BrandCOMECAUSE
ModelIN-CL2
Sampling Flow Rate2.83 L/min (0.1 cfm)
Particle Size Channels0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Counting Efficiency≥50% at 0.3 µm, ≥100% at ≥0.5 µm
Zero Count Level≤1 count/5 min
Self-Cleaning Time≤10 min
Size Accuracy±30% at 0.5 µm and 5.0 µm
Concentration Accuracy±30% at 0.5 µm
Repeatability≤±10% CV
Operating Environment15–35 °C, 10–85% RH (non-condensing)
Data Storage CapacityUp to 100,000 records
Display7-inch capacitive color touchscreen
Power SupplyInternal rechargeable Li-ion battery (16.8 V / 5 Ah, 74 Wh)
Battery Runtime≥6 h continuous sampling
Charging Time≤2 h
CommunicationWi-Fi 802.11 b/g/n, Bluetooth 4.2, USB Type-A for direct data export
Regulatory ComplianceGB/T 6167–2007, JJF 1190–2008, ISO 14644-1, FS-209E, FDA 21 CFR Part 11 (audit trail enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelIN-CL3
Sampling Flow Rate28.3 L/min (1 cfm)
Particle Size Channels0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Self-Cleaning Time≤10 min
Size Accuracy (0.5 & 5.0 µm)±30%
Concentration Accuracy (0.5 µm)±30%
Repeatability≤±10%
Operating Temperature15–35 °C
Relative Humidity Range10–85% RH
Data Storage Capacity10,000 records
Battery Life≥6 h (continuous sampling)
Power SupplyAC/DC dual-mode, 16.8 V / 15 Ah Li-ion battery
Display7-inch color capacitive touchscreen
ConnectivityWi-Fi, Bluetooth, USB flash drive support
Calibration StandardJJF 1190–2008
Performance Verification StandardGB/T 6167–2007
Cleanroom Classification SupportISO 14644-1, FS209E, GMP (static/dynamic)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
OriginShandong, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelIN-SCL
Price¥6,100
Light SourceSemiconductor Laser (Lifespan >35,000 h)
Sampling Flow Rate2.83 L/min (±5%)
Particle Size Channels0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm
Max Count Capacity35,000 particles/L (≥0.5 µm)
Counting Repeatability<10% RSD
Size Distribution Accuracy±30% at 0.5 µm
DisplayCapacitive Touch LCD
Data Storage4 GB internal (100,000 records max)
Battery3.7 V / 10,000 mAh Li-ion (≥8 h operation)
ConnectivityDual USB, Wi-Fi, Bluetooth
Environmental Operating Range0–40 °C, 10–75% RH
ComplianceJJF 1190–2008, GB/T 6167–2007, ISO 14644-1, ISO 209, EU GMP Annex 1 (dynamic/static), USP <788>, FDA 21 CFR Part 11 (audit trail enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOMECAUSE
ModelIN-CL1
Sampling Flow Rate2.83 L/min (0.1 cfm)
Particle Size Channels0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Counting Efficiency≥50% at 0.3 µm, 100% ±30% at 0.5 µm and 5.0 µm
Accuracy (Particle Concentration)±30% at 0.5 µm
Repeatability (Relative Standard Deviation)≤±10%
Zero Count Level≤1 count per 5 minutes
Self-Cleaning Time≤10 min
Operating Temperature15–35 °C
Relative Humidity10–85% RH (non-condensing)
Display7-inch color capacitive touchscreen
Data Storage CapacityUp to 100,000 records
ConnectivityWi-Fi 802.11 b/g/n, Bluetooth 4.2, USB Type-A (driver-free U-disk export)
Power SupplyRechargeable Li-ion battery (16.8 V / 5 Ah, 74 Wh)
Battery Runtime≥6 hours continuous sampling
Charging Time≤2 hours
PrinterBuilt-in high-speed thermal printer (selectable channel output)
ComplianceGB/T 6167–2007, JJF 1190–2008, ISO 14644-1, Fed Std 209E, Annex 1 of EU GMP (2022), USP <788>, FDA 21 CFR Part 11 (audit trail enabled in platform mode)