- All
- Favorite
- Popular
- Most rated
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 |
| Internal Volume | 600 L |
| Temperature Range | −5 °C to +45 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±1.0 °C (at setpoint) |
| Temperature Fluctuation | ±0.5 °C (1σ) |
| Humidity Range | 20–95% RH |
| Humidity Uniformity | ±2% RH |
| Humidity Fluctuation | ±0.5% RH (1σ) |
| Shelf Dimensions | 630 mm × 510 mm |
| Shelf Load Capacity | 18 kg per shelf |
| Standard Shelves | 4 stainless steel shelves |
| Max. Shelves | 10 |
| Total Standard Shelf Area | 1.33 m² |
| External Dimensions (H×W×D) | 1980 × 745 × 950 mm |
| Net Weight | 175 kg |
| Power Supply | 1/N/PE, 230 V ±10%, 50 Hz, 16 A |
| Water Supply | Deionized or distilled water, 1–5 bar, conductivity <40 μS/cm |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 PLH / FitoClima 1200 PLH |
| Temperature Range | 5°C to +45°C (±0.1°C) |
| Humidity Range | 40–90% RH (±0.1% RH) |
| Light Intensity | 0–300 µmol/m²·s (up to 21,500 Lux) |
| Internal Volume | 600 L / 1200 L |
| Illumination Type | White LED or Fluorescent Plant-Growth Lighting |
| Temperature Uniformity | ±1.0°C |
| Humidity Uniformity | ±2% RH |
| Airflow Control | 1–100% adjustable (0.3–1 m/s) |
| Compliance | EN 60068-3-5, IEC 61000-6-3, EMC 2004/108/EC, MD 2006/42/CE, LVD 2006/95/CE, EN 14509-CPR 305/2011/EU, EN 13823:2010+A1:2014 |
| Brand | AICHUN |
|---|---|
| Origin | Zhejiang, China |
| Model Variants | PPS-10HD, PPS-100HD, PPS-PilotHD |
| Pump Flow Ranges | 0.001–10 mL/min (PPS-10HD), 0.01–100 mL/min (PPS-100HD), 1–400 mL/min (PPS-PilotHD) |
| Max Pressure | 20 MPa (PPS-10HD), 10 MPa (PPS-100HD), 2 MPa (PPS-PilotHD) |
| UV Detection | 200–400 nm (standard), up to 800 nm (optional) |
| Conductivity Range | 0.00–1000.00 mS/cm |
| Gradient Accuracy | ±0.6% to ±2% (model-dependent) |
| System Dimensions (W×H×D) | 482 × 661 × 432 mm |
| Weight | ≤65 kg (fully configured) |
| Power | 100–240 VAC, 50/60 Hz |
| Compliance | Audit Trail-enabled PPSN Software (21 CFR Part 11 ready) |
| Brand | Liebherr |
|---|---|
| Model | LKexv 1800 MediLine |
| Origin | Germany |
| Temperature Range | +1 °C to +15 °C (Storage), +10 °C to +30 °C (Ambient Operating Range) |
| Net Capacity | 160 L |
| Total Volume | 180 L |
| Dimensions (D×W×H) | 600 × 600 × 860 mm |
| Weight (Net) | 38 kg |
| Power Consumption | 110 W |
| Noise Level | 47 dB(A) |
| Refrigerant | R600a |
| ATEX Classification | II 3G Ex ec IIC T6 Gc |
| Compliance | EN 60068-3, IEC 61000-6-3, IEC 61000-6-2, 2014/34/EU (ATEX) |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PR Panta Plus Robotic Autosample |
| Principle | Microfluidic Capillary Electrophoresis Coupled with Intrinsic Tryptophan Fluorescence Detection (not DLS — correction based on official NanoTemper documentation) |
| Temperature Control Range | 15 °C to 110 °C |
| Sample Volume | 10 µL per capillary |
| Sample Format | Disposable fused-silica capillaries (pre-filled or user-loaded) |
| 21 CFR Part 11 Compliance | Yes |
| Dimensions | 110 cm (W) × 188 cm (H) × 90 cm (D) |
| Brand | Telstar |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Custom-Built |
| Instrument Type | Class III Biological Safety Cabinet |
| External Dimensions (L×W×H) | Customizable |
| Internal Dimensions (L×W×H) | Customizable |
| Filter Efficiency (HEPA/ULPA) | ≥99.999% at 0.12 µm |
| Brand | Liebherr |
|---|---|
| Origin | Germany |
| Model | LKUv 1613 MediLine |
| Storage Temperature Range | +3 °C to +16 °C |
| Power Consumption | 130 W |
| External Dimensions (D×W×H) | 61.8 × 60.1 × 82 cm |
| Net Weight | 43 kg |
| Net Refrigerated Volume | 132 L |
| Refrigerant | R600a |
| Noise Level | 47 dB(A) |
| Cooling System | Forced-air with dynamic auto-defrost |
| Control Interface | External digital LED display with keypad |
| Alarm System | Visual & audible power failure and fault alerts |
| Door | Insulated glass, right-hinged, self-closing, ergonomic handle |
| Interior | White coated steel walls, 4 adjustable plastic-coated wire shelves (3 height-adjustable), LED top lighting |
| Compliance | Designed for GLP-compliant environments |
| Brand | Liebherr |
|---|---|
| Origin | Germany |
| Model | HMFvh 5511 Perfection with Pharmacy Drawers |
| Storage Temperature Range | +2 °C to +8 °C (operational ambient: +10 °C to +35 °C) |
| Net Capacity | 361 L |
| Gross Volume | 588 L |
| Dimensions (D×W×H) | 769 × 747 × 1793 mm |
| Weight | 116 kg |
| Power Consumption | 190 W (rated), 475 kJ/h heat dissipation |
| Refrigerant | R600a |
| Temperature Stability | ±2 °C (max. deviation from setpoint: +1.2 K / −1.8 K) |
| Noise Level | 49 dB(A) |
| Certifications | DIN 13277, IEC 61010-2-011, IEC 61326-1 |
| Brand | Liebherr |
|---|---|
| Origin | Germany |
| Model | LKUexv 1610 MediLine |
| Storage Temperature Range | +3 °C to +16 °C |
| Power Consumption | 100 W |
| External Dimensions (D×W×H) | 61.8 × 60.1 × 82 cm |
| Net Weight | 38 kg |
| Net Refrigerated Volume | 130 L |
| Refrigerant | R600a |
| Noise Level | 47 dB(A) |
| ATEX Classification | II 3G Ex ec IIC T6 Gc |
| SmartMonitoring Capable | Yes |
| RS485 Interface | Included |
| Door Hinge | Right-hand, reversible |
| Adjustable Feet | Yes |
| Mechanical Lock | Yes |
| Energy Efficiency Class | A++ |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Model | PR Panta |
| Temperature Control Range | 15 °C–95 °C (upgradeable to 110 °C with High-Temp Module) |
| Sample Volume | 10 μL |
| Sample Introduction | Capillary or capillary array |
| Dimensions | 35 cm (L) × 51 cm (H) × 52 cm (W) |
| Brand | Telstar |
|---|---|
| Origin | Spain |
| Model | Telstar Pura 2, Pura 3, Pura 4, Pura 3+, Pura 4+ |
| Air Classification | ISO Class 5 (EU GMP Grade A) in all chambers |
| Airflow | Unidirectional laminar flow (certified per ISO 14644-1) |
| Illumination | 700 lux (test chamber), 300 lux (transfer chamber) |
| Noise Level | <70 dBA |
| Inlet Filtration | HEPA H14 (99.997% @ 0.3 µm) |
| Exhaust Filtration | HEPA H14 (99.997% @ 0.3 µm) |
| Pre-filter | E10 |
| Bio-decontamination Efficacy | ≥6-log reduction of Geobacillus stearothermophilus spores |
| Sterility Test Pump | Integrated with standard Millipore (Merck) or Sartorius filtration units |
| Non-viable Particle Monitoring | APEX P5 portable airborne particle counter (dual-channel, 0.3/0.5 µm, 3000-record memory, 3.5" color touchscreen, stainless steel 304 housing) with LMS Express software (21 CFR Part 11 compliant) |
| Viable Microbial Monitoring | Sartorius MD8 airscan with gelatin membrane filtration |
| H₂O₂ Monitoring | In-chamber single-channel sensor (0–300 ppm) |
| Validation Support | FAT/SAT/DQ/IQ/OQ/PQ documentation templates available |
| Service | Global technical support via Telstar UK |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Terrafors-IS Bacteria |
| Vessel Capacity | 15 L (3–4 kg solid substrate or 7 L liquid medium) |
| Aeration System | Stainless steel sparger with 1 mm orifices |
| CO₂ Monitoring Range | 0–10% (NDIR sensor, ±1% FS repeatability) |
| O₂ Monitoring Range | 0–25% (Zirconia sensor, ±0.5% FS repeatability) |
| Temperature Control Range | +5 °C to 80 °C (in situ sterilization up to 134 °C) |
| Rotation Speed | 0.1–10 rpm (programmable profile) |
| Air Flow Rate | 3.6–36 NL/min (rotameter-controlled with automated inlet/outlet valves) |
| Material | 316L stainless steel drum vessel |
| Sterilization | Fully automated in-situ steam sterilization via integrated INFORS steam generator |
| User Interface | Color touchscreen controller with tab-based navigation, multi-level password protection, and support for up to 24 configurable process parameters |
Show next