Empowering Scientific Discovery

Shenzhen Fiteli Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMBS.SRL
OriginItaly
ModelMBS(Fitlylab) MBS-MR
Function TypeMulti-analyte Quantitative Microbial Detection
Sample TypesSolid, Liquid, Surface, Paste, Slurry
WavelengthsSimultaneous Blue-Green-Red (450 nm, 530 nm, 630 nm)
Detection Time2–10× faster than conventional culture methods
ReproducibilityHigh (CV < 5% across replicate runs)
Detection Channels8 independent, temperature-controlled wells
Sensitivity1 CFU per test
Specificity≥99.999%
ComplianceISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (testing laboratory competence), ISO/TR 13843:2000 (water microbiology)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginChina
Manufacturer TypeAuthorized Distributor
ModelTMYQ-CGR100
Detection PrincipleReflectance-based CMOS photometric quantification of colloidal gold immunochromatographic test strips
Measurement Range0–256 grayscale units (256-level reflectance intensity)
PrecisionCV ≤ 1% (repeatability under controlled ambient conditions)
Throughput≤ 60 seconds per test (including reading, calculation, and report generation)
Sample FormatSingle-strip cassette (1 test per run)
InterfaceUSB 2.0
Power SupplyDC 5 V via USB port
Operating Humidity<70% RH
Dimensions16 × 15 × 11 cm
Weight0.5 kg
Data OutputLocal storage + exportable CSV/PDF reports
Software CompatibilityWindows 7/10/11 (x64), requires external host PC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFitlylab
OriginItaly
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelRVLM
Function TypeMulti-analyte Detection Platform
Sample CompatibilitySolid, Liquid, Surface, Paste, and Slurry Samples
Optical DetectionTriple-wavelength Simultaneous Photometric Analysis
Detection Channels8 Independent Wells
Detection TimeInversely Proportional to Target Microbial Load (as low as <2 h for ≥10⁸ CFU/mL)
RepeatabilityHigh (CV <15% under standardized conditions)
Regulatory ComplianceISO 16140:2003 Validated Alternative Method
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFitlylab
OriginShenzhen, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFITLY-9616
Function TypeMulti-analyte (Simultaneous Detection of 30+ Food Contaminants & Additives)
Sample CompatibilityLiquid, Solid, Semi-solid Extracts (Homogenized or Centrifuged)
Wavelength Range410–900 nm (Fixed LED Sources at 410, 536, 595, 620 nm)
Detection Channels16-Channel Photometric Array
Photometric Repeatability≤ ±1% T
Immunoassay Detection ModeSingle-Channel CCD-Based Lateral Flow Reader (3-Megapixel, 2048×1536 Resolution, Reflective T/C Quantification)
T/C Accuracy≤ ±0.1 T/C
T/C Precision (CV)≤ 5%
Stability≤ 0.1 T/C over 10 min
Assay Time<10 s per lateral flow strip
Data Export FormatExcel (.xlsx)
ConnectivityUSB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 10/100 Mbps Ethernet
Onboard Storage32 GB SSD
RAM4 GB
CPUDual-core 1.6 GHz
Display10.2-inch Full-color Capacitive Touchscreen
Weight≤ 3.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMBS.SRL
OriginItaly
ModelMBS(Fitlylab)
Detection Channels8
WavelengthsTriple-wavelength (Blue, Green, Red)
Detection Time2–10× faster than conventional plate culture methods
RepeatabilityHigh
Sample TypesSolid, liquid, surface swabs, pastes, slurries
Regulatory ComplianceISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories), ISO/TR 13843:2000 (water quality — validation of microbiological methods)