Empowering Scientific Discovery

Shandong Shanda Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-RXS
OriginShandong, China
Measurement PrincipleCompression-based Gravimetric Method (NY/T 821–2004)
Force Range0–3000 N
Resolution0.1 N
Accuracy±1% FS
Compression Speed1–300 mm/min
Dwell Time1–3600 s
Deformation Range1–70 mm
Platen Diameter110 mm
Parallelism<0.05 mm
Dimensions450 × 450 × 680 mm
Weight~45 kg
Power SupplyAC 220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
OriginShandong, China
Manufacturer TypeGeneral Distributor
Country of OriginChina
ModelSD-MS04
PriceUSD 630 (approx.)
Touchscreen5-inch color capacitive touchscreen
Operating SystemAndroid-based embedded UI
Temperature ControlPID algorithm
Temp RangeAmbient to 260 °C
Temp Accuracy±1 °C
Temp Segments1–5 programmable segments
Heating MethodQuartz infrared heating tubes
Graphite BlockHigh-density graphite core with PTFE coating
Well DimensionsØ30 mm × 160 mm depth
External Dimensions387 mm (W) × 371 mm (D) × 168 mm (H)
Power SupplyAC 220 V, 50 ±1 Hz
Rated Power1000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-QY04
TypeManual Core Sampler
OriginShandong, China
Sampling DepthUp to 2 m
Standard ConfigurationFour interchangeable coring bits (clay, loam, sand, peat), two 100 cm extension rods, one 50 cm extension rod, T-handle, soil scraper, dual wrenches, 3 m steel tape measure, protective gloves, aluminum carrying case
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-2TA
TypeManual Hydraulic Powder Press
Maximum Pressure2 Ton (25 MPa)
Piston DiameterØ32 mm
Max Piston Stroke<30 mm
Pressure GaugeAnalog Dual-Scale (MPa & Ton), Accuracy: ±1 MPa
Pressure Stability≤1 MPa/10 min
Worktable DiameterØ70 mm
Working Space90 × 120 mm
Overall Dimensions210 × 170 × 370 mm
Net Weight~11 kg
ComplianceDesigned for GLP-aligned lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-XB
Instrument TypeMulti-Function Microplate Washer
Wash Head Configuration8-channel or 12-channel dual-row removable wash head
Wash Fluid Channels1 standard (up to 4 optional)
Soaking Time Range0–24 h (hh:mm:ss adjustable)
Wash Cycles0–99
Residual Volume per Well≤1 µL
Plate CompatibilityStandard 96-well flat-bottom, U-bottom, V-bottom, and C-bottom microplates
Wash Row Selection1–12 rows (including skip-row configuration)
Liquid Delivery Pressure5 adjustable levels
Aspiration/Dispense Time0–9 s (extendable)
Plate Shaking0–24 h (hh:mm:ss), 3 intensity levels
Cleaning ModesCenter wash, dual-point wash
Program Storage200 user-defined protocols + 20 pre-stored plate profiles
Liquid Level MonitoringWaste bottle full-level alarm
Display & Interface5.6-inch color TFT touchscreen, 7×24 h continuous operation with auto power-saving mode
Power InputAC 100–240 V, 50/60 Hz
Dimensions (L×W×H)380 × 330 × 222 mm
Net Weight~9 kg
Reagent BottlesThree 2 L bottles included
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFERRITE-CHECK 140
PriceUSD 4,200 (approx.)
Measurement Range1–100 Fe% / 1–140 Ferrite Number (FN)
Accuracy±<5% of reading
Operating Temperature0–50 °C
Calibration StandardsThree NIST-traceable ferrite reference standards
Power SupplyRechargeable lithium-ion battery
ComplianceDIN EN ISO 8249:2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
OriginShandong, China
Manufacturer TypeAuthorized Distributor
ModelSD-HQMG
PriceUSD 1,390 (FOB)
Function TypeMulti-analyte Detection Platform
Sample ScopeUniversal for Cereals, Oilseeds, Feed Matrices, and Processed Food Commodities
Main ControllerARM Cortex-A7
Detection Channels≥12 independent optical channels
Display10.1-inch HD vertical capacitive touchscreen (1280×800)
Communication InterfacesIntegrated Wi-Fi (802.11 b/g/n), RJ45 Ethernet port, USB 2.0 host/device
Power SupplyDC 12 V — compatible with vehicle power outlets
Data StorageInternal eMMC (16 GB) + USB flash drive support (FAT32/exFAT)
Dimensions (W×D×H)430 × 350 × 190 mm
Net Weight5.1 kg
Light SourcePrecision imported quad-wavelength cold LED source (450 nm, 520 nm, 590 nm, 630 nm)
ProcessorRockchip RK3288 (ARM Cortex-A17 quad-core, 1.8 GHz)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-NIR-AC
Housing Material304 Stainless Steel
Measurement PrincipleNear-Infrared Reflectance Spectroscopy (NIRS) at Water-Absorbing Wavelengths (e.g., 1450 nm, 1940 nm)
Moisture Range0–100% w/w
Accuracy±0.2% w/w (under stable composition conditions)
Temperature CompensationBuilt-in, automatic
Optical PathNon-contact, reflective configuration
Spot Diameter60–75 mm
Measurement Height350 mm ± 100 mm
Optical WindowHigh-borosilicate quartz glass
Light SourceImported high-stability NIR LED/Laser
Signal ProcessingFull digital signal processing with adaptive digital filtering
Output InterfacesRS485, 4–20 mA, RS232, Ethernet (LAN), LoRa wireless
Power Supply220 VAC / 50 Hz
Power Consumption60 W
Operating Environment−40 °C to +70 °C, 5–95% RH (non-condensing)
Ingress ProtectionIP65
Optional FeaturesIntegrated temperature sensing (0–500 °C), multi-channel spectral acquisition (50 channels)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-GCT-28A
Sample Capacity28 positions
Power Supply220–230 V, 50 Hz
Operating Temperature Range5–40 °C
Relative Humidity10–85%
Temperature Control Accuracy25 °C ± 2 °C
SoftwarePC-based workstation software with real-time hardware monitoring, error code display, Excel export, color-coded batch labeling, and historical data retrieval
Optional AccessoriesRice sample preparation mill, dedicated PC, water-cooling unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda Instruments
ModelSD-BQ12T
OriginShandong, China
Instrument TypeBenchtop Integrated Spectrophotometric Analyzer for MDA Quantification in Edible Animal Fats
Detection PrincipleColorimetric Assay (Thiobarbituric Acid Reactive Substances, TBARS)
Display10.1-inch Vertical Touchscreen (Android OS, ARM Cortex-A7 RK3288 Quad-Core @ 1.88 GHz)
Optical SystemFour-Wavelength Cold Light Source per Channel (410 / 520 / 590 / 630 nm), Patented Optical Path Switching Enabling Up to 64 Wavelengths
Detection Channels≥12 Simultaneous Channels with Precision Rotating Cuvette Holder
CalibrationOne-Touch Auto-Calibration with Persistent SP Storage of Light Source Parameters
Data Storage≥200,000 Records, USB Exportable as Excel Files, Password-Protected Access
ConnectivityDual USB, RJ45 Ethernet, Bluetooth 4.2, 4G APN Module, Wi-Fi
Software ExpandabilityPre-Configured for 60+ Food Safety Assays
Compliance FrameworkDesigned for Routine Use in GLP-Compliant Food Quality Control Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-FS800Z
Measurement PrincipleClosed-path infrared gas analysis (IRGA) with dual-wavelength CO₂ sensor
CO₂ Range0–2000 ppm
CO₂ Resolution≤0.1 ppm
CO₂ Accuracy±1.5% of reading (temperature-compensated)
Air Temperature Range−20 °C to +60 °C
Relative Humidity Range0–85% RH (non-condensing)
Leaf Temperature SensorThermistor, ±0.2 °C accuracy
PAR (Photosynthetically Active Radiation) SensorSilicon photodiode, 0–3000 µmol·m⁻²·s⁻¹, ±5%
Flow Rate ControlAdjustable 0–1.0 L·min⁻¹, stability ±1% FS
Power SupplyRechargeable 8.4 V DC Li-ion battery, 15 h continuous operation (no external light source)
Display3.5″ TFT color LCD, 800×480 resolution
Data StorageInternal 16 GB flash memory (expandable to 32 GB)
InterfaceUSB 2.0 for data export
Dimensions260 × 260 × 130 mm
Weight3.25 kg
Leaf Chamber Standard Size55 × 20 mm (customizable)
Operating Environment−20 °C to +60 °C, 0–85% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-PE-T
TypeElectronic Farinograph
Power Supply220 V AC, 50 Hz
Motor Power300 W
Rotational Speed Range2–200 ±1 rpm (adjustable, real-time display)
Speed Ratio (Fast/Slow Blades)1.5:1
Torque Measurement Range0–20 N·m
Torque Sensor Accuracy≤0.3% FS
Bowl Capacity300 g
Torque Unit Calibration(9.8 ± 0.2) mN·m per Farinograph Unit (FU)
Measuring Range0–2000 FU
Water Addition Accuracy±0.2 mL (for 300 g dough)
Water Bath Pressure≤340 mbar
Water Circulation Flow Rate15 L/min (auto-fill enabled)
Dough Temperature Control30 ± 0.2 °C (PID-controlled water jacket)
Temperature Setting Range (Incubation Chamber)20–50 °C
Chamber Temperature Stability±0.2 °C
Chamber Power1200 W
Chamber Display5-inch embedded LCD touch screen
Safety FeaturesOverload protection (bowl), mechanical/electrical interlock (mixer), real-time heating element monitoring, automatic alarm on anomaly
MaterialImported stainless steel (bowl & blades), corrosion-resistant surface-treated structural components
Compliance StandardsICC 115/1, AACC 54-21, ISO 5530-1, GB/T 14614
Data HandlingMulti-file curve overlay (unlimited), custom color/name assignment, cross-brand farinogram import (legacy formats), real-time interruption & interim calculation, encrypted storage, export to CSV/Excel, GLP-compliant audit trail (via Smart Pbox integration)
SoftwareWindows 7/10 native, perpetual license, free lifetime updates
ServiceAnnual certified standard-sample calibration (with CNAS-accredited reference material certificate), two free post-warranty calibration & maintenance visits (Years 2–3), third-party performance evaluation report issued by national metrology institute
ConnectivityReal-time multi-terminal data viewing (requires Smart Pbox gateway)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda Instruments
ModelFERRITE-CHECK 240
Measurement Range0.2–100 Fe% / 0.2–140 FN
Accuracy<5%
Operating Temperature0–50 °C
Calibration Standards3 certified ferrite reference blocks
Power Supply3 × 1.5 V AA batteries or USB-C external power
ComplianceDIN EN ISO 8249
Display320 × 480 pixel color LCD touchscreen
Data Storage10,000 measurements with statistical analysis (min/max/mean/std dev)
ConnectivityBluetooth 5.0 (Android/iOS/Windows compatible)
SoftwareLima Connect (free PC/mobile application)
Dimensions150 × 85 × 35 mm
Weight320 g (including batteries)
Minimum Test AreaØ 2 mm
Resolution0.1 Fe% / 0.1 FN
Battery Life~25 h continuous operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-SW
Instrument TypeMultifunctional Soil Analyzer
DisplayLarge Backlit Chinese LCD
Power SupplyRechargeable Lithium Battery or AC Adapter
Dimensions204 × 100 × 36 mm
Measurement PrincipleFrequency Domain Reflectometry (FDR)
Soil Volumetric Water Content Range0–100% (m³/m³)
Accuracy±2% (0–50%), ±3% (50–100%)
Resolution0.1% (moisture), 0.1°C (temperature)
Temp. Range−40 to +120°C
Temp. Accuracy±0.2°C
Response Time<1 s
Stabilization Time~10 s
Sensing Volume90% influence within a 3 cm diameter × 6 cm length cylinder centered on probe
CommunicationUSB 2.0
Data LoggingManual/Automatic (configurable interval)
Optional Connectivity4G module for cloud upload to web-based agricultural platform
SoftwareFree PC-based data management suite (Excel export, curve plotting, GLP-compliant audit trail)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
OriginShandong, China
ModelSD-ND600
Wavelength Range185–910 nm
Wavelength Accuracy±1 nm
Wavelength Resolution≤1.8 nm (FWHM at Hg 546 nm)
Absorbance Accuracy±1% (7.332 Abs at 260 nm)
Absorbance Precision0.002 Abs
Sample Volume0.5–2.0 µL
Pathlength Options0.02, 0.05, 0.1, 0.5, and 1.0 mm (automatically selected)
Measurement Time≤5 s per sample
Cuvette Mode OD600 Range0–4 A
dsDNA Quantitation Range2–38,880 ng/µL
BSA Protein Range0.06–820 mg/mL
Light SourcePulsed Xenon Lamp (10-year lifetime)
Detector3648-pixel Linear CCD Array
Display7-inch Capacitive Touchscreen (Android OS)
Data ExportUSB flash drive, SD-RAM card
Optional Fluorescence ModuleEx 460 nm / Em 525 nm
Dimensions (W×D×H)270 × 210 × 196 mm
Weight3.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-FSX
OriginShandong, China
CategoryRubber & Plastic Industry–Specific Instrument
ComplianceGB/T 6030–2006
Imaging Sensor5 MP CMOS
Resolution Options640×480, 1024×768, 1280×1024, 2592×1944
InterfaceUSB 2.0
CalibrationIntegrated micrometer scale with pixel-to-µm mapping
Output FormatsPDF, PNG/JPEG, Excel (.xlsx)
Software CompatibilityWindows XP/7/10 (32/64-bit)
Image Segmentation ModesAutomated thresholding + manual ROI selection
Standard Reference LibrariesISO-aligned carbon black dispersion image library + user-customizable library
Data ExportParticle count, equivalent circular diameter (µm), projected area (µm²), grayscale histogram, particle size distribution curve, dispersion rating (0–10 scale per GB/T 6030)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSD-L2
Sample CapacityMulti-sample simultaneous measurement
Instrument TypeHeat-Flow DSC
Temperature Range−100 °C to 600 °C
Programmable Temperature ControlHeating, Isothermal, Cooling
Heating/Cooling Rate0.1–100 K/min
Scan ModesDynamic heating, dynamic cooling, isothermal hold
Temperature Accuracy±0.01 °C (typical, calibrated per ASTM E794 & ISO 11357-1)
Baseline Stability<0.5 µW over 30 min at 50 °C
Sensor Resolution0.01 µW
Temperature SensingDual independent platinum RTD sensors (furnace + sample)
Control AlgorithmAdaptive dynamic PID with FTC/STC dual-mode selection
Data Acquisition1–10 Hz user-selectable sampling rate
Communication InterfaceUSB 2.0 with auto-reconnect protocol
Atmosphere ControlDual independent gas channels (N₂, O₂, Ar, air), software-switched via solenoid valves
Calibration StandardsIndium, Zinc, Tin, and Sapphire (per ISO 11357-2)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-Z08P
OriginShandong, China
Regulatory ApprovalApproved by Ministry of Agriculture and Rural Affairs (MARA), P.R. China
Detection PrincipleReal-Time Fluorescent Quantitative Polymerase Chain Reaction (qPCR)
Target AnalyteAfrican Swine Fever Virus (ASFV) Genomic DNA
Compatible AssaysMARA-registered ASFV fluorescent qPCR kits (e.g., SD-ASF-KIT series)
Operational ModesLaboratory-based and field-deployable (battery-supported operation optional)
Throughput8 samples per run
Thermal Cycling Range4–105 °C
Fluorescence Channels4-channel excitation/emission detection (FAM, HEX/VIC, ROX, CY5)
Data OutputCt values, amplification curves, qualitative/quantitative reports compliant with MARA diagnostic guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
OriginShandong, China
ModelSD-CL9
Measurement PrincipleCoulometric Titration (per GB/T 214–2007)
Sample TypesCoal, Coke, Activated Carbon, Petroleum Coke
Temperature ControlMicroprocessor-regulated High-Temperature Furnace (up to 1150 °C)
Electrolytic CellIntegrated Dual-Platinum Electrode Cell
Display7-inch TFT LCD Touch Interface
Power SupplyAC (220 ± 22) V, 50 Hz
Max Power Consumption≤3 kW
Safety FeaturesAutomatic Silicon Carbide Tube Protection, Overcurrent Protection, Real-time Temperature Compensation
Data ManagementNon-volatile Memory Storage, USB Export, Print Support (via RS232 or USB thermal printer)
ComplianceDesigned to meet requirements of GB/T 214–2007, ASTM D3177, ISO 4293, and supports GLP-compliant audit trails when paired with optional PC software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-0SB
OriginShandong, China
Heating Power1.2 kW
Max Temperature400 °C
Temperature Uniformity±1 °C
DisplayIntelligent Digital LED
Heating Surface300 × 200 mm
Panel Thickness12 mm
Voltage220 V AC
Control Accuracy±0.1 °C (PID-controlled)
InsulationDual-layer (air gap + ceramic fiber)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanda
ModelSD-FP7450
OriginShandong, China
Detection ElementsK, Na, Li, Ca, Ba
Number of Channels5
Measurement Range0.000–999.9 / 0–65535 (arbitrary units)
Detection Limits (mmol/L)K ≤ 0.004, Na ≤ 0.008, Li ≤ 0.015, Ca ≤ 0.050, Ba ≤ 0.044
Linearity Error (mmol/L)K ≤ 0.005, Na ≤ 0.03, Li ≤ 0.021, Ca ≤ 0.075, Ba ≤ 0.066
Response Time≤ 8 s
Nebulization Rate< 6 mL/min
Stability≤ 3% RSD over 15 s
Repeatability≤ 3% RSD
Display7-inch capacitive color touchscreen
OutputConcentration values and relative emission intensity
Data OutputBuilt-in Bluetooth thermal printer, USB interface, optional PC software
Graphical DisplayReal-time calibration curve and signal trend plotting
ComplianceDesigned for routine quantitative analysis in accordance with ISO 11097:2010 (Water quality — Determination of sodium and potassium — Flame photometric method) and ASTM D1293 (Standard Test Methods for Electrical Conductivity and pH of Water)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0