Empowering Scientific Discovery

Shanghai Baoying Optoelectronics Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBaoying Technology
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelONH-316
Instrument TypeOxygen/Nitrogen/Hydrogen Elemental Analyzer
Oxygen RangeLow-O: 0.1–5000 ppm
High-O0.5–20 wt%
Nitrogen RangeLow-N: 0.1–5000 ppm
High-N0.5–50 wt%
Hydrogen Range0.1–5000 ppm
AccuracyO/N: ±1 ppm or RSD ≤ 1%
H±0.2 ppm or RSD ≤ 2% (relative to certified reference material uncertainty)
Sensitivity0.01 ppm
Analysis Time (O)120–180 s
Pulse Furnace Power8.0 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBaoying
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeOxygen-Nitrogen Analyzer
ModelON-316
Detection PrincipleInert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD)
Oxygen Range0.1 ppm – 5000 ppm (low), 0.5% – 20% (high)
Nitrogen Range0.1 ppm – 5000 ppm (low), 0.5% – 50% (high)
Detection Limit0.01 ppm
Accuracy±1 ppm or RSD ≤ 1% (O₂/N₂)
Analysis TimeO₂: 120–180 s
N₂120–240 s
Pulse Furnace Power8.0 kW
Detector ConfigurationDual-channel NDIR for oxygen, TCD for nitrogen
Sample FormSolid metals and non-metals (powders, chips, rods, pellets)
Compliance SupportASTM E1019, ISO 14284, GB/T 11261, JIS G 1211
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBaoying Technology
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product LineTC-306 Series
Instrument TypeOxygen-Nitrogen-Hydrogen Elemental Analyzer
Analytical RangeO: 0.1 ppm – 10 wt%
Low N0.1 ppm – 5000 ppm
High N0.5 – 30 wt%
H0.1 ppm – 5000 ppm
Analytical PrecisionO & N: ±1 ppm or RSD ≤ 1.0%
H±0.2 ppm or RSD ≤ 2.0%
Sensitivity0.01 ppm
Analysis TimeO: 120–180 s
N120–240 s
H120–180 s
Pulse Furnace Power8.0 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBaoying
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeOxygen-Nitrogen-Hydrogen Analyzer
ModelONH-316
Detection PrincipleInert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD)
Oxygen RangeHigh-O: 0.5–20 wt%
Low-O0.1–5000 ppm
Nitrogen RangeHigh-N: 0.5–50 wt%
Low-N0.1–5000 ppm
Hydrogen Range0.1–5000 ppm
PrecisionO/N: ±1 ppm or RSD ≤ 1%
H±0.2 ppm or RSD ≤ 2%
Sensitivity0.01 ppm
Analysis TimeO: 120–180 s
N120–240 s
H120–180 s
Pulse Furnace Power8.0 kW
Detector ConfigurationDual-channel NDIR for O/C (CO), Single-channel TCD for H₂ and N₂
Gas HandlingEPC-controlled pneumatic architecture with independent electronic pressure control (EPC) per gas path
Calibration OptionsSingle-point, multi-point, and slope/intercept correction
Software ComplianceAudit trail, user-level access control, data export in CSV/Excel, optional 21 CFR Part 11 compliance module
Structural DesignIntegrated monolithic chassis housing furnace, gas analysis module, electronics, and industrial-grade embedded PC