Empowering Scientific Discovery

Shanghai Beyu Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBEIYU TECHNOLOGIES
OriginShanghai, China
ModelHGMA390
ComplianceHJ/T 195–2005 to HJ/T 200–2005 (China EPA)
Detection TargetsNH₃-N, Total N, NO₂⁻-N, NO₃⁻-N, Kjeldahl N, S²⁻
AutomationIntegrated auto-sampler, online digestion (Total N), auto-dilution, auto-dehydration, dual-needle aspiration, optical CCD detector, long-life light source
SoftwareLIMS-ready, GLP-compliant audit trail, customizable report templates, priority-based sample queue, multi-wavelength real-time absorbance logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBEIYU TECHNOLOGIES
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSmart Unmanned System
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBEIYU TECHNOLOGIES
OriginShanghai, China
ManufacturerBEIYU Analytical Instrument Co., Ltd.
ModelCGM-206W
ComplianceGB/T 11892–1989, GB/T 5750.7–2023, GB/T 13025.7–2012, GB/T 5750.4–2023
Detection ParametersPermanganate Index (COD<sub>Mn</sub>), Iodine in Salt, Total Hardness, Chloride
Heating MethodConstant-Temperature Water Bath
Automation LevelFully Integrated Robotic Digestion–Titration System
Endpoint DetectionHigh-Resolution Machine Vision Color Recognition
Sample ThroughputUp to 30 samples per batch
Minimum Titration Volume0.02 mL
Titration Cycle Time≤2 min per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBEIYU TECHNOLOGIES
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelRainwater-Sewage Cross-Connection Intelligent Monitoring System
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBEIYU TECHNOLOGIES
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelHGMA-460
PricingUpon Request
Light SourceDeuterium Lamp
DetectorMulti-wavelength Simultaneous CCD Detector
Autosampler Capacity51 or 87 positions
Dilution RangeUp to 50× (programmable or AI-assisted auto-dilution)
Detection LimitCompliant with HJ Standards (e.g., HJ/T 195–2005, HJ/T 199–2005)
PrecisionRSD < 1% (n = 6, 0.5 mg/L NO₂⁻–N)
Analysis Time per Sample2–5 min
Dual-Channel CapabilitySimultaneous quantification of two analytes (identical or different)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0