- All
- Favorite
- Popular
- Most rated
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MBS (Fitlylab) |
| Detection Method | Chromogenic & Redox-Based Colorimetric Assay |
| Instrument Type | Fully Automated |
| Detection Targets | Total Bacterial Count, *Salmonella* spp., Total Coliforms, *Staphylococcus aureus*, *Escherichia coli*, *Listeria monocytogenes* |
| Sample Types | Compound Feeds (layer/broiler chicken, swine, duck), Animal-Origin Feeds (blood meal, meat-and-bone meal, fish meal, feather meal, whey powder), Plant-Origin Feeds (corn, bran, soybean meal, peanut meal, cottonseed meal) |
| Detection Throughput | 8 independent channels |
| Dimensions | 31.2 cm (L) × 17.5 cm (W) × 9.5 cm (H) |
| Regulatory Compliance | ISO 16140:2003 validated, ISO/IEC 17025:2005 aligned, T/SDAA 025–2021 certified |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L03 |
| Instrument Type | Benchtop |
| Detection Principle | Respirometric Colorimetric Culture-Based Assay |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Capacity | 8 Independent Channels |
| Optical Detection | Simultaneous Tri-Wavelength Photometry (450 nm, 540 nm, 630 nm) |
| Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% for target Enterobacteriaceae and E. coli |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., dairy, paste) |
| Reporting | Automated PDF generation with timestamped audit trail, GLP-compliant data storage |
| Brand | MBS S.r.l. |
|---|---|
| Origin | Italy |
| Model | MBS (Fitlylab) |
| Instrument Type | Fully Automated Microbial Detection & Quantification System |
| Detection Throughput | 8 independent channels |
| Sample Types | Liquid, solid, surface swabs, semi-solid (e.g., pastes, gels) |
| Target Microorganisms | Total viable count, *Escherichia coli*, *Staphylococcus aureus*, *Salmonella* spp., *Pseudomonas aeruginosa*, *Listeria monocytogenes*, *Enterococcus faecalis*, coliforms, fecal coliforms, *Enterobacteriaceae*, yeasts |
| Detection Sensitivity | ≥1 CFU per test |
| Specificity | ≥99.999% |
| Detection Principle | Multi-modal optical biosensing based on real-time monitoring of redox-mediated chromogenic response in VL detection vials |
| Regulatory Compliance | ISO 16140:2003 (validation of alternative methods), ISO/IEC 17025:2017 (testing laboratory competence), ISO/TR 13843:2000 (water microbiology) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N-4L |
| Price Range | USD 150–2,500 (FOB Yokohama) |
| Test Target | Somatic Cell Count (SCC) & Electrical Conductivity (EC) Correlates for Subclinical Mastitis |
| Automation Level | Semi-Automatic |
| Analysis Time | ≤3 seconds per quarter |
| Detection Principle | Dual-Parameter Impedance Spectroscopy & Conductivity Ratio Analysis |
| Repeatability | CV ≤3.2% (n=20, pooled quarter milk samples) |
| Accuracy | ±0.1 unit in normalized conductivity ratio (dimensionless index) |
| Brand | MBS.SRL |
|---|---|
| Country of Origin | Italy |
| Model | MBS(Fitlylab) |
| Detection Method | Chromogenic Enzyme-Substrate Assay Coupled with Redox-Based Colorimetric Monitoring |
| Target Microorganisms | Escherichia coli, Staphylococcus aureus, Salmonella spp., Pseudomonas aeruginosa, Listeria monocytogenes, Enterococcus faecalis, Total Viable Count, Coliforms, E. coli (specific), Fecal Coliforms, Enterobacteriaceae, Yeasts |
| Sample Types | Solid, Liquid, Surface Swabs, Paste, Slurry |
| Detection Speed | 2–10× faster than conventional culture-based methods |
| Throughput | 8 independent, temperature-controlled detection channels |
| Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% |
| Compliance | ISO 16140:2003 (Microbiology of Food and Animal Feeding Stuffs — Validation of Alternative Methods), ISO/IEC 17025:2005 (General Requirements for the Competence of Testing and Calibration Laboratories) |
| Brand | CSC |
|---|---|
| Origin | USA |
| Model | Bostwick Consistometer |
| Instrument Type | Flow-Through Consistometer (Capillary-Free Gravitational Flow Viscometer) |
| Construction | Stainless Steel Body with Electrolytically Polished 2 mm Steel Ramp |
| Sample Volume | 75 mL |
| Dimensions (L×W×H) | 14 in × 3.5 in × 5.5 in |
| Scale Resolution | 0.5 cm graduations |
| Leveling | Dual adjustable leveling screws + bubble level |
| Flow Gate | Spring-loaded instantaneous release gate |
| Compliance | SNT 1036–2002 (China Export Standard for Tomato Paste), ASTM D1824–22 (Standard Test Method for Consistency of Semisolid Materials), ISO 10985:2021 (Foodstuffs — Determination of Flow Behaviour Using Bostwick Consistometer) |
| Brand | Fitlylab |
|---|---|
| Origin | Guangdong, China |
| Model | W1 |
| Material | Fully Stainless Steel (316L-grade components) |
| Filter Cup Diameter | φ47 mm or φ50 mm |
| Membrane Pore Size | 0.22 µm or 0.45 µm |
| Configuration | Triple-station with independent valve control per station |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min, steam) |
| Compliance | Designed for ISO 7218, ASTM D5673, and USP <61> microbiological testing workflows |
| Includes | Stainless steel filtration cups, stainless steel support screens, stainless steel manifold支架, stainless steel isolation valves, anodized aluminum clamps, silicone tubing, overflow-prevention collection flask, vacuum pump interface |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | MBS(Fitlylab) MBS-MR |
| Function Type | Multi-analyte Quantitative Microbial Detection |
| Sample Types | Solid, Liquid, Surface, Paste, Slurry |
| Wavelengths | Simultaneous Blue-Green-Red (450 nm, 530 nm, 630 nm) |
| Detection Time | 2–10× faster than conventional culture methods |
| Reproducibility | High (CV < 5% across replicate runs) |
| Detection Channels | 8 independent, temperature-controlled wells |
| Sensitivity | 1 CFU per test |
| Specificity | ≥99.999% |
| Compliance | ISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (testing laboratory competence), ISO/TR 13843:2000 (water microbiology) |
| Brand | Royal Biotech GmbH |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RVLM |
| Price | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PD-30 |
| Price Range | USD 1,400 – 2,800 |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMYQ-CGR100 |
| Detection Principle | Reflectance-based CMOS photometric quantification of colloidal gold immunochromatographic test strips |
| Measurement Range | 0–256 grayscale units (256-level reflectance intensity) |
| Precision | CV ≤ 1% (repeatability under controlled ambient conditions) |
| Throughput | ≤ 60 seconds per test (including reading, calculation, and report generation) |
| Sample Format | Single-strip cassette (1 test per run) |
| Interface | USB 2.0 |
| Power Supply | DC 5 V via USB port |
| Operating Humidity | <70% RH |
| Dimensions | 16 × 15 × 11 cm |
| Weight | 0.5 kg |
| Data Output | Local storage + exportable CSV/PDF reports |
| Software Compatibility | Windows 7/10/11 (x64), requires external host PC |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L02 |
| Price Range | USD 14,000 – 70,000 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal Oxidative-Reductive Kinetic Assay with Tri-wavelength Photometric Monitoring |
| Sample Throughput | 8 Independent Channels |
| Detection Limit | 1 CFU per test |
| Specificity | ≥99.999% |
| Sample Types | Liquid, Solid, Surface Swab, Paste, Aerosol Condensate |
| Regulatory Compliance | Validated for Food, Water, Environmental & Clinical Surveillance per ISO, EN and FDA-aligned protocols |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Fitlylab-L22 |
| Detection Range | Sample-dependent (validated per ISO 16140:2003) |
| Detection Time | 2–10 hours |
| Detection Throughput | 1 CFU per assay |
| Sampling Frequency | Single-point measurement per vial |
| Origin | Germany |
|---|---|
| Manufacturer | JEL GmbH |
| Type | STAV II |
| Power Supply | 230 V AC, 50 Hz |
| Vibration Frequency | 250 ± 15 cycles/min |
| Vibration Amplitude | 3.0 ± 0.1 mm |
| Available Cylinder Volumes | 50, 100, 250, 500, 1000 mL (DIN 53194 compliant) |
| Net Weight | 9 kg |
| Control Interface | Red illuminated panel with integrated counter (5-digit, programmable), conical locking mechanism for cylinder fixation, low-noise AC motor |
| Origin | Assembled in Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | MULTISKAN ASCENT |
| Pricing | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | PLS-24 / PLS-96G / PLS-96 |
| Measurement Range | 0.000–3.000 Abs (PLS-24), 0.000–4.000 Abs (PLS-96G/96) |
| Wavelength Range | 400–1100 nm |
| Optical Channels | 2 (PLS-24), 8 (PLS-96G/96) |
| Read Time (Single Wavelength) | 25 s (PLS-24), 5 s (PLS-96G/96) |
| Wavelength Accuracy | ±2.0 nm |
| Spectral Bandwidth | 8 ± 1.0 nm |
| Absorbance Repeatability (CV) | ≤0.5% |
| Channel Uniformity | ≤0.02 A |
| Stray Light | ≥2.0 A at 510 nm (50.0 g/L NaNO₂) |
| Absorbance Drift | ≤±0.005 A over 20 min (at 492 nm, ~1.000 A) |
| Absorbance Linearity Error | ±0.010 A (0.000–2.000 A), ±0.050 A (2.000–3.500 A) |
| Dimensions | 370 × 245 × 170 mm (PLS-24), 420 × 305 × 170 mm (PLS-96G/96) |
| Weight | 6 kg (PLS-24), 9 kg (PLS-96G/96) |
| Data Storage | 100 assay methods (PLS-24), 200 assay methods + 105 plates (10,000 results) (PLS-96G/96) |
| Interface | RS-232 serial port |
| Display | Color TFT touchscreen (PLS-96G), color TFT with membrane keypad (PLS-24/96) |
| Detection Modes | Absorbance, qualitative, quantitative, enzyme inhibition rate |
| Filter Selection | Manual (PLS-24), automatic (PLS-96G/96) |
| Built-in Thermal Printer | Yes (PLS-24/96), optional external printer support (PLS-96G) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fitlylab-L04 |
| Price Range | USD 13,500 – 68,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | HMBX |
| Price | USD 11,800 (FOB) |
| Brand | Fitlylab |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RVLM |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Solid, Liquid, Surface, Paste, and Slurry Samples |
| Optical Detection | Triple-wavelength Simultaneous Photometric Analysis |
| Detection Channels | 8 Independent Wells |
| Detection Time | Inversely Proportional to Target Microbial Load (as low as <2 h for ≥10⁸ CFU/mL) |
| Repeatability | High (CV <15% under standardized conditions) |
| Regulatory Compliance | ISO 16140:2003 Validated Alternative Method |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L22 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal optical biosensing based on real-time redox-mediated chromogenic kinetics |
| Sample Throughput | 8 independent, temperature-controlled channels |
| Detection Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% for target analytes |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., dairy, paste, slurry) |
| Readout Method | Simultaneous tri-wavelength photometric monitoring (450 nm, 530 nm, 630 nm) |
| Report Output | PDF with audit trail, timestamped raw kinetic curves, and quantitative CFU/mL or CFU/g results |
| Software | Fitlylab v5.x (Windows-based, multilingual, GLP-compliant data management) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AH-30A |
| Price | USD 3,750 (FOB) |
| Measurement Time | ≤30 s/sample |
| Parameters | Fat, Protein, Non-Fat Solids, Density, Freezing Point, Water Adulteration, Lactose, Ash, pH, Conductivity, Temperature |
| Fat Range | 0.00–25.00% (±0.08%) |
| Protein Range | 2.00–7.50% (±0.10%) |
| Non-Fat Solids Range | 3.00–15.00% (±0.10%) |
| Density Range | 1.015–1.040 g/cm³ (±0.0003 g/cm³) |
| Freezing Point Range | −0.3 to −0.7 °C (±0.001 °C) |
| Water Adulteration Range | 1–70% (±1%) |
| Lactose Range | 0.00–7.00% (±0.10%) |
| Ash Range | 0.4–1.5% (±0.05%) |
| pH Range | 0–14 (±0.05) |
| Conductivity Range | 3–14 mS/cm (±0.05 mS/cm) |
| Temperature Range | 1–40 °C (±1 °C) |
| Operating Ambient | 0–50 °C |
| Sample Temperature | 10–35 °C |
| Relative Humidity | 30–80% RH |
| Power Supply | AC 220 V / DC 12 V |
| Dimensions | 400 × 300 × 300 mm |
| Display | Backlit English LCD |
| Output | Integrated thermal printer (English interface) |
| Cleaning | Fully automated dual-loop rinsing and aspiration system |
| Brand | Fitlylab |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FITLY-9616 |
| Function Type | Multi-analyte (Simultaneous Detection of 30+ Food Contaminants & Additives) |
| Sample Compatibility | Liquid, Solid, Semi-solid Extracts (Homogenized or Centrifuged) |
| Wavelength Range | 410–900 nm (Fixed LED Sources at 410, 536, 595, 620 nm) |
| Detection Channels | 16-Channel Photometric Array |
| Photometric Repeatability | ≤ ±1% T |
| Immunoassay Detection Mode | Single-Channel CCD-Based Lateral Flow Reader (3-Megapixel, 2048×1536 Resolution, Reflective T/C Quantification) |
| T/C Accuracy | ≤ ±0.1 T/C |
| T/C Precision (CV) | ≤ 5% |
| Stability | ≤ 0.1 T/C over 10 min |
| Assay Time | <10 s per lateral flow strip |
| Data Export Format | Excel (.xlsx) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 10/100 Mbps Ethernet |
| Onboard Storage | 32 GB SSD |
| RAM | 4 GB |
| CPU | Dual-core 1.6 GHz |
| Display | 10.2-inch Full-color Capacitive Touchscreen |
| Weight | ≤ 3.0 kg |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Models | 12-Hole / 20-Hole / 30-Hole |
| Price | USD 140 (FOB) |
| Key | Brand: MBS.SRL |
|---|---|
| Origin | Italy |
| Type | Semi-Automatic Microbial Detection System |
| Throughput | 8 independent channels |
| Filter Cup Capacity | 11 mL |
| Filter Membrane Diameter | 47 mm |
| Detection Principle | Multi-modal (respirometric + enzymatic + immunogenic + nucleic acid–enhanced colorimetric assay) |
| Certified to ISO 16140 | 2003 (validation of alternative methods in food microbiology) and ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories) |
Show next