- All
- Favorite
- Popular
- Most rated
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Resolution | 0.9 cm⁻¹ |
| Scan Speed | 45 scans/min (at 4 cm⁻¹ resolution) |
| Signal-to-Noise Ratio | 30,000:1 |
| Form Factor | Compact, Dual-Orientational (Horizontal/Vertical Placement) |
| Sample Compartment | Large-volume chamber compatible with Shimadzu and third-party FTIR accessories |
| Software | IR Pilot with 23 preconfigured application workflows, qualitative identification module, and pass/fail foreign material analysis module |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SolidSpec-3700i |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) / InGaAs / Cooled PbS |
| Wavelength Range | 165–3300 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | Variable |
| Stray Light | <0.00005% T (at 340 nm, NaNO₂) |
| Sample Compartment Internal Dimensions | 900 W × 700 D × 350 H mm |
| Max Sample Size | 700 W × 560 D × 40 H mm |
| Automation | Motorized wavelength scanning, optional XY automated sample stage |
| Software | LabSolutions UV-Vis |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RM-3000 |
| Instrument Type | Handheld Portable Raman Spectrometer |
| Spectral Range | 200–3000 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Spatial Resolution | 0.22 mm |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | <1 cm⁻¹ |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Imported |
| Model | UV-1900i Plus |
| Optical Design | Dual-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.02% (at 220 nm and 340 nm) |
| Automation | Motorized Wavelength Scanning, Auto-Power-On/Wake-Up, Wireless Data Transfer (Wi-Fi), PictBridge-Compatible Printing |
| Software | LabSolutions UV-Vis DB/CS (with Audit Trail, User Management, and 21 CFR Part 11 Compliance Features) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IRXross |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 55,000:1 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | PDA-5000 |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Number of Channels | 24 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Floor-Standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Microscope |
| Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio | 30,000:1 |
| Optical Magnification Range | 330× continuous (macro to micro, 10 mm × 13 mm to 30 µm × 40 µm) |
| Detector | Liquid Nitrogen-Cooled MCT (Mercury Cadmium Telluride) |
| Automation | Fully Motorized XYZ Stage with Digital Image-Based Auto-Targeting |
| Software | IRsolution with Integrated Chemical Imaging and Automated Contaminant Identification Algorithm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | IRTracer-100 |
| Instrument Type | Laboratory Benchtop |
| Instrument Class | Fourier Transform Type |
| Price Range | USD 35,000 – 70,000 (FOB Japan) |
| Key Performance | SNR up to 60,000:1 (DLATGS detector, 4 cm⁻¹, 2,200 cm⁻¹ region, 1-min scan) |
| Spectral Resolution | 0.25–16 cm⁻¹ (user-selectable) |
| Acquisition Speed | Up to 20 spectra/sec (at 16 cm⁻¹) |
| Detector Options | DLATGS (standard), MCT (optional, liquid N₂-cooled) |
| Software Platform | LabSolutions IR v2.x or later |
| Compliance | FDA 21 CFR Part 11, PIC/S Annex 11, GLP/GMP-ready audit trail & electronic signature support |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PQY-01 |
| Wavelength Range | 250–800 nm |
| Detection System | Photodiode Array (PDA) |
| Optical Configuration | Dual-Wavelength Simultaneous Acquisition |
| Automation Level | Fully Automated Wavelength Scanning & Photonic Flux Calibration |
| Photon Flux Calibration Standard | NIST-Traceable Radiometric Power Meter |
| Measurement Throughput | <10 min per sample for absorbed photon quantification |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PDA-8000 |
| Configuration | Floor-standing |
| Excitation Source | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RF-6000 |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth (Slit Width) | 1.0–20.0 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity (S/N Ratio) | ≥1000:1 (RMS) |
| Wavelength Range | Excitation 200–900 nm, Emission 200–900 nm |
| Scan Speed | Up to 60,000 nm/min |
| Light Source | Long-life Xenon Lamp (2000 h typical lifetime) |
| Detector | Broadband Photomultiplier Tube (PMT), extended to 900 nm |
| Dispersion Element | Dual grating + interference filter system |
| Quantum Yield Measurement | Supported (absolute and relative) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | AA-7800 |
| Price Range | USD 42,000 – 85,000 (FOB China) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | AIRsight |
| Price Range | USD 270,000 – 405,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICPE-9800 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Argon Purity Requirement | ≥99.95% |
| Minimum Argon Flow (Eco Mode) | 5 L/min |
| UV Spectral Range | 165–190 nm |
| Optical System | Two-Dimensional Cross-Dispersion with Sealed Vacuum Chamber |
| Detector | High-Resolution Megapixel CCD |
| Torch Configuration | Vertical Dual-View Design |
| Software Platform | ICPESolution v3.x with Automatic Interference-Free Wavelength Selection |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UV-2600i Plus / UV-2700i Plus |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1400 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.02 nm |
| Spectral Bandwidth | Variable (selectable) |
| Stray Light | < 0.005% T |
| Maximum Absorbance Range | UV-2600i Plus — up to 6 Abs |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner with 1800 grooves/mm grating |
| Spectral Bandwidth | 0.2, 0.7, 1.3, 2.0 nm (4-step automatic switching) |
| Optical System | Dual-beam for flame mode |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Simultaneous deuterium lamp (BGC-D₂, 185–430 nm) and fast self-reversal (BGC-SR, 185–900 nm) |
| Lamp Holder | 6-position, dual-lamp operation (1 pre-heating) |
| Dimensions (AA-7000F) | 700 × 588 × 714 mm, 72 kg |
| Dimensions (AA-7000G) | 700 × 580 × 538 mm, 65 kg |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Operating Environment | 10–35 °C, 20–80% RH (≤70% above 30 °C) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | UV-3600i Plus |
| Instrument Architecture | Double-beam |
| Automation Level | Automatic Wavelength Scanning |
| Wavelength Range | 185 nm to 3300 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AIRsight |
| Instrument Type | Laboratory Benchtop System |
Show next