Empowering Scientific Discovery

Shimadzu (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product LineHMA-4200 Series
Measurement PrinciplesColorimetric Spectrophotometry per ISO 11969 / GB/T 7467–1987 (for Cr(VI)), ISO 11045 / GB/T 7475–1987 (for Total Cr, Cu, Ni)
Detection Range0–2 mg/L (Cr(VI), Total Cr), 0–3.5 mg/L (Total Cu), 0–10 mg/L (Total Ni)
Accuracy≤±5% FS
Repeatability≤±5% RSD
Linearity Error≤±5% FS
Span Drift≤±5% over 24 h
Zero Drift≤±3% (Cr(VI), Total Ni), ≤±5% (Total Cu)
Minimum Measurement Cycle20 min (Cr(VI)), 50 min (Total Cr, Cu, Ni)
Calibration ModeManual or Automatic (with standard solution dispensing module)
Output InterfaceRS-232 serial port and isolated 4–20 mA analog output
MTBF≥1440 h
Power Supply220 VAC ±10%, 50 Hz ±5%
Dimensions (H×W×D)1550 × 500 × 420 mm
Enclosure RatingIP54 (indoor installation)
ComplianceDesigned to support ISO/IEC 17025-compliant QA/QC workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelUVM-4020
Instrument TypeOnline Analyzer
Measurement PrincipleWeighted Multi-Wavelength Ultraviolet Absorption Spectrophotometry (243 nm, 254 nm, 265 nm, 275 nm, 290 nm)
CalibrationAutomatic zero/span calibration with standard solutions (optional)
Measurement Ranges0–400 SAC, 0–200 SAC, 0–80 SAC
Cycle Time1 min (minimum), adjustable from 10 to 720 min
Output ParametersCOD, BOD, TOC, SAC
Preloaded Conversion Formulas30 built-in empirical equations
Auto-Cleaning IntervalUser-configurable timer-based internal tubing flush
Power Supply220 V ±10 V, 50/60 Hz, ~100 VA
Operating Environment5–40 °C, ≤90% RH (non-condensing, non-freezing)
Sample Flow Rate1–2 L/min
Max. Sample Pressure≤50 kPa
InstallationIndoor only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer TypeManufacturer
Product OriginDomestic
ModelTP-4110
Measurement ParameterTotal Phosphorus (TP)
Instrument TypeOnline Analyzer
Measurement PrinciplePotassium Persulfate UV Oxidation–Molybdenum Blue Spectrophotometry
Detection Range0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L
Measurement Cycle60 min
Sample PretreatmentHigh-speed rotary homogenizer + automatic backwash filtration using tap water
Automatic CleaningDistilled water flush at user-defined intervals
Power Supply220 V ±10 V, 50/60 Hz, ≤300 VA
Operating Temperature1–40 °C
Relative Humidity≤90 % RH (non-condensing)
InstallationIndoor only
ComplianceDesigned for continuous compliance monitoring per China’s HJ 353–2019, HJ 354–2019, and HJ 355–2019 standards for online water quality analyzers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelCOD-4200
Instrument TypeOnline Analyzer
Measurement PrincipleHigh-Temperature Potassium Dichromate Digestion with Photometric Detection
Standard Range30–4000 mg/L COD
Accuracy±10% at ≥100 mg/L
Repeatability≤±5%
Zero Drift±5 mg/L
Span Drift≤±5%
Resolution<1 mg/L
Minimum Measurement Cycle20 minutes
Calibration ModesManual and Automatic
Communication InterfacesRS-232, 4–20 mA (bidirectional)
Power Supply220 VAC ±10%, 50 Hz ±5%
Power Consumption~100 VA
Dimensions500 mm × 420 mm × 1550 mm
Weight~90 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelTOC-4200
Instrument TypeOnline TOC Analyzer
Oxidation MethodHigh-Temperature Catalytic Combustion at 680 °C
Detection PrincipleNDIR (Non-Dispersive Infrared) CO₂ Detection
Measurement Range0–1 ppm to 0–20,000 ppm (auto-ranging)
Cycle TimeMinimum 4 minutes per analysis
Carrier GasHigh-Purity Nitrogen (≥99.99%, 250–300 kPa)
Power Supply90–260 V AC, 50/60 Hz, 6 A
Power Consumption200 W (at operating temperature)
Operating Environment0–40 °C, ≤90% RH, Indoor Installation Only
CalibrationAuto-zero & span calibration
Sample HandlingIntegrated high-speed rotary homogenizer
Internal CleaningScheduled distilled-water flush of fluidic pathways
InterfaceFull-color capacitive touchscreen
CommunicationMODBUS RTU over RS-232/RS-485, 4–20 mA analog output, digital I/O
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelTNP-4200
Measurement ParametersTotal Nitrogen (TN), Total Phosphorus (TP)
Instrument TypeOnline Analyzer
Measurement PrincipleAlkaline Potassium Persulfate UV Oxidation – UV Absorbance (TN)
Detection RangeTN: 0–2 / 5 / 10 / 20 / 50 / 100 / 200 mg N/L
TP0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L
Cycle Time60 min (simultaneous TN & TP)
Power Consumption≤300 VA (AC 100–240 V, 50/60 Hz)
Operating EnvironmentIndoor use only
Sample PretreatmentHigh-speed rotary homogenizer with auto backwash filter
Auto-CleaningScheduled distilled water flush of fluidic pathways
Auto-CalibrationDual-point (zero & span) using standard solutions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelTOC-L
Instrument TypeLaboratory TOC Analyzer
Oxidation MethodHigh-Temperature Catalytic Combustion Oxidation (680 °C)
Measurement Range4 μg/L to 30,000 mg/L
Detection PrincipleCO₂ quantification via Non-Dispersive Infrared (NDIR) detection after catalytic combustion
Power SavingsUp to 36% vs. prior generation (8 h/day, 5 days/week)
Footprint ReductionWidth reduced from ~440 mm to 340 mm
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0