| Brand | -- |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gas-Pro |
| Pricing | Upon Request |
| Detection Principle | Electrochemical, Photoionization (PID), Infrared (IR) |
| Form Factor | Portable |
| Response Time (T90) | 2 s (electrochemical toxic gases), 20 s (CH₄), 10 s (O₂), 30 s (IR) |
| Repeatability | ±2% of reading (typical for H₂S, CO, SO₂, VOCs, combustibles) |
| Brand | — |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | S-16 |
| Typical Configuration | Integrated Particulate Imaging Sampler |
| Dimensions | 120 × 70 × 40 mm |
| Weight | 0.35 kg |
| Power Supply | 12 V DC |
| Power Consumption | 5 W |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–80 % RH (non-condensing) |
| Acoustic Noise | ≤10 dB(A) at 1 m |
| Battery Runtime | Up to 1.5 h (rechargeable Li-ion integrated) |
| Brand | -- |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BC-J80 |
| Quotation | Upon Request |
| Temperature Control Range & Accuracy | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.1°C (at 37°C) |
| Chamber Capacity | 80 L |
| CO₂ Control Range | 0–20% (v/v) |
| CO₂ Sensor Type | Infrared (NDIR) |
| CO₂ Recovery Time | ≤ Concentration Value × 1.2 min |
| Humidity Control | Natural Evaporation |
| Humidity Display | Yes (Capacitive Sensor) |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ≤ ±0.2°C at 37°C |
| Heating Method | Water-Jacketed |
| Internal Dimensions (W×D×H) | 420 × 400 × 550 mm |
| External Dimensions (W×D×H) | 562 × 521 × 960 mm |
| Net Weight | 51 kg |
| Gross Weight | 61 kg |
| Standard Shelving | 2 adjustable stainless-steel shelves (max 4) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 600 W |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm (HEPA-grade) |
| Communication Interface | RS-485 (1 port) |
| Data Protection | Auto-save on power interruption |
| Door Heating | Yes (anti-condensation) |
| Sterilization | Integrated UV lamp (254 nm) |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EDGE |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRM-100 |
| Instrument Type | Portable Dose Rate Meter |
| Measured Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Detector | Halogen-quenched Geiger-Müller Tube with Mica End-window (1.75″ / 45 mm diameter, density 1.5–2.0 mg/cm²) |
| Wall Material | 0.012″ stainless steel (Grade 446) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Display | 4-digit LCD with mode indicators |
| Audio Feedback | Adjustable click-per-count (muteable) |
| Visual Feedback | LED flash per count |
| Interface | 3.5 mm output jack (CMOS-compatible TTL pulses) |
| Power | One 9 V alkaline battery (typical lifespan: 2160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Brand | -- |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC1500-U |
| Price | Upon Request |
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BXP-65S |
| Price | Upon Request |
| Temperature Range | RT+5 °C to 100 °C |
| Temperature Uniformity (at 60 °C) | ±0.6 °C |
| Temperature Fluctuation (at 60 °C) | ±0.3 °C |
| 30-Second Recovery Time (at 60 °C) | 14 min |
| Heating Time to 60 °C | 16 min |
| Rated Power | 0.55 kW |
| Inner Chamber Dimensions (W×D×H) | 410 × 350 × 450 mm |
| External Dimensions (W×D×H) | 575 × 608 × 637 mm |
| Standard Shelves | 2 (max. 5) |
| Stackable | Yes (up to 2 units) |
| Interface Ports | 2 × RS-485, 1 × USB |
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KQ-500GVDV |
| Instrument Type | General-Purpose |
| Capacity | 27 L |
| Dimensions (W×D×H) | 910 × 490 × 540 mm |
| Inner Tank Dimensions | 500 × 300 × 180 mm |
| Ultrasonic Frequencies | 45 kHz / 80 kHz |
| Adjustable Ultrasonic Time | 1–999 s |
| Ultrasonic Power Output | 500 W (40–100% adjustable) |
| Heating Power | 800 W |
| Cooling Power | 350 W |
| Temperature Control Range | 0–80 °C |
| Temperature Stability | ±2 °C |
| Water Level Monitoring | Yes |
| Power Supply | 220 V / 50 Hz |
| Accessories | Stainless Steel Basket, Acoustic Lid, Electric Inlet/Drain Control |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OPTIMA 7 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Electrochemical Sensor (O₂, CO, NOₓ, SO₂, H₂S) |
| Accuracy | ≤ ±1% of full scale |
| Repeatability | ≤ 0.5% (typical, per ISO 12039 & EN 15267-3) |
| Response Time (T₉₀) | ≤ 10 s |
| Drift Stability | ≤ 1% FS/week |
| Measurable Gases | O₂, CO (low/high/very high), CO₂, NO, NO₂, NOₓ, SO₂, H₂S, flue gas temperature (0–1100 °C), ambient air temperature (0–100 °C), differential pressure (±100 hPa), static pressure (±100 hPa), flue gas velocity (3–100 m/s) |
| Display | 3.5″ color TFT LCD with LED backlight & zoom function |
| Data Storage | 16,000 internal records |
| Connectivity | Mini-USB (data transfer & charging), IrDA (infrared printer interface), optional Bluetooth 4.0 |
| Filtration | Integrated PTFE-reusable particulate filter + water separator |
| Gas Path | Stainless steel sampling probe & fittings |
| Power | Rechargeable Li-ion battery (≥6 h standard |
| Weight | < 800 g (main unit only) |
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXM-75M |
| Instrument Type | Benchtop |
| Max Temperature | 135 °C |
| Operating Pressure | 0.22 MPa (Design: 0.25 MPa) |
| Chamber Dimensions | Ø400 mm × 700 mm |
| External Dimensions | 750 mm × 800 mm × 1080 mm |
| Chamber Volume | 75 L |
| Drying Residual Moisture | <1% |
| Heating Power | 5.9 kW |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Green-Q1 |
| Pricing | Upon Request |
| Purified Water Grade | ASTM Type III / GB/T 6682–2008 Grade III |
| Resistivity | 13–17.5 MΩ·cm @ 25 °C |
| Feed Water | Municipal Tap Water |
| Operating Pressure | 0.1–0.5 MPa (1.0–5.0 kg/cm²) |
| Inlet Temperature Range | 5–45 °C |
| Output Flow Rate | 10–60 L/h |
| Power Supply | 220 VAC, 50 Hz |
| Rated Power | 50 W |
| Safety Compliance | 24 VDC Low-Voltage Control Circuit, IPX4 Splash Resistance, EMC-Compliant Design |
| Protection Features | Dry-run Protection, Full-Tank Shut-off, RO Membrane Auto-Flush Cycle, Acoustic-Optical Alarm |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical Use |
| Pump Configuration | Reciprocating Dual-Piston Isocratic or Binary High-Pressure Gradient Capable |
| Detector | UV-Vis with Variable Wavelength (VWL) Capability |
| Column Oven | PID-Controlled Temperature Regulation |
| Data Acquisition | 24-bit ADC, Low-Drift Preamp, Integrated Touchscreen Workstation (Audit Trail Optional) |
| Compliance Readiness | GLP/GMP-Aligned Architecture, FDA 21 CFR Part 11–Ready Software Framework |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Linear Ion Trap |
| Application Field | General-Purpose |
| Mass Range | m/z 50–1000 |
| Sensitivity | 0.5 ng/mL (for standard test compound under defined LC-MS conditions) |
| Resolution | ≤0.5 Da (FWHM at m/z 500) |
| Dimensions | 33.3 × 23.5 × 14.6 cm |
| Weight | 8.5 kg |
| Battery Life | Up to 2 hours (integrated Li-ion power supply) |
| Vacuum System | Dual-stage non-continuous atmospheric pressure interface (DAPI) with built-in turbomolecular pump |
| Analysis Time | <3 minutes from sample introduction to report-ready output |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Model | CCHZ-1000 |
| Measurement Principle | Light Scattering |
| Safety Rating | Exib I (150 °C) Intrinsically Safe |
| Measurement Range | 0–1000 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ±10% |
| Relative Stability Error | ±2.5% |
| Sampling Flow Rate | 2.0 L/min (±2.5%) |
| Data Storage Capacity | 50 test records |
| Dimensions | 220 × 150 × 82 mm |
| Weight | 1.9 kg |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 1600 |
| Price | Upon Request |
| Wavelength Range | 325–1100 nm |
| Wavelength Repeatability | ≤1 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.4% T |
| Optical System | Single-Beam with 1200 lines/mm Holographic Grating |
| Display | Large Backlit LCD (Wavelength Resolution: 1 nm) |
| Data Storage | Up to 100 calibration curves and 2000 measurement records |
| Interface | RS-232, USB flash drive support, Bluetooth 4.2 (for data export, mobile app sync, and optional thermal printer) |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuPoint |
| Price | Upon Request |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Plus-E2R |
| Feed Water | Municipal Tap Water |
| Inlet Pressure | 1–4 kg/cm² |
| Inlet Temperature | 5–45 °C |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 50–80 W |
| Noise Level | <50 dB(A) |
| Dimensions (W×D×H) | 500 × 400 × 580 mm |
| Weight | Not specified |
| Pure Water Output | ≥1.5–2.0 L/min |
| Pure Water Quality | Conductivity ≤1 µS/cm @25 °C (GB/T 6682–2008 Grade III) |
| Ultra-Pure Water Resistivity | 18.2 MΩ·cm @25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Endotoxin | <0.001 EU/mL |
| Microbial Count | <0.1 CFU/mL |
| Particles (>0.1 µm) | <0.1 particles/mL |
| Absorbance (254 nm, 1 cm path) | ≤0.001 |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Elite Sealer-1 |
| Detection Method | Culture-based Enzyme Substrate Method |
| Instrument Type | Semi-Automatic |
| Target Analytes | Total Coliforms, *Escherichia coli*, Thermotolerant Coliforms (Fecal Coliforms) |
| Sample Types | Drinking Water, Surface Water, Wastewater |
| Sealing Capacity | <14 sec per 51-well or 97-well Quanti-Tray®-style tray |
| Operating Noise | <48 dB(A) |
| External Casing Temperature | <40°C |
| Preheat Time | ~4 minutes |
| Service Life | >50,000 sealing cycles |
| Compliance Standards | GB/T 5750, HJ 1001 |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Time | 999.99 min (maximum runtime) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Retention Time Reproducibility | < 0.06% RSD |
| Peak Area Reproducibility | < 2% RSD |
| Power Requirement | 220 V (±10%), 47.5–63 Hz, 1500 W (100 V: 2250 W) |
| Weight | 50 kg |
| Compliance | IEC/EN 61010, UL 61010, CSA C22.2 No. 61010, CISPR 11/EN 55011 Class A, ISO 9001 |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 400 °C |
| Oven Ramp Rate | 0.1–120 °C/min |
| Cooling Mechanism | Low Thermal Mass (LTM) module enables rapid column heating and cooling |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | up to 970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | up to 970 kPa |
| Total Injector Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | 3M |
|---|---|
| Model | 6800 |
| Origin | Jiangsu, China (Manufactured under 3M global licensing & quality oversight) |
| Manufacturer Type | OEM/ODM Production Partner |
| Compliance | Meets GB 2890–2023 (China), EN 136:2023 Class 2, and compatible with NIOSH-approved 3M™ filter cartridges (e.g., 6001CN–6006CN series) |
| Weight | Approx. 510 g (without filters) |
| Facepiece Material | Medical-grade silicone |
| Field of View | ≥210° horizontal, ≥105° vertical |
| Exhalation Valve | Cold-flow, downward-oriented dual-valve design |
| Head Harness | Four-point adjustable textile strap system |
| Filter Interface | Standard 40 mm × 1/7″ threaded connection (DIN 3776) |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 3M™ Clean-Trace™ NGI |
| Pricing | Available Upon Request |
| Weight | 400 g |
| Detection Range | 0–999,999 RLU |
| Sensitivity | 10⁻¹⁵ mol ATP |
| Read Time | 10 s |
| Repeatability (CV%) | 7.4% |
| Data Storage | 10,000 test results |
| Sampling Plans | 100 plans (up to 300 points each) |
| Plan Points | 2,000 total |
| Display | 240 × 160-pixel backlit LCD |
| Battery | Rechargeable Li-ion, 36 h continuous operation |
| Auto-Diagnostics | Power-on self-test & real-time fault alerting |
| Sample Chamber | Auto-sensing lid with timeout alarm |
| Software | Trend analysis with 9 filtering modes, 5 report templates, 10 chart types, Excel export |
| User Management | Customizable role-based permissions |
| ATP Reagent Format | Pre-loaded liquid luciferin/luciferase in swab |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | SUPEC 5000A |
| Pricing | Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Laboratory Benchtop Analyzer |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Operating Pressure | 42 MPa |
| Fluidic Path Material | Full-PEEK & PTFE/PEEK/PP Non-Metallic Construction |
| Pump Configuration | Integrated Quaternary Gradient Pump with Electrolytic Eluent Generation |
| Detector Options | Conductivity, Pulsed Amperometric (PAD), UV-Vis, Fluorescence |
| Compliance Support | ASTM D4327, ISO 10304-1/-3, USP <645>, EPA Methods 300.0/317.0/321.8 |