Empowering Scientific Discovery

Shandong Laiyin Optoelectronics Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-DK2
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Gas DetectionO₂ (0–30% vol, resolution 0.01% vol, accuracy ≤±0.2% in 0–50%, ≤±2% in 50–100%), CO₂ (0–100% vol, resolution 0.01% vol, accuracy ≤±2% in 0–50%, ≤±3% in 50–100%)
Sensor TypesElectrochemical (O₂), NDIR Infrared (CO₂)
Sample Volume<5 mL (O₂), <15 mL (CO₂)
Response Time≤15 s (O₂), ≤20 s (CO₂)
Pressure Range700–1500 mbar (abs.)
Sampling MethodIntegrated diaphragm pump with sterile piercing needle
Data Storage2000 records (circular buffer)
Battery6800 mAh Li-ion, operating time >12 h
Dimensions180 × 106 × 80 mm
Weight450 g
Operating Temperature0–40 °C
CalibrationTwo-point (zero/span) with certified gas standards
Compliance ReferenceJJG 365–2008 (Chinese metrological verification regulation for electrochemical oxygen analyzers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-DK1
TypePortable Headspace Gas Analyzer
Measurement PrincipleElectrochemical O₂ Sensor (Primary), Optional NDIR CO₂ Sensor
Gas TargetsO₂ (0–30% vol), CO₂ (0–100% vol, optional)
Resolution0.01% vol
Accuracy±0.2% vol (O₂, 0–50%), ±2% (O₂, 50–100%)
Response Time≤15 s (O₂), ≤20 s (CO₂)
Sampling Volume<5 mL (O₂), <15 mL (CO₂)
Pressure Range700–1500 mbar (abs.)
CalibrationTwo-point (zero/span)
Data Storage2000 entries (circular buffer)
InterfaceUSB 2.0
PowerRechargeable 6800 mAh Li-ion battery
Operating Temperature0–40 °C
Dimensions180 × 106 × 80 mm
Weight450 g
ComplianceDesigned per JJG 365–2008 (Chinese Metrological Verification Regulation for Electrochemical Oxygen Analyzers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-DK3
TypePortable Headspace Gas Analyzer
Measurement PrincipleElectrochemical (O₂) & Non-Dispersive Infrared (NDIR, CO₂)
Gas TargetsO₂ (0–30% vol), CO₂ (0–100% vol)
Resolution0.01% vol for both
Accuracy±0.2% vol (O₂, 0–50%)
Response Time≤15 s (O₂), ≤20 s (CO₂)
Sample Volume<5 mL (O₂), <15 mL (CO₂)
Sampling MethodIntegrated diaphragm pump with needle probe
CalibrationTwo-point (zero/span) using certified gases
Pressure Range700–1500 mbar (abs.)
Data Storage2000 records (circular buffer)
InterfaceUSB 2.0
Battery6800 mAh Li-ion, >12 h continuous operation
Operating Temperature0–40 °C
Dimensions180 × 106 × 80 mm
Weight450 g
ComplianceDesigned per JJG 365–2008 (Chinese metrological verification regulation for electrochemical oxygen analyzers)
Language SupportSwitchable English/Chinese UI
Show next