometric Titrator
Application ScopeUniversal
Potential Measurement Range−2000 to +2000 mV
Potential Resolution0.1 mV
Potential Accuracy±0.25 ‰ of full scale
Potential Stability±0.3 mV / 3 h
Titration Precision±5 µL (for 10 mL burette)
Titration Resolution0.1 mV
pH Range0–14
pH Resolution0.01
pH Accuracy±0.01
Conductivity Range0.00 µS/cm – 2000 mS/cm
Conductivity Accuracy±1.0 % FS
Temperature Range−5 °C to +105 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Display7-inch Android 10 touchscreen
Data Storage100,000 records
ConnectivityUSB / Wi-Fi / Ethernet
Dimensions310 × 226 × 233 mm
Weight3.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-DK1
TypePortable Headspace Gas Analyzer
Measurement PrincipleElectrochemical O₂ Sensor (Primary), Optional NDIR CO₂ Sensor
Gas TargetsO₂ (0–30% vol), CO₂ (0–100% vol, optional)
Resolution0.01% vol
Accuracy±0.2% vol (O₂, 0–50%), ±2% (O₂, 50–100%)
Response Time≤15 s (O₂), ≤20 s (CO₂)
Sampling Volume<5 mL (O₂), <15 mL (CO₂)
Pressure Range700–1500 mbar (abs.)
CalibrationTwo-point (zero/span)
Data Storage2000 entries (circular buffer)
InterfaceUSB 2.0
PowerRechargeable 6800 mAh Li-ion battery
Operating Temperature0–40 °C
Dimensions180 × 106 × 80 mm
Weight450 g
ComplianceDesigned per JJG 365–2008 (Chinese Metrological Verification Regulation for Electrochemical Oxygen Analyzers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelIN-D1
Instrument TypeGeneral-purpose Potentiometric Titrator
Application ScopeUniversal
Potential Range−2000 to +2000 mV
Potential Resolution0.1 mV
Titration Precision±5 µL (for 10 mL burette)
Potential Resolution (display)0.1 mV
pH Range0–14
pH Resolution0.01
pH Accuracy±0.01
Temperature Range−5 to 105 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Repeatability≤0.2%
Maximum Error≤±1.5%
Burette Options10 mL (±5 µL), 20 mL (±10 µL)
Operating SystemAndroid 10
Display7-inch capacitive touchscreen
Data Storage Capacity100,000 records
ConnectivityUSB, Wi-Fi, Ethernet
Dimensions310 × 226 × 233 mm
Weight3.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-DK3
TypePortable Headspace Gas Analyzer
Measurement PrincipleElectrochemical (O₂) & Non-Dispersive Infrared (NDIR, CO₂)
Gas TargetsO₂ (0–30% vol), CO₂ (0–100% vol)
Resolution0.01% vol for both
Accuracy±0.2% vol (O₂, 0–50%)
Response Time≤15 s (O₂), ≤20 s (CO₂)
Sample Volume<5 mL (O₂), <15 mL (CO₂)
Sampling MethodIntegrated diaphragm pump with needle probe
CalibrationTwo-point (zero/span) using certified gases
Pressure Range700–1500 mbar (abs.)
Data Storage2000 records (circular buffer)
InterfaceUSB 2.0
Battery6800 mAh Li-ion, >12 h continuous operation
Operating Temperature0–40 °C
Dimensions180 × 106 × 80 mm
Weight450 g
ComplianceDesigned per JJG 365–2008 (Chinese metrological verification regulation for electrochemical oxygen analyzers)
Language SupportSwitchable English/Chinese UI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelIN-D3
Instrument TypeGeneral-Purpose Automatic Potentiometric Titrator
Application ScopeUniversal Laboratory Use
Potential Range−2000 to +2000 mV
Potential Resolution0.1 mV
Titration Accuracy±5 µL (for 10 mL burette)
Potential Basic Error±0.25 ‰/FS
pH Range0–14
pH Resolution0.01
pH Accuracy±0.01
Temperature Range−5 to 105 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Data Storage Capacity100,000 records
Operating SystemAndroid 10
Display7-inch capacitive touchscreen
ConnectivityUSB, Wi-Fi, Ethernet
Dimensions310 × 226 × 233 mm
Weight3.7 kg