| Model | Nexis GC-2030 Enhanced Edition |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤3.4 min (at 22 °C ambient) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Total Injector Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Brevis GC-2050 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Carrier Gas Pressure Range & Control | 0–1035 kPa (7 programmable pressure segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | GC×GC-qMS |
| Price Range | USD 135,000 – 205,000 (FOB Japan) |
| Application Scope | General-Purpose Analytical Laboratory |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Petrochemical Accessories Kit |
| Instrument Type | Laboratory Gas Chromatograph Accessories |
| Application Field | Petroleum & Petrochemical Industry |
| Key Components | G-VAPORIZER Flash Vaporizer |
| Compliance | Designed for ASTM D1319, D5769, D6730, ISO 6974, and USP <467> residual solvent methods |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC-2014 |
| Price Range | USD 21,000 – 28,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +10°C to 420°C (–50°C to 420°C with liquid CO₂ cooling) |
| Maximum Ramp Rate | 250°C/min |
| Cooling Rate | 300°C → 50°C in <6 min |
| Carrier Gas Flow Range & Control | 0–1250 mL/min |
| Carrier Gas Pressure Range & Control | 0–1035 kPa |
| Injector Max Operating Temperature | 420°C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Oven Program Segments | Up to 20 (including cooling ramps) |
| Injector Simultaneous Installation | Up to 3 units |
| Detector Simultaneous Installation | Up to 4 units |
| Detector Compatibility | FID, TCD, ECD, FPD, FTD (capillary & packed column variants) |
| Display | 240 × 320-pixel graphical LCD (30 chars × 60 lines) |
| Dimensions (GC Main Unit) | 400 × 690 × 607 mm (W × H × D) |
| Weight | 48 kg (GC-2014AF configuration) |
| Power Supply | AC 200 V, 1800 VA, 50/60 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Micro Methanizer |
| Instrument Type | Laboratory Gas Chromatograph Accessory |
| Application Scope | Universal for Carbon-Containing Compound Analysis |
| Core Configuration | FID-Integrated Catalytic Converter (Jetanizer & Polyarc Reactor Options) |
| Catalyst Chemistry | Nickel-Free for Jetanizer |
| Linear Dynamic Range | ppm to % (CO/CO₂) |
| Installation Time | <5 min (FID nozzle replacement only) |
| Oxygen Tolerance | Up to 21% O₂ in carrier gas stream |
| Sulfur Resistance | Stable operation with ≤100 ppb H₂S |
| Conversion Efficiency | ≥99% for >200 carbon-containing species including aldehydes, carboxylic acids, halocarbons, and heteroatom-containing compounds |
| Regulatory Alignment | Compatible with USP <621>, ASTM D1945, ISO 8573-5, and GLP-compliant data integrity workflows |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Oven Ramp Rate | 0.01–250 °C/min |
| Oven Cool-Down Time | ~3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1300 mL/min He |
| Carrier Gas Pressure Control | 0–1035 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min He |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MDGC/GCMS |
| Application Scope | General-Purpose Analytical Chemistry |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | G-VAPORIZER |
| Price Range | USD 3,900 – 5,600 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph Accessory |
| Application Field | Petrochemical & Coal Chemical Industries |
| Maximum Operating Temperature | 230 °C |
| Maximum Sample Inlet Pressure | 9 MPa (1305 psi) |
| Heating Zone | Heated Transfer Line with Active Temperature Control |
| Inlet Configuration | Dual-Mode (Gas/Liquid) with Solenoid Valve Integration |
| Communication Interface | GC-System Synchronization via Digital I/O or RS-232 |
| Surface Treatment | Passivated Stainless Steel Tubing |
| Filtration | Integrated Particulate Filter (5 µm) |
| Brand | Shimadzu |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | GC Smart (GC-2018) |
| Application Scope | General-purpose analysis |
| Detector Options | FID, TCD |
| Inlet Options | Packed column inlet, Split/Splitless capillary inlet |
| Maximum Configurable Inlets | 2 |
| Maximum Configurable Detectors | 2 |
| Integrated Autosampler Power Supply | Yes (for AOC-20i) |
| Software | LabSolution LE |
| Connectivity | USB 2.0, Ethernet (10/100BASE-TX) |
| Compliance Support | ASTM D3606, D5504 |
| Brand | Shimadzu |
|---|---|
| Origin | Imported (Manufactured in Suzhou, China under Shimadzu Global Quality Standards) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +10 °C to 400 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | From 300 °C to 50 °C in <6 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–970 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GC-2010 Pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | –250 to +250 °C/min (programmable) |
| Oven Cooling Rate | 450 °C → 50 °C in ≤3.4 min |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7-segment programming) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7-segment programming) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1250 mL/min |