Surface & Interface Property Testing
Filter
Showing 61–90 of 203 results
| Brand | Benteng |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BZL-6 |
| Price Range | USD 1,400–7,000 (est.) |
| Measurement Range | 2–200 mN/m |
| Resolution | 0.1 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 10–30 °C (typical test temperature: 25 °C) |
| Temperature Display Accuracy | ±0.1% of reading |
| Measurement Method | Du Noüy Ring Method |
| Repeatability | ±0.3% |
| Power Consumption | 20 VA |
| Dimensions (W×D×H) | 185 × 260 × 360 mm |
| Net Weight | 10.3 kg |
| Operating Humidity | 20–75% RH |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 700 |
| Measurement Range | 1–2000 mN/m |
| Resolution | 0.0001 mN/m (static), 0.001 mN/m (dynamic) |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring, Wilhelmy Plate, Dynamic Contact Angle, CMC, Surface Free Energy, Washburn Penetration, Adhesion Force, Sedimentation, Density |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 701 |
| Measurement Range | 1–2000 mN/m |
| Resolution (Surface Tension) | 0.001 mN/m |
| Accuracy (Surface Tension) | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.05–0.1 µN |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Motorized Stage Speed | 0.01–500 mm/min |
| Stage Positioning Accuracy | 0.016 µm |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Weight | 13–16 kg |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 702ET |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Compliance | ASTM D971, IEC 62961 |
| Density Measurement Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Sample Stage Speed | 0.01–500 mm/min |
| Positional Accuracy | ±0.26 µm |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −20 to +200 °C |
| Temperature Display Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Weight | 11 kg |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flex |
| Instrument Type | Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 320 mm |
| Maximum Sample Size (L×W×H) | 763 × 230 × 435 mm |
| Stage Load Capacity | 26 kg |
| Imaging System | USB 3.0 Digital Camera with 8× Zoom, High-Intensity Monochromatic LED Illumination |
| Image Resolution | 1936 × 1216 (optional Theta Flow high-speed camera available) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow with 3D Topography Module |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited (L) × 100 mm (W) × 320 mm (D) |
| Max Sample Size | Unlimited (L) × 320 mm (W) × 22 mm (H) |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow HPC High Pressure Chamber |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0.1–179.9° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited × 100 mm × 320 mm |
| Maximum Sample Size | 765 mm × 230 mm × 435 mm |
| Stage Load Capacity | 29 kg |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Pressure Control | Automated via integrated precision pump |
| Temperature Range | Ambient to elevated temperatures (optional sub-ambient cooling available) |
| Chamber Design | Piston-driven high-pressure cell with corrosion-resistant wetted materials (e.g., Hastelloy C-276, sapphire windows) |
| Fluid Handling | Dual-path intelligent injection valve for direct syringe-based dispensing and in-line cleaning without pump priming |
| Surface Activity Preservation | Piston displacement maintains constant bulk-phase surfactant concentration during pressure ramping |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow |
| Instrument Type | Benchtop Dynamic Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Imaging System | USB 3.0 Digital Camera with 8× Optical Zoom & High-Power Monochromatic LED Illumination |
| Sample Stage Dimensions | 765 mm × 230 mm × 435 mm (W × D × H) |
| Maximum Sample Weight | 29 kg |
| Environmental Monitoring | Integrated Temperature & Humidity Sensors |
| Software Platform | OneAttension v4.x with Audit Trail, CFR 21 Part 11 Compliance Options |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow Wafer |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | Contact angle, surface tension, interfacial tension, surface free energy |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Sizes | 2", 3", 4", 5", 6", 8", 12" wafers |
| Image Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m (derived via pendant/sessile drop analysis) |
| Maximum Sample Diameter | 12-inch silicon wafer |
| Stage Load Capacity | 500 g |
| Automated Functions | Motorized XYZ translation + programmable rotation (0–360°), four independent software-controlled dispensers with disposable tips |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-precision mode) |
| Surface & Interfacial Tension Range | 0.01–2000 mN/m |
| Surface & Interfacial Tension Accuracy | ±0.1 mN/m (standard), ±0.01 mN/m (high-precision mode) |
| Camera Resolution | 1936 × 1216 pixels |
| Sample Stage Dimensions (L×W×H) | 495 × 130 × 310 mm |
| Max. Sample Weight Capacity | 5 kg |
| Image Magnification | Fixed optical path with high-magnification telecentric lens system |
| Measurement Modes | Static CA, Advancing/Receding CA, Roll-off Angle, Surface Free Energy (Owens-Wendt, Wu, van Oss), Interfacial Tension, Batch Analysis, Roughness-Corrected CA, Single-Fiber CA |
| Software | OneAttension v4.x (FDA 21 CFR Part 11 compliant audit trail option available) |
| Brand | Bruker |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Hysitron TS 77 Select Nanoindenter |
| Instrument Type | Nanoindenter |
| Maximum Indentation Depth | µm |
| Effective Load Range | 100 nN – 10 mN |
| Load Resolution | <1 nN |
| Displacement Range | 1 nm – 10 µm |
| Displacement Resolution | <0.05 nm |
| Maximum Friction Force | 10 mN |
| Indenter Tip Geometry | Berkovich (triangular pyramid), Cube-corner, Flat-punch, and Custom trapezoidal tips |
| Thermal Drift | <0.05 nm/s |
| Brand | CIQTEK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | H-Sorb 4600 |
| Measurement Method | Static Volumetric Method |
| Temperature Range | –196 °C to 350 °C (standard heating jacket |
| Pressure Range | Ultra-High Vacuum (≤5×10⁻⁶ Pa with extended molecular pump) to 200 bar |
| Sample Tube Material | Electropolished 316L Stainless Steel with Micro-Welded Construction |
| Sealing | VCR Metal-to-Metal Face Seal |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSA100 |
| Price Range | USD 68,000 – 136,000 |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 100 × 100 mm (adjustable height) |
| Optical Magnification | 0.7–4.5× (motorized zoom lens) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Temperature Control Range | −30 to +400 °C (with optional thermostatted stages) |
| Humidity Control | Integrated chamber (10–95% RH, ±2% RH stability) |
| Imaging System | High-speed monochrome CMOS camera (1024 × 1024 px, 12-bit dynamic range, up to 300 fps) |
| Software Platform | ADVANCE v4.x with audit trail, user management, and 21 CFR Part 11 compliance modules |
| Brand | SMS |
|---|---|
| Origin | United Kingdom |
| Model | DVS Adventure |
| Instrument Type | Dynamic Vapor Sorption Analyzer |
| Mass Resolution | ±0.01 µg |
| Temperature Range | 5–85 °C |
| Relative Humidity Range | 0–98 %RH |
| Sample Mass Capacity | 1 mg to 5000 mg |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software | DVS Insight v5.x with audit trail, method validation support, and 21 CFR Part 11 optional modules |
| Brand | EMTEC |
|---|---|
| Origin | Germany |
| Model | emtec PDA.C 02 with WSD 02 Module |
| Power Supply | 230 V, 50 Hz / 115 V, 60 Hz |
| Sample Dimensions | ≥210 mm × (60 ± 0.5) mm |
| Instrument Weight | 8.5 kg |
| Measurement Resolution | ±0.013% strain |
| Reproducibility | ±0.05% absolute strain (0–3% range), ±5% relative error at low elongation |
| Time Resolution | Starts recording from first contact (t = 0 ms), data capture interval ≤100 ms |
| Max. Measurable Wet Expansion | 25% |
| Compliance | Designed for ISO 12625-9, TAPPI T 492 om-22, and ASTM D726-15 aligned test protocols |
| Brand | KRÜSS |
|---|---|
| Origin | Germany |
| Model | BPT Mobile |
| Surface Tension Range | 10–100 mN/m |
| Resolution | 0.1 mN/m |
| Surface Age Range | 10–30,000 ms |
| Temperature Measurement Range | 0–100 °C |
| Display | 5-inch IPS touchscreen (480 × 854 px) |
| Battery Life | Up to 10 hours |
| Dimensions (W × D × H) | 85 × 55 × 220 mm |
| Weight (without accessories) | 600 g |
| Measurement Principle | Bubble Pressure Method |
| Brand | SHNTI (Distributor) |
|---|---|
| Origin | Switzerland |
| Model Series | FT-RS / FT-FS / FT-S / FT-G / FT-UMS1000 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 1 µm |
| Effective Load Range | 5 nN – 10 mN |
| Load Resolution | 1 nN |
| Displacement Range | ±100 µm |
| Displacement Resolution | 5 nm |
| Maximum Friction Force | 1 mN |
| Indenter Tip Types | Berkovich, Cube-Corner, Flat Punch, Spherical (customizable) |
| Thermal Drift | <0.1 nm/s (at 25 °C, stabilized environment) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | ST30 |
| Instrument Type | Micro/Nano Scratch Tester |
| Maximum Indentation Depth | 1000 µm |
| Effective Load Range | 0.01–30 N |
| Load Resolution | 0.7 µN |
| Displacement Range | 100 mm |
| Displacement Resolution | 0.01 nm |
| Maximum Friction Force | 50 N |
| Indenter Type | Rockwell Indenter |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TMIX |
| Light Source | 880 nm NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Interval | 20 s |
| Compliance | Designed for GLP-compliant stability assessment |
| Brand | GFM |
|---|---|
| Country of Origin | Germany |
| Model | 3D Step Height & Surface Defect Profilometer |
| Measurement Principle | Laser Stripe Phase Projection with DSP-Based Real-Time Image Processing |
| Measurement Range (X/Y/Z) | 13 × 8 × 5 mm |
| Measurement Uncertainty | (2 + L/1000) µm (L in µm) |
| Vertical Resolution | 1 µm |
| Working Distance | 107 mm |
| Scan Time per Frame | 3 s |
| Point Cloud Density | 360,000 points/frame |
| Operating Temperature | 5–40 °C |
| Light Source | Blue LED |
| Optical Path | High-Angle Illumination Design |
| Software | Dedicated Scratch & Step Analysis Suite with Polynomial/Gaussian/Mean Filtering |
| Brand | Grace |
|---|---|
| Origin | USA |
| Model | M9170/M9180 |
| Confining Pressure Range | 0–10,000 psi (690 bar) |
| Pore Pressure Range | 0–500 psi (34 bar) |
| Core Diameter | 1.5″ (1″ optional) |
| Core Length | Up to 3″ |
| Porosity Range | 0–60% |
| Permeability Range | 0.0005 mD to 10 D |
| Test Gases | N₂, He, dry air |
| Measurement Principles | Boyle’s Law (porosity), Unsteady-state Pulse Decay (low-perm), Steady-state Flow (high-perm) |
| Klinkenberg Correction | Yes |
| Data Output Format | CSV |
| Software Platform | Windows-based native application |
| Construction | 316 Stainless Steel pressure vessels |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Brand | Grand |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Temperature Range | Ambient to 140 °C (oil bath) |
| Pressure Range | High vacuum to 69 MPa |
| Key Features | Constant-temperature gas manifold, sensor calibration protocol to eliminate non-zero adsorption artifacts, ultra-low leak rate design (<1×10⁻⁹ mbar·L/s) to prevent spurious adsorption signals |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCPMFY-A |
| Price | USD 1,700 (approx.) |
| Touchscreen | 7-inch capacitive HMI |
| Measurement Principle | Controlled compression-deformation-relaxation cycle with laser-displacement tracking and load-cell feedback |
| Compression Speed | (1000 ± 100) mm/min |
| Platen Diameter | 203 mm |
| Support Plate Perforation | Ø6.5 mm, 20 mm pitch |
| Sample Dimensions | 380 × 380 × 100 mm |
| Initial Preload Force | 4.5 N |
| Deformation Target | 75% of initial thickness |
| Dwell Time | 60 s |
| Recovery Threshold | Re-engagement of 4.5 N preload force |
| Time Resolution | 0.01 s |
| Thickness Measurement Accuracy | ±1 mm |
| Load Cell Capacity | 1000 N |
| Compliance | GB/T 26392–2011, ASTM D3574–2008 Section 12 (Recovery Time for Slow-Recovery Foams) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMQS-I.2 |
| Price | USD 2,250 (FOB Beijing) |
| Power Supply | 220 V AC / 50 Hz |
| Vertical Travel Range | 0–800 mm |
| Optical Sensor Accuracy | ±1 mm |
| Optical Sensor Range | 10–1000 mm |
| Temperature Probe Range | 0–500 °C (Accuracy: ±0.5% FS) |
| Pressure Sensor Range (Optional) | 0–500 N |
| Sample Cup ID | 100 mm |
| Sample Cup Height | 200 mm |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-made) |
| Model | HKCA-15 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Measurement Accuracy | ±0.1° |
| Sample Stage Dimensions | 100 mm × 100 mm |
| Optical Magnification | 0.75×–4.5× (Parfocal Zoom) |
| Surface/Interfacial Tension Measurement Range | 0–180° (via Sessile Drop Method) |
| Surface/Interfacial Tension Resolution | 0.01 mN/m (derived from contact angle and known liquid properties) |
| Imaging System | High-Resolution CMOS Camera with Real-Time Capture |
| Analysis Methods | Circle Fitting, Baseline-Circle Fitting |
| Image Processing Modes | Manual & Auto Edge Detection |
| Stage Translation | Vertical ±50 mm, Horizontal ±60 mm, Microscope Translation: ±10 mm (X-axis) |
| Overall Dimensions | 160 mm (W) × 880 mm (D) × 720 mm (H) |
| Frame Construction | Aerospace-Grade Aluminum Base with Four-Point Leveling Feet |
| Brand | Hokuto Instruments (HOKUTOcn) |
|---|---|
| Origin | Dongguan, Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Class | Video-Based Optical Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.001° |
| Sample Stage Dimensions | 130 × 150 mm (customizable) |
| Max Sample Size | 200 (W) × ∞ (L) × 30 (H) mm |
| Surface/Interfacial Tension Range | 0.1–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Tilt Mechanism | Motorized whole-stage tilting for advancing/receding angle and roll-off angle measurement |
| Imaging | Sony 1/1.8″ progressive-scan CMOS sensor (1280 × 1024), 80 fps, rolling shutter |
| Illumination | Imported industrial-grade cold white LED backlight (400–760 nm), PWM-dimmable, >50,000 h lifetime |
| Software | CA V2.0 Static/Dynamic Contact Angle & Surface Energy Analysis Suite (Windows 10 64-bit) |
| Calibration | Traceable certified angle standards (5°, 8°, 30°, 60°, 90°, 120° optional) |
| Data Management | Audit-trail-enabled reporting (PDF/Excel/Word), GLP-compliant history database, role-based user access (operator/admin) |
| Brand | Hokuto Instruments (HOKUTOcn) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | CA/300 |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Meter |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.001° |
| Standard Sample Stage Size | 300 × 300 mm (customizable up to 1000 × 1000 mm) |
| Maximum Sample Dimensions | 300 mm (W) × ∞ (L) × 50 mm (H), customizable |
| Surface/Interfacial Tension Range | 0.1–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Surface/Interfacial Tension Resolution | 0.001 mN/m |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SA-9650 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Gas Adsorption) |
| Number of Analysis Stations | 1–3 |
| Specific Surface Area Range | 0.10 to >2000 m²/g |
| Repeatability | RSD < 1% |
| Brand | HPHC |
|---|---|
| Origin | Beijing, China |
| Model | CM8310 Series |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Gas Inlet Ports | 8 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.001 °C |
| Heating Rate | 1 °C/min |
| Pressure Range | Atmospheric |
| Test Capabilities | TPD, TPR, TPO, Pulse Chemisorption (Metal Dispersion), Vapor Adsorption, BET Single-Point Surface Area, Multi-Component Competitive Adsorption |
| Detector | Tungsten-Rhenium Alloy Thermal Conductivity Detector (TCD) |
| TCD Count | 1 |
| Mass Flow Controllers | 2 |
| Exhaust Flow Meter | 1 |
| Electric 6-Port Valve | 1 |
| Electric 4-Port Valves | 2 |
| Furnace Control | Dual-point (“Bed Temp” & “Furnace Temp”) |
| Sample Temperature Sensing | Independent RTD or Thermocouple |
| Internal Line Insulation | Up to 300 °C |
| Gas Flow Range | 5–100 SCCM |
| Tubing Material | 1/8″ SS316 |
| Optional Accessories | Integrated Vapor Generator (Continuous & Pulsed Modes), Customizable LOOP Volumes (≥3 Options), Cold Trap (1), Forced-Air Cooling System (1) |
