Surface & Interface Property Testing
Filter
Showing 121–150 of 203 results
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | Roll-to-Roll |
| Price Range | USD 13,500 – 27,000 |
| Brand | Labthink |
|---|---|
| Model | MXD-02 |
| Application | Static & Kinetic COF Measurement for Urological Catheters, Guidewires, and Medical Tubing under Physiological Hydration Conditions |
| Temperature Control | 37 °C ± 0.5 °C (Water-Bath Immersion) |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Slider Mass | 200 g (standard, silicone-coated) |
| Travel Distance | 70 mm / 150 mm |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Ambient Requirements | 23 ± 2 °C, 20–70 % RH |
| Compliance | Designed for ASTM F2624-22, ISO 8536-3, USP <1031>, and GLP-aligned validation protocols |
| Brand | MAIERIC |
|---|---|
| Model | MTIA-A |
| Measurement Frequency Range | 0.05 Hz – 10 MHz |
| Basic Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | Up to 10,000 samples/sec |
| Resolution | 0.05 Hz (frequency), 0.01 V (voltage) |
| Excitation Voltage Range | 0.02 V – 2 V |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel (up to 128 channels, 16 active simultaneously) |
| Impedance Parameters | Z, R, X, L, C, D, Q, θ |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Analysis Features | Equivalent Circuit Modeling, Time-Domain Sequence Plotting, Multi-Channel Compensation, Sweep & Multi-Channel Mapping |
| Brand | Makeway |
|---|---|
| Model | MKW-KP002 |
| Origin | Shanghai, China |
| Application Environment | Ambient, Controlled Atmosphere, or Humidity-Regulated Conditions |
| Work Function Resolution | 1–3 meV (2 mm tip), 5–10 meV (50 µm tip) |
| Tip-to-Sample Distance Control | Down to ≤400 nm |
| Digital Control Architecture | Full FPGA-based digital signal processing with ON (Off-Null) detection, Height Regulation (HR), Parallel Plate (PP) oscillation mode, Signal Averaging (SA), Work Function Averaging (WA), Quick-Change Tip (QT), Faraday Cage (FC), TTL Output Channel (OC), Data Export to Excel/Origin (DE) |
| Brand | Makeway |
|---|---|
| Origin | Shanghai, China |
| Model | MKW-KP004 |
| Probe Count | 9 integrated Kelvin probes |
| Maximum Substrate Size | 300 mm (12-inch) wafers |
| Energy Resolution | < 1 meV |
| Probe Tip Diameter | 1.4 mm (metal) |
| Angular Position Sensing Resolution | 1° |
| X-Axis Motorized Travel | > 100 mm, Positioning Accuracy: ±50 µm |
| Rotational Axis | Motorized silicon wafer stage with integrated optical encoder |
| Dead-Zone Minimization | Optimized for small wafers and wafer fragments |
| Work Function Calibration Reference | Integrated HOPG or Au reference |
| Environmental Monitoring | Onboard USB-connected temperature & humidity sensor |
| Faraday Cage | Fully integrated gold-plated steel enclosure |
| Software Control | Scriptable measurement engine supporting user-defined protocols |
| Data Output | Full-wafer, half-wafer, quarter-wafer, line-scan, and point-mode surface potential maps |
| Compliance Framework | Designed for GLP-aligned lab environments |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCP-HT450 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCP-T610 |
| Pricing | Upon Request |
| Measurement Method | Four-Point Probe, Constant Current Method |
| Resistance Range | 10⁻³ Ω to 10⁷ Ω |
| Supported Test Currents | 100 mA, 10 mA, 1 mA, 100 µA, 10 µA, 1 µA, 0.1 µA |
| Accuracy | ±2.0% ±20 digits (10⁻³–10⁻¹ Ω), ±1.0% ±5 digits (10⁰–10² Ω), ±1.0% ±3 digits (10³–10⁴ Ω), ±0.5% ±3 digits (10⁵ Ω), ±1.0% ±3 digits (10⁶ Ω), ±2.0% ±5 digits (10⁷ Ω) |
| Power Supply | AC 85–264 V, 47–63 Hz |
| Battery Backup | ~3 years (rechargeable lithium battery) |
| Probe Types | ASP, ESP, PSP, BSP, QPP, TFP (all four-point collinear probes) |
| Standard Probe | MCP-TP03P (4-pin, needle length 5 mm, tip radius 0.37 mm) |
| Calibration Checker | MCP-TRF1 (1 Ω standard resistor for ASP/ESP probes) |
| Optional Probes | MCP-TP08P (4 mm needle, Ø2 mm tip, 240 g/needle spring force), MCP-TP06P (1.5 mm needle, 0.26 mm tip radius, 70 g/needle), MCP-TPQPP (2.2 mm needle, 0.37 mm tip radius, 210 g/needle), MCP-TP05P (1 mm needle, 0.15 mm tip radius, 50 g/needle), MCP-TFP (dedicated thin-film probe) |
| Data Interface | RS232C |
| Dimensions & Weight | 330 × 270 × 88 mm, 3.4 kg |
| Display | 5.7-inch LCD |
| Data Storage Capacity | 1000 measurements |
| Preloaded Measurement Files | 18 user-configurable test setups |
| Brand | Mecwins |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SCALA |
| Pricing | Available Upon Request |
| Brand | Micro Materials |
|---|---|
| Origin | United Kingdom |
| Model | NanoTest Vantage |
| Instrument Type | Integrated Nanoindentation & Scratch Tester |
| Maximum Indentation Depth | >10 mm |
| Effective Load Range | 500 mN |
| Load Resolution | 3 nN |
| Displacement Range (XY) | 100 µm × 100 µm |
| Displacement Resolution | 0.002 nm |
| Maximum Friction Force | >250 mN |
| Indenter Types | Diamond, Cubic Boron Nitride (c-BN), Sapphire |
| Thermal Drift | <0.005 nm/s |
| Brand | Micro Materials |
|---|---|
| Origin | United Kingdom |
| Model | Xtreme |
| Instrument Type | Nanoindentation and Scratch Tester |
| Displacement Resolution | 0.002 nm |
| Indenter Types | Diamond, Boron Nitride, Sapphire |
| Thermal Drift | < 0.005 nm/s |
| Vacuum Level | 10⁻⁷ mbar |
| Temperature Range (Vacuum) | −40 °C to 1000 °C |
| Load Frame | Electromagnetic Actuation |
| Load Resolution | 3 nN |
| Repeatability Accuracy | < 0.4 µm |
| Compliance | ISO 14577, ASTM E2546 |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoPore V Series |
| Pore Size Range | 3 nm – 1100 µm |
| Pressure Range | 0.2 – 50 psia |
| Intrusion/Extrusion Volume Precision | < 0.1 µL |
| Compliance | ASTM D4284, D4404, D6761 |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELCAT II |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Number of Gas Inlets | 8 (Pre-treatment), 3 (Carrier), 8 (Pulse), 8 (Mixing) |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±1 °C |
| Heating Rates | 50–500 °C at 70 °C/min |
| Pressure Range | Atmospheric |
| Key Functions | TPD, TPR, TPO, TPRx, Pulse Chemisorption, Single-point BET, Breakthrough Curve Analysis |
| Gas Compatibility | He, Kr, N2, Ar, O2, H2, CO, CO2, NH3, H2O, NO, SO2, H2S, CH3OH, C2H5OH, Toluene, Benzene, and other reactive/volatile species |
| Thermal Conductivity Detector (TCD) | Quad-wire configuration with W–Re or gold-plated tungsten filaments |
| resolution | 1 μV |
| Mass Flow Controllers (MFCs) | 3–4 units |
| Sample Volume Capacity | 0–1 cm³ |
| Pulse Loop Volumes | 0.3 cm³, 1 cm³, or custom |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BELMASS II |
| Instrument Type | Chemisorption Analyzer with Integrated Online MS Detection |
| Gas Inlet Ports | Up to 16 |
| Temperature Stability | ±0.001 °C |
| Supported Techniques | TPD, TPR, TPS, Pulse Titration, BET Surface Area Analysis (via coupled gas dosing) |
| Mass Range | 1–200 amu |
| Detector | Faraday Cup / Continuous Dynode Electron Multiplier (C-SEM) |
| Minimum Detectable Concentration | <1 ppm (gas-dependent) |
| Scan Speed Options | Auto, 0.01–10 sec per amu (selectable) |
| Detection Channels | Up to 16 simultaneous mass channels |
| Sample Interface | Heated capillary transfer line (up to 300 °C), integrated dry scroll pump |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Model | BELPORE Series |
| Measurement Volume Range | 0.5–2 cm³ |
| Pressure Range | Vacuum to 414 MPa |
| Volume Measurement Accuracy | Better than 1% F.S. |
| Pressure Measurement Accuracy | Better than 0.1% F.S. |
| Maximum Data Points | 10,000 (intrusion) + 10,000 (extrusion) |
| Certified | CE, ISO 9001 |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP HP |
| Pressure Range | Up to 20 MPa (optional: 13.5 MPa) |
| Pressure Sensor Options | 1, 1.5, 2, 3.5, 13.5, or 20 MPa (±0.08% F.S.) |
| Temperature Control Range | 4.2 K – 673 K (via liquid He/N₂ cryostats, resistive furnaces, Peltier units, and air-bath thermal management) |
| Gas Inlets | 6 total (1 He for dead-volume calibration, 1 compressed air, 4 adsorptive gases) |
| Vacuum System | Optional turbomolecular pump + vacuum gauges |
| Compliance | Built-in compressibility factor (Z) and virial coefficient correction for non-ideal gas behavior |
| Sealing | Swagelok® filter-faced ferrules (0.5 µm pore size) |
| Thermal Stability | Air-bath manifold & reference chamber (15–35 °C, ±0.1 °C) |
| Software | BELSIM™ (isotherm modeling, PCT analysis), optional BELDyna™ (kinetic modeling: concentration vs. time, effective diffusivity, mass transfer coefficients) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELSORP MAX G |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Volumetric Gas Adsorption (Dynamic & Static Mode) |
| Number of Analysis Stations | 3 or 6 |
| Operating Temperature Range | 10–35 °C |
| Storage Temperature Range | 0–50 °C |
| Temperature Control Accuracy | ±1 °C |
| Vacuum System | Dual-stage rotary vane pump, ultimate vacuum ≤1 × 10⁻³ mmHg (≤0.13 Pa) |
| Pressure Sensors | 1 Torr, 10 Torr, and 1000 Torr high-precision capacitance manometers |
| Minimum Detectable Pressure Change | <1 × 10⁻⁵ Pa |
| Free Space Calibration | AFSM™ (Automatic Free Space Measurement) patented technology |
| Isotherm Range | P/P₀ = 1 × 10⁻⁷ to 0.997 at 77 K (N₂) and 87 K (Ar) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MINI X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption (Combined with Dynamic Pre-evacuation) |
| Analysis Stations | 4 |
| Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–133.3 kPa |
| Measurement Theory | Static Volumetric Method + Advanced Free Space Monitoring (AFSM™) |
| Compliance Options | FDA 21 CFR Part 11, IQ/OQ Documentation Package Available |
| Brand | Microtrac MRB |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 Series |
| Temperature Range | Ambient to 1100 °C (furnace), –100 °C (CryoCooker), up to 150 °C (gas lines) |
| Detection | High-Linearity TCD with corrosion-resistant filament |
| Gas Control | 12 independent gas inlets, 4 precision mass flow controllers |
| Analytical Modes | Pulse chemisorption, TPR, TPD, TPO, TPRx, vapor-phase adsorption |
| Vapor Capability | Integrated steam generator for pyridine, water, benzene, etc. |
| Cooling | KwikCool rapid furnace cooling system |
| Compliance | Designed for GLP/GMP environments |
| Brand | MITONG |
|---|---|
| Model | SYP-6538A |
| Type | Foam Trend Analyzer |
| Channels | 4 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Capacity | 27 L (Dual-Cylinder Design) |
| Gas Flow Rate | 300 mL/min (N₂) |
| Stirring Motor | 6 W, 1200 rpm |
| Foaming Tube | Borosilicate Glass with Graduations & Fritted Disc |
| Temperature Sensor | Pt100 Industrial Platinum Resistance Thermometer |
| Power Supply | AC 220 V ±10 %, 50 Hz ±5 % |
| Max. Power Consumption | ≤1800 W |
| Operating Environment | −10 °C to +35 °C, RH <85 % |
| Brand | Oxford Instruments |
|---|---|
| Origin | Switzerland |
| Model | FT-I04 |
| Instrument Type | Nanoindenter |
| Maximum Load Range | 2 N (across 5 selectable load channels) |
| Load Resolution | 0.5 nN (FT-S200 sensor) |
| Displacement Resolution | 0.05 pm |
| Indenter Tip Materials | Diamond, Tungsten Carbide, Sapphire |
| Indenter Geometries | Berkovich, Cube Corner, Flat Punch, Wedge, Conical, Spherical |
| Brand | Oxford Instruments |
|---|---|
| Origin | Switzerland |
| Model | FT-NMT04 |
| Load Range | 5 selectable full-scale channels, up to 2 N (FT-S2’000’000) |
| Load Resolution | 0.5 nN (FT-S200) |
| Displacement Range | 0.05 nm – 21 mm |
| Displacement Resolution | 0.05 pm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PICO-RHEED |
| Price | USD 220,000 (FOB Yokohama) |
| Brand | PMI Porometer / Porous Materials Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMP-60K-A-1 |
| Price | Upon Request |
| Pore Size Range | 3 nm – 500 µm (calculated per Washburn equation, dependent on mercury surface tension and contact angle) |
| Pressure Range | 0–60,000 psi (high-pressure station), 0–33,000 psi (dual-range configuration available) |
| Measurement Accuracy | Compliant with ASTM D4404 and ISO 15901-1 for mercury intrusion porosimetry |
| Sample Chamber Capacity | Standard 10 mL (customizable from 10–100 mL) |
| Number of Sample Stations | Single or dual chamber configuration |
| Intrusion Medium | High-purity mercury with isopropanol-assisted recovery system |
| Pressure Transducers | Triple-stage (low: 0–1000 Torr ≈ 20 psia |
| medium | 0–3000 psia |
| high | 0–60,000 psia) |
| Micrometered Dosing Tube Volume | Up to 2.1 cc (standard) |
| Brand | Porometer |
|---|---|
| Model | POROLIQ |
| Origin | Germany |
| Technology | Liquid-Liquid Displacement (LLP) |
| Measurement Principle | Capillary Flow Porometry via Immiscible Liquid Pair (e.g., Isopropanol/Water) |
| Minimum Detectable Pore Diameter | 2 nm |
| Data Acquisition Mode | Stepwise Pressure Ramp with Equilibrium Validation Algorithm |
| Compliance Framework | ASTM F316-22, ISO 15901-1, USP <801>, GLP/GMP-ready audit trail support |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX BP |
| Pressure Range | 0–5 bar (0–75 psi) |
| Pore Size Detection Range | 0.13–300 µm |
| Measurement Principle | Bubble Point Method (Capillary Flow Porometry) |
| Compliance | ASTM F316-22, ISO 4003, USP <801> |
| Software | POROLUX Control Suite v3.x (GLP-compliant audit trail, user access levels, 21 CFR Part 11 ready) |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | POROLUX Cito Series |
| Price Range | USD 14,000 – 140,000 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Flow Range | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Measurement Principle | Gas-Liquid Displacement Method (Capillary Flow Porometry) |
| Repeatability | ≤1% |
| Key | Brand: Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX Revo |
| Measurement Principle | Capillary Flow (Gas-Liquid Displacement) |
| Max Flow Rate | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Repeatability | ≤1% |
| Minimum Pore Size | 13 nm |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Brand | Porometer |
|---|---|
| Model | POROLUX™ Revo X |
| Origin | Germany |
| Measurement Principle | Gas-Liquid Capillary Flow (Capillary Flow Porometry, CFP) |
| Pore Size Range | 80 nm – 500 µm |
| Bubble Point Pressure Range | 0–8 bar (0–116 psi) |
| Max. Gas Flow Rate | 200 L/min |
| Dual Auto-Switching Flow Sensors | 0–10 L/min & 0–200 L/min |
| Dual Auto-Switching Pressure Sensors | 0–1 bar & 0–10 bar |
| Sample Holder Diameter | 25 mm |
| Max. Sample Thickness | 3 mm |
| Measurement Modes | Bubble Point (BP x-mL, BP pCF), Mean Flow Pore Size, Minimum Pore Size, Pore Size Distribution, Cumulative Flow Distribution, Gas Permeability |
| Optional Modules | Liquid Permeability, Fluid Source Integration |
| Software | PoreSmart™ with Curve Fitting, Statistical Pore Quantification (Total Pore Count, Total Pore Area [% & µm²], Open Porosity, Calculated Permeability in Darcy) |
| Patented Measurement Method | MP² (Multi-Step Pressure Progression) Technology |
| Compliance Ready | ASTM F316-22, ISO 15709:2022, USP <801>, GLP/GMP Data Integrity Support (Audit Trail, Electronic Signatures, 21 CFR Part 11 Ready) |
| Brand | POWEREACH |
|---|---|
| Model | JB04 |
| Origin | Shanghai, China |
| Light Source | 532 nm green laser (20 mW or 50 mW) |
| Laser Intensity Adjustment | 1–100% continuous |
| Objective Lens | Japanese MS-01 zoom objective, working distance 90 mm, magnification 700–1100 px/mm |
| Spatial Resolution | 2 µm |
| Incident Angle Range | 45°–60° |
| Polarization System | High-grade optical prism polarizer |
| Imaging Sensor | High-sensitivity CCD with electronic shutter |
| Image Acquisition | CG400 frame grabber card |
| Operating System Compatibility | Windows XP (32-bit), Windows 7 (32-bit) |
| Interface | RS232 serial port, native PCI slot required |
| Software | Proprietary GUI-based acquisition and analysis software |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JBT07 Series |
| Measurement Range | 10–100 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | Ambient (20–25°C typical) |
| Temperature Resolution | ±0.1°C |
| Bubble Frequency Range | 0.06–66 bubbles/s (water reference) |
| Bubble Lifetime Range | 0.015–1 s (water reference) |
| Detection Method | Maximum Bubble Pressure (MBP) |
| Power Supply | AC 220 V / 110 V, 50 Hz |
| Power Consumption | 50 W |
| Interface | RS-232 Serial (DB9) |