| Brand | Raytech (Baoying Technology) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | Ruiyi-5S |
| Price Range | USD 28,000–42,000 (FOB Shanghai) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace (3.5 kW output) |
| Measurement Range | C: 0.00001–99.99 wt% |
| S | 0.00001–99.99 wt% |
| Sensitivity | 0.01 ppm |
| Accuracy | C: ±1.0 ppm or RSD ≤ 0.4% |
| S | ±1.0 ppm or RSD ≤ 0.9% (per certified reference materials) |
| Analysis Time | 20–40 s |
| Gas Flow Control | Digital Electronic Pressure Control (EPC) with multi-channel independent regulation |
| Detection Configuration | Dual-band IR/UV detection for sulfur (SO₂) |
| Optical Source | Solid-state pulsed IR source & solid-state UV LED |
| Detector | High-stability solid-state IR/UV detectors |
| Thermal Management | Individual thermostatic control per gas cell |
| Safety | Integrated HF leakage shielding |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TC-306 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Simultaneous O/N/H Analyzer |
| Analytical Range | Oxygen/Nitrogen/Hydrogen — Low-level mode: 0.1 ppm to 5,000 ppm |
| High-level mode | 0.5 wt% to 30 wt% |
| Accuracy | ±1 ppm or RSD ≤ 1% (for nitrogen) |
| Sensitivity | 0.01 ppm |
| Analysis Time | 120–240 s per sample (for nitrogen determination) |
| Pulse Furnace Power | 8 kW |
| Detection Principle | Inert Gas Fusion coupled with NDIR (Non-Dispersive Infrared) and TCD (Thermal Conductivity Detection) |
| Cooling System | Precision Water Temperature Control Unit |
| Footprint | Freestanding Floor Model (no lab bench required) |
| Optional Module | Remote Diagnostic Interface |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CS206 |
| Price Range | USD 14,000 – 42,000 (FOB Shanghai) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 3.5 kW High-Frequency Induction Furnace |
| Measurement Range | C: 0.0001–10 wt% |
| S | 0.0001–5 wt% (extendable to 99.99 wt% for both elements) |
| Sensitivity | 0.01 ppm |
| Precision | C: ±1.0 ppm or RSD ≤ 0.5% |
| S | ±1.0 ppm or RSD ≤ 1.0% (per certified reference materials per ISO/IEC 17025 validation protocols) |
| Analysis Time | 20–40 s per sample |
| Gas Flow Control | High-Accuracy Mass Flow Controller (MFC) |
| Combustion Atmosphere | Purified Oxygen Supply with Optional Oxygen Purification Module |
| Sample Handling | Automated Ash Removal & Multi-Stage Filtration |
| Optional Accessories | Physical Water Removal Unit, Constant-Temperature Furnace Head, Multi-Point Oxygen Injection |
| Brand | Baoying Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ONH-316 |
| Instrument Type | Oxygen/Nitrogen/Hydrogen Elemental Analyzer |
| Oxygen Range | Low-O: 0.1–5000 ppm |
| High-O | 0.5–20 wt% |
| Nitrogen Range | Low-N: 0.1–5000 ppm |
| High-N | 0.5–50 wt% |
| Hydrogen Range | 0.1–5000 ppm |
| Accuracy | O/N: ±1 ppm or RSD ≤ 1% |
| H | ±0.2 ppm or RSD ≤ 2% (relative to certified reference material uncertainty) |
| Sensitivity | 0.01 ppm |
| Analysis Time (O) | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Oxygen-Nitrogen Analyzer |
| Model | ON-316 |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Oxygen Range | 0.1 ppm – 5000 ppm (low), 0.5% – 20% (high) |
| Nitrogen Range | 0.1 ppm – 5000 ppm (low), 0.5% – 50% (high) |
| Detection Limit | 0.01 ppm |
| Accuracy | ±1 ppm or RSD ≤ 1% (O₂/N₂) |
| Analysis Time | O₂: 120–180 s |
| N₂ | 120–240 s |
| Pulse Furnace Power | 8.0 kW |
| Detector Configuration | Dual-channel NDIR for oxygen, TCD for nitrogen |
| Sample Form | Solid metals and non-metals (powders, chips, rods, pellets) |
| Compliance Support | ASTM E1019, ISO 14284, GB/T 11261, JIS G 1211 |
| Brand | Baoying Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Line | TC-306 Series |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Elemental Analyzer |
| Analytical Range | O: 0.1 ppm – 10 wt% |
| Low N | 0.1 ppm – 5000 ppm |
| High N | 0.5 – 30 wt% |
| H | 0.1 ppm – 5000 ppm |
| Analytical Precision | O & N: ±1 ppm or RSD ≤ 1.0% |
| H | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | O: 120–180 s |
| N | 120–240 s |
| H | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Model | ONH-316 |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Oxygen Range | High-O: 0.5–20 wt% |
| Low-O | 0.1–5000 ppm |
| Nitrogen Range | High-N: 0.5–50 wt% |
| Low-N | 0.1–5000 ppm |
| Hydrogen Range | 0.1–5000 ppm |
| Precision | O/N: ±1 ppm or RSD ≤ 1% |
| H | ±0.2 ppm or RSD ≤ 2% |
| Sensitivity | 0.01 ppm |
| Analysis Time | O: 120–180 s |
| N | 120–240 s |
| H | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Detector Configuration | Dual-channel NDIR for O/C (CO), Single-channel TCD for H₂ and N₂ |
| Gas Handling | EPC-controlled pneumatic architecture with independent electronic pressure control (EPC) per gas path |
| Calibration Options | Single-point, multi-point, and slope/intercept correction |
| Software Compliance | Audit trail, user-level access control, data export in CSV/Excel, optional 21 CFR Part 11 compliance module |
| Structural Design | Integrated monolithic chassis housing furnace, gas analysis module, electronics, and industrial-grade embedded PC |