- All
- Favorite
- Popular
- Most rated
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MBS (Fitlylab) |
| Detection Method | Chromogenic & Redox-Based Colorimetric Assay |
| Instrument Type | Fully Automated |
| Detection Targets | Total Bacterial Count, *Salmonella* spp., Total Coliforms, *Staphylococcus aureus*, *Escherichia coli*, *Listeria monocytogenes* |
| Sample Types | Compound Feeds (layer/broiler chicken, swine, duck), Animal-Origin Feeds (blood meal, meat-and-bone meal, fish meal, feather meal, whey powder), Plant-Origin Feeds (corn, bran, soybean meal, peanut meal, cottonseed meal) |
| Detection Throughput | 8 independent channels |
| Dimensions | 31.2 cm (L) × 17.5 cm (W) × 9.5 cm (H) |
| Regulatory Compliance | ISO 16140:2003 validated, ISO/IEC 17025:2005 aligned, T/SDAA 025–2021 certified |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L03 |
| Instrument Type | Benchtop |
| Detection Principle | Respirometric Colorimetric Culture-Based Assay |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Capacity | 8 Independent Channels |
| Optical Detection | Simultaneous Tri-Wavelength Photometry (450 nm, 540 nm, 630 nm) |
| Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% for target Enterobacteriaceae and E. coli |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., dairy, paste) |
| Reporting | Automated PDF generation with timestamped audit trail, GLP-compliant data storage |
| Brand | MBS S.r.l. |
|---|---|
| Origin | Italy |
| Model | MBS (Fitlylab) |
| Instrument Type | Fully Automated Microbial Detection & Quantification System |
| Detection Throughput | 8 independent channels |
| Sample Types | Liquid, solid, surface swabs, semi-solid (e.g., pastes, gels) |
| Target Microorganisms | Total viable count, *Escherichia coli*, *Staphylococcus aureus*, *Salmonella* spp., *Pseudomonas aeruginosa*, *Listeria monocytogenes*, *Enterococcus faecalis*, coliforms, fecal coliforms, *Enterobacteriaceae*, yeasts |
| Detection Sensitivity | ≥1 CFU per test |
| Specificity | ≥99.999% |
| Detection Principle | Multi-modal optical biosensing based on real-time monitoring of redox-mediated chromogenic response in VL detection vials |
| Regulatory Compliance | ISO 16140:2003 (validation of alternative methods), ISO/IEC 17025:2017 (testing laboratory competence), ISO/TR 13843:2000 (water microbiology) |
| Brand | MBS.SRL |
|---|---|
| Country of Origin | Italy |
| Model | MBS(Fitlylab) |
| Detection Method | Chromogenic Enzyme-Substrate Assay Coupled with Redox-Based Colorimetric Monitoring |
| Target Microorganisms | Escherichia coli, Staphylococcus aureus, Salmonella spp., Pseudomonas aeruginosa, Listeria monocytogenes, Enterococcus faecalis, Total Viable Count, Coliforms, E. coli (specific), Fecal Coliforms, Enterobacteriaceae, Yeasts |
| Sample Types | Solid, Liquid, Surface Swabs, Paste, Slurry |
| Detection Speed | 2–10× faster than conventional culture-based methods |
| Throughput | 8 independent, temperature-controlled detection channels |
| Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% |
| Compliance | ISO 16140:2003 (Microbiology of Food and Animal Feeding Stuffs — Validation of Alternative Methods), ISO/IEC 17025:2005 (General Requirements for the Competence of Testing and Calibration Laboratories) |
| Brand | Fitlylab |
|---|---|
| Origin | Guangdong, China |
| Model | W1 |
| Material | Fully Stainless Steel (316L-grade components) |
| Filter Cup Diameter | φ47 mm or φ50 mm |
| Membrane Pore Size | 0.22 µm or 0.45 µm |
| Configuration | Triple-station with independent valve control per station |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min, steam) |
| Compliance | Designed for ISO 7218, ASTM D5673, and USP <61> microbiological testing workflows |
| Includes | Stainless steel filtration cups, stainless steel support screens, stainless steel manifold支架, stainless steel isolation valves, anodized aluminum clamps, silicone tubing, overflow-prevention collection flask, vacuum pump interface |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L02 |
| Price Range | USD 14,000 – 70,000 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal Oxidative-Reductive Kinetic Assay with Tri-wavelength Photometric Monitoring |
| Sample Throughput | 8 Independent Channels |
| Detection Limit | 1 CFU per test |
| Specificity | ≥99.999% |
| Sample Types | Liquid, Solid, Surface Swab, Paste, Aerosol Condensate |
| Regulatory Compliance | Validated for Food, Water, Environmental & Clinical Surveillance per ISO, EN and FDA-aligned protocols |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Fitlylab-L22 |
| Detection Range | Sample-dependent (validated per ISO 16140:2003) |
| Detection Time | 2–10 hours |
| Detection Throughput | 1 CFU per assay |
| Sampling Frequency | Single-point measurement per vial |
| Origin | Assembled in Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | MULTISKAN ASCENT |
| Pricing | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | PLS-24 / PLS-96G / PLS-96 |
| Measurement Range | 0.000–3.000 Abs (PLS-24), 0.000–4.000 Abs (PLS-96G/96) |
| Wavelength Range | 400–1100 nm |
| Optical Channels | 2 (PLS-24), 8 (PLS-96G/96) |
| Read Time (Single Wavelength) | 25 s (PLS-24), 5 s (PLS-96G/96) |
| Wavelength Accuracy | ±2.0 nm |
| Spectral Bandwidth | 8 ± 1.0 nm |
| Absorbance Repeatability (CV) | ≤0.5% |
| Channel Uniformity | ≤0.02 A |
| Stray Light | ≥2.0 A at 510 nm (50.0 g/L NaNO₂) |
| Absorbance Drift | ≤±0.005 A over 20 min (at 492 nm, ~1.000 A) |
| Absorbance Linearity Error | ±0.010 A (0.000–2.000 A), ±0.050 A (2.000–3.500 A) |
| Dimensions | 370 × 245 × 170 mm (PLS-24), 420 × 305 × 170 mm (PLS-96G/96) |
| Weight | 6 kg (PLS-24), 9 kg (PLS-96G/96) |
| Data Storage | 100 assay methods (PLS-24), 200 assay methods + 105 plates (10,000 results) (PLS-96G/96) |
| Interface | RS-232 serial port |
| Display | Color TFT touchscreen (PLS-96G), color TFT with membrane keypad (PLS-24/96) |
| Detection Modes | Absorbance, qualitative, quantitative, enzyme inhibition rate |
| Filter Selection | Manual (PLS-24), automatic (PLS-96G/96) |
| Built-in Thermal Printer | Yes (PLS-24/96), optional external printer support (PLS-96G) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fitlylab-L04 |
| Price Range | USD 13,500 – 68,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | HMBX |
| Price | USD 11,800 (FOB) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L22 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal optical biosensing based on real-time redox-mediated chromogenic kinetics |
| Sample Throughput | 8 independent, temperature-controlled channels |
| Detection Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% for target analytes |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., dairy, paste, slurry) |
| Readout Method | Simultaneous tri-wavelength photometric monitoring (450 nm, 530 nm, 630 nm) |
| Report Output | PDF with audit trail, timestamped raw kinetic curves, and quantitative CFU/mL or CFU/g results |
| Software | Fitlylab v5.x (Windows-based, multilingual, GLP-compliant data management) |
| Key | Brand: MBS.SRL |
|---|---|
| Origin | Italy |
| Type | Semi-Automatic Microbial Detection System |
| Throughput | 8 independent channels |
| Filter Cup Capacity | 11 mL |
| Filter Membrane Diameter | 47 mm |
| Detection Principle | Multi-modal (respirometric + enzymatic + immunogenic + nucleic acid–enhanced colorimetric assay) |
| Certified to ISO 16140 | 2003 (validation of alternative methods in food microbiology) and ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L06 |
| Certification | ISO 16140:2003 (Microbiology of Food and Animal Feeding Stuffs – Validation of Alternative Methods) |
| ISO/IEC 17025 | 2005 (General Requirements for the Competence of Testing and Calibration Laboratories) |
| Detection Principle | Multi-modal optical biosensing based on real-time redox-mediated chromogenic kinetics |
| Sample Throughput | 8 independent, temperature-controlled channels |
| Detection Sensitivity | ≥1 CFU per assay |
| Specificity | ≥99.999% for *Salmonella* spp. |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., milk, paste, homogenates) |
| Detection Time | 4–12 h (vs. 48–96 h for conventional culture) |
| Wavelengths | Simultaneous triple-wavelength photometric detection (450 nm, 540 nm, 630 nm) |
| Data Output | Automated PDF report with timestamped kinetic curves, CFU/mL or CFU/g quantification, pass/fail flagging against user-defined thresholds |
| Software | Fitlylab v3.x (Windows-based, multilingual, audit-trail enabled) |
| [Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Multiscan MK3 |
| Optical Range | 340–750 nm (standard configuration: 405, 450, 492, 630 nm) |
| Absorbance Range | 0.000–3.500 A |
| Resolution | 0.001 A |
| Accuracy | ±1% (0–2.0 A) |
| Precision (CV) | <0.2% or ≤0.001 Abs at 0.5 A |
| Read Time | ≤5 seconds per 96-well plate |
| Plate Shaking | Linear vibration, 3 adjustable speeds |
| Dimensions | 140 × 420 × 320 mm (W × D × H) |
| Weight | 11 kg |
| Interface | RS-232 serial port, parallel printer port |
| Light Source | Quartz tungsten halogen lamp |
| Display | 2 × 20-character LCD |
| Keyboard | 30-key membrane keypad |
| Power Supply | 220–240 V, 50/60 Hz] |
| Brand | MBS.SRL |
|---|---|
| Country of Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fitlylab-L01 |
| Instrument Type | Fully Automated Microbial Detection & Enumeration System |
| Detection Principle | Multi-modal optical monitoring of redox-mediated chromogenic response in sealed VL detection vials |
| Throughput | 8 independent parallel detection channels |
| Detection Speed | 2–10× faster than conventional culture-based methods |
| Sensitivity | ≥1 CFU per test |
| Specificity | ≥99.999% |
| Compliance | ISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories) |
| Sample Forms | Liquid, solid, surface swab, semi-solid (paste/gel), aerosol-derived (via impinger or filtration) |
| [Brand | Royal Biotech GmbH |
|---|---|
| Origin | Germany |
| Model | RVLM |
| Compliance | ISO 16140:2003 validated |
| Sample Volume | 0.1–1.0 g or mL |
| Throughput | 8 independent channels |
| Detection Principle | Integrated enzymatic (β-glucuronidase), immunological (antigen capture), and microbial growth-based colorimetric assay |
| Sensitivity | ≥1 CFU (theoretical limit) |
| Specificity | ≥99.999% (theoretical limit) |
| Incubation Temperature Range | 30–44 °C (microbe-specific) |
| Readout Method | Optical colorimetric kinetics (qualitative/semi-quantitative visual |
| Software Compatibility | Windows XP/Vista/7 |
| Power Supply | AC adapter + replaceable laptop-grade Li-ion battery] |
| Brand | Royal Biotech GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RVLM |
| Price | USD 36,500 (approx.) |
Show next