| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | FK31-SL |
| Temperature Range | −30 to +200 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | ±0.005 °C |
| Display | VFD + LCD backlight |
| Power Consumption | 2 kW |
| Dimensions (W × L × H) | 32 × 45 × 91 cm |
| Weight | 51 kg |
| Operating Ambient Temperature | 5–40 °C |
| Bath Opening | Ø12 cm × 31 cm depth |
| Fluid Capacity | 24 L |
| Refrigerant | R134a (GWP = 1430) |
| Pump Flow Rate | 22–26 L/min |
| Pump Pressure | 0.4–0.7 bar |
| External Pt100 Input | Integrated |
| Communication Interface | RS232 (optional Profibus) |
| Safety Compliance | DIN 12876-1 Class III (FL) |
| Control Technology | ICC + TCF + ATC3 |
| Programmable Ramp Profiles | 6 × 60 steps |
| Standard Bath Cover | 7-port stainless steel lid |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | SL-8K / SL-14K |
| Temperature Range | +50 to +300 °C |
| Temperature Stability | ±0.005 °C |
| Temperature Uniformity | < ±0.01 °C |
| Display | VFD & LCD |
| Heating Power | 3 kW |
| Pump Flow Rate | 22–26 L/min |
| Pump Pressure | 0.4–0.7 bar |
| Pump Suction | 0.2–0.4 bar |
| Bath Opening Diameter | 12 cm (SL-8K), 12 cm × 31 cm (SL-14K) |
| Liquid Capacity | 8 L (SL-8K), 14 L (SL-14K) |
| Dimensions (W×L×H) | 22×46×47 cm (SL-8K), 22×46×61 cm (SL-14K) |
| Weight | 16 kg (SL-8K), 20 kg (SL-14K) |
| Ambient Operating Temperature | 5–40 °C |
| Compliance | DIN 12876-1 Class III (FL), DIN ISO 9001:2000 |
| Communication Interface | RS232 (standard), optional RS485 / Profibus |
| External Pt100 Sensor Input | Integrated |
| Programmability | 6×60-step ramp/soak profiles |
| Safety Features | Overtemperature alarm, low-level alarm, dual-stage thermal cutoff |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | DROP D2HS |
| Temperature Range | -10 to 55°C |
| Temperature Accuracy | ±0.5°C |
| Resolution | 0.1°C |
| Operating Environment | -18°C to 60°C |
| Power Supply | User-replaceable CR2032 coin cell |
| Dimensions | 6 × 4.5 × 2.3 cm |
| Weight | 34 g |
| IP Rating | IP67 (30-min submersion) |
| Shock Resistance | MIL-STD-810G (1 m drop) |
| Data Capacity | >7,000 temperature/humidity records |
| Battery Life | Up to 4 months (typical use) |
| Wireless Range | Up to 30 m (100 ft) via Bluetooth® 4.0+ |
| Computation Capabilities | Heat Stress Index (HSI), Dew Point Temperature |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EL-USB-2-LCD |
| Pricing | Available Upon Request |
| Temperature Range | −35 °C to +80 °C |
| Humidity Range | 0–100 %RH |
| Temperature Accuracy | ±0.5 °C |
| Humidity Accuracy | ±3 %RH (20–80 %RH), ±5 %RH (outside) |
| Memory Capacity | 16,379 readings |
| Battery Life | Up to 1 year (typical at 25 °C, 2-min logging interval) |
| Display | Integrated LCD (shows real-time temp/RH, min/max, status) |
| Interface | USB-A plug-and-play for data download and configuration |
| Logging Interval | Configurable from 1 second to 12 hours |
| Operating Environment | Indoor, non-condensing environments |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 |
| Temperature Range | –196 °C to +125 °C (with LN₂ cooling pump) |
| Heating Rate | Up to 150 °C/min |
| Temperature Stability | < 0.1 °C |
| Sensor | 100 Ω Platinum RTD |
| Vacuum Level | Down to 10⁻³ mbar |
| Sample Area | Ø22 mm |
| XY Manipulation Range | 15 mm |
| Window Thickness | 0.5 mm (single ultra-thin optical window) |
| Sample Volume | As low as 5 µL |
| Compatible With | Polarized light, phase contrast, confocal microscopy, Raman spectroscopy, FTIR, and X-ray imaging |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | INE700 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mini-InfraPro4 |
| Price | Upon Request |
| Temperature Range (Mini-InfraPro4) | –18 °C to 400 °C |
| Temperature Range (Mini-InfraPro6) | –30 °C to 500 °C |
| Resolution | 0.1 °C/°F |
| Accuracy | ±3 °C (–18 to –1 °C), ±1 °C (10 to 30 °C), ±2% or ±2 °C (whichever is greater) for –1 to 400 °C |
| Response Time | 500 ms (95% response) |
| Emissivity | Fixed at 0.95 |
| Laser Targeting | Single-point, Class II |
| Distance-to-Spot Ratio | 8:1 (Mini-InfraPro4), 10:1 (Mini-InfraPro6) |
| Dimensions (L × W × H) | 10.2 × 15.2 × 4.0 cm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 91426-50 |
| Pricing | Available Upon Request |
| Sensor Type | High-Accuracy Thermistor Probe |
| Temperature Range | –40 °C to +150 °C |
| Accuracy | ±0.03 °C (–40 to 99.99 °C), ±0.1 °C (100 to 125 °C), ±0.5 °C (125 to 150 °C) |
| Resolution | 0.01 °C (–40 to 99.99 °C), 0.1 °C (100 to 150 °C) |
| Display | Backlit LED, Dual-Unit (°C/°F), Min/Max/Hold |
| Data Logging | 2000-point internal memory |
| Interface | USB 2.0 |
| Sampling Interval | 1 s to 60 min |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 10.2 × 17.8 × 5.1 cm |
| Power | 4 × AA batteries (included), Auto-off, Low-battery indicator |
| Calibration | Internal auto-calibration routine |
| Standard Accessories | Protective carrying case (probe not included) |
| Brand | PST |
|---|---|
| Origin | Switzerland |
| Model Range | HF1 / HF3, CRP5 Series, HF5 / HF5-EX |
| Output Options | Analog (4–20 mA / 0–10 V) and Digital (RS485 Modbus RTU, optional BACnet MS/TP) |
| Enclosure Rating | IP65 (standard), IP67 (HF5-EX variant) |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity Range | 0–100 %RH |
| Accuracy | ±0.8 %RH (typ. at 23 °C, 30–70 %RH), ±0.15 °C (typ. at 23 °C) |
| Probe Configuration | Interchangeable or Fixed Integrated Sensing Elements |
| Certifications | CE, RoHS, ATEX II 2G Ex db IIB T4 Gb (HF5-EX), UL Listed (pending for HF5 series) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WT |
| Pricing | Available Upon Request |
| Probe Material | Stainless Steel |
| Probe Length | 30 cm |
| Temperature Range | −6 °C to 41 °C |
| Accuracy | ±0.2 °C |
| Response Time (in water) | 5–8 min to thermal equilibrium |
| Maximum Readout Delay Post-Extraction | 20 s |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41382LC2 |
| Temperature Range | -50 to +50 °C |
| Temperature Accuracy | ±0.3 °C (@ 23 °C) |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±1 %RH (@ 20 °C) |
| RH Stability | <1 %RH/year |
| RH Response Time | 10 s (unshielded) |
| Temperature Response Time | 10 s (unshielded) |
| Output Signal | 4–20 mA (2-wire loop-powered) |
| Supply Voltage | 12–30 VDC |
| Max Current Draw | 46 mA |
| Sensor Type | Pt100 RTD (temperature), Rotronic Hygromer® (humidity) |
| Enclosure Dimensions | Ø64 mm × 176 mm |
| Weight | 200 g |
| Recommended Cable | 2-pair shielded, 22 AWG |
| Optional Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41382VC |
| Temperature Range | -50 to +50 °C |
| Temperature Accuracy | ±0.3 °C @ 23 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±1 %RH @ 20 °C |
| RH Stability | <1 %RH/year |
| Response Time (with radiation shield) | 10 s |
| Output Signal | 0–1 VDC or 0–5 VDC (jumper-selectable) |
| Power Supply | 12–30 VDC |
| Operating Ambient Temperature | -50 to +50 °C |
| Dimensions | Ø64 mm × 176 mm |
| Weight | 200 g |
| Sensor Type (Temp) | Platinum RTD (Pt1000) |
| Sensor Type (RH) | Rotronic Hygromer® capacitive polymer |
| Recommended Cable | 5-conductor shielded (Young P/N 18723) |
| Optional Radiation Shields | 43502 (aspirated), 41003P (multi-layer passive) |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | ASTM Series / IP Series |
| Temperature Range | ASTM: 1 °C to 137 °C |
| IP | 1 °C to 102 °C |
| Compliance | ASTM D129, D86, D95, D126, D4294 |
| Construction | Fully Immersed, Total-Immersion Mercury-in-Glass or Precision Alcohol-Filled Capillary Thermometers |
| Calibration | Individually Certified to NIST-Traceable Standards |
| Accuracy | ±0.1 °C (typical for Class A reference thermometers per ASTM E77 and ISO 17025) |
| Graduation | Fine-etched Scale with 0.1 °C or 0.2 °C Minor Divisions |
| Stem Design | Standard or Partial Immersion, Depending on ASTM/IP Specification Requirement |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 800024 |
| Price | Upon Request |
| Channels | 4 independent inputs |
| Sensor Type | K-type thermocouples |
| Temperature Range | −200 °C to +1370 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.2% of reading + 1 °C (−200 to 200 °C), ±0.5% of reading + 1 °C (200 to 400 °C), ±0.2% of reading + 1 °C (400 to 1370 °C) |
| Data Logging Capacity | 16,000 readings |
| Interface | RS232 serial port |
| Power Supply | 9 V alkaline battery or optional AC adapter |
| Dimensions (L×W×H) | 18.5 × 6.4 × 3.2 cm |
| Standard Accessories | Two K-type thermocouple probes, RS232 cable, data logging software |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A.B.C.D.E Temperature Indicating Strip |
| Pricing | Available Upon Request |
| Temperature Range | −30 °C to 260 °C |
| Accuracy | ±1 °C |
| Calibration Traceability | ISO/IEC 17025-accredited reference standards |
| Compliance | ISO 9001 certified manufacturing & quality control |
| Format | Adhesive-backed multi-point irreversible thermal indicator strip with 5 discrete temperature bands (A–E), each containing 8 calibrated temperature-sensitive elements |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TES-PAPER |
| Pricing | Available Upon Request |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| IP Rating | IP65 |
| Probe Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Folded Dimensions | 163 × 47 × 20 mm |
| Extended Dimensions | 265 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Power Supply | 2 × AAA batteries |
| Battery Life | 100 h (+25 °C, no backlight) |
| Display | Single-line LCD with backlight |
| Compliance | EN 13485, HACCP, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1063 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-30 to +99.9 °C), ±1.0 °C (full range) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| Power Source | CR2032 lithium coin cell |
| Dimensions (L×W×H) | 215 × 34 × 19 mm |
| Weight | 80 g |
| IP Rating | IP67 (with protective sleeve 0516 8265) |
| Measurement Rate | 2 readings per second |
| Compliance | ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | −10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery (approx. 70 h lifetime) |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Sensor Type | Integrated capacitive humidity sensor + NTC temperature sensor |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| IP Rating | IP65 |
| Dimensions (probe extended) | 265 × 47 × 20 mm |
| Dimensions (probe folded) | 163 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Probe Shaft Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| Display | Single-line LCD with backlight |
| Power | 2 × AAA batteries (100 h life at +25 °C, no backlight) |
| Compliance | EN 13485, HACCP principles, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1052 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-20 to +100 °C), ±1.0 °C (-50 to -20.1 °C), ±1% of reading (+100.1 to +275 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| IP Rating | IP65 |
| Display | Backlit LCD (single-line) |
| Power Supply | LR44 button cell battery (80 h typical life) |
| Dimensions (with standard probe) | 148 × 38 × 195 mm |
| Weight (instrument only, standard probe) | 156 g |
| Response Time t₉₉ | 10 s (standard/long probe in liquid), 15 s (frozen goods probe in frozen meat ≈ 60 s) |
| Compliance | EN 13485, HACCP principles, FDA food safety guidelines |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model No. | 0563 1063 |
| Price Range | USD 0.15–750 (FOB) |
| Instrument Category | Insertion-Type Food Thermometer |
| Temperature Range | −50 °C to +275 °C |
| Accuracy | ±0.5 °C (within −20 °C to +50 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | −20 °C to +50 °C |
| Display | Integrated LCD (backlit) |
| Power Supply | 1 × CR2032 button cell (included) |
| Dimensions (L×W×H) | 215 mm × 34 mm × 19 mm |
| Weight | 80 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 6053 |
| Temperature Range | 0 to +50 °C |
| Temperature Accuracy | ±0.5 °C |
| Relative Humidity Resolution | 0.1 %RH |
| Operating Ambient Temperature | 0 to +50 °C |
| Display | Rotatable LCD screen |
| Power Supply | 3 × AAA batteries |
| Dimensions | 12 mm (thickness) |
| Weight | 75 g (including batteries, excluding packaging) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | -10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | -20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Enclosure Material | ABS |
| Battery Life | ~70 h |
| Storage Temperature | -40 to +70 °C |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 625 |
| Price Range | USD 1–4,999 |
| Instrument Type | General-Purpose Temperature & Humidity Meter |
| Temperature Range | −10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Operating Ambient Temperature | −20 to +50 °C |
| Display | Digital LCD |
| Power Supply | 9 V battery |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Storage Temperature | −40 to +70 °C |
| Battery Life | ~70 h |
| Housing Material | ABS |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0646 0073 |
| Temperature Range | +116 to +138 °C |
| Accuracy | ±1.5 °C |
| Operating Ambient Temperature | +116 to +138 °C |
| Dimensions | 15 mm diameter |
| Weight | 1 g |
| Quantity per Pad | 10 units |
| Indication Points | +116, +122, +128, +132, +138 °C (customizable thresholds per variant) |
| Response Time | ≤3 seconds upon exceeding threshold |
| Irreversible Visual Indication | Yes |
| Compliance | CE-marked, RoHS-compliant, designed for industrial process monitoring and cold chain validation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp JKT |
| Price | Upon Request |
| Thermocouple Types | J, K, T |
| Temperature Range | –250 °C to 1372 °C (K-type), –250 °C to 400 °C (T-type), –2.00 °C to 1000 °C (J-type) |
| Resolution | 0.1 °C (–99.9 °C to 299.9 °C) |
| Accuracy | ±0.2% of reading + 0.5 °C (t > –99.9 °C) |
| Offset Adjustment | ±10 °C |
| Display | LCD |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Operating Temperature | –10 °C to 50 °C |
| Dimensions (unit) | 140 × 70 × 35 mm |
| Weight (unit) | 200 g |
| Input Connector | 2-pin ANSI mini thermocouple interface |
| Data Hold | Yes |
| Auto Power-Off | Yes |
| Low-Battery Indicator | Yes |
| Factory-Calibrated | Yes |
| Self-Diagnostic Functions | Yes |
| Key-Based Calibration | Yes |
| Power-Save Mode | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | Temp 10 |
| Pricing | Upon Request |
| Temperature Ranges | J-type: −210 to 1200 °C (−346 to 2192 °F), K-type: −250 to 1372 °C (−418 to 2501 °F), T-type: −250 to 400 °C (−418 to 725 °F) |
| Resolution | 0.1 °C/°F below 1000 °C/°F |
| Accuracy | ±0.25% of reading ±1 °C below −150 °C |
| Display | 58 × 40 mm backlit LCD, dual-line |
| Min/Max Hold | Yes |
| Auto Power-Off | 17.5 min (configurable) |
| Data Hold & Stability Indicator | Yes |
| Input | Single thermocouple channel |
| Power | 3 × AA 1.5 V alkaline batteries |
| Operating Environment | −40 to 65 °C, 10–90% RH (non-condensing) |
| Dimensions (bare) | 175 × 97 × 42 mm |
| Weight (bare) | 267 g |
| Dimensions (with protective case) | 180 × 102 × 52 mm |
| Weight (with case) | 362 g |
| Ingress Protection | IP54 per IEC 60529 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Temp 14 |
| Price | Upon Request |
| Measurement Range | -40 to 150 °C (-40.0 to 302.0 °F) |
| Resolution | 0.1 °C / 0.1 °F |
| Accuracy | ±0.2 °C (±0.4 °F) from -40 to 125 °C |
| Display | Backlit LCD, 58 × 40 mm |
| Min/Max Hold | Yes |
| Auto Power-Off | 17.5 min (configurable) |
| Data Hold & Stability Indicator | Yes |
| Input | Single-channel, 6.3 mm phone jack |
| Power | 3 × AA 1.5 V alkaline batteries (>750 h without backlight) |
| Operating Environment | -40 to 65 °C, 10–90 % RH (non-condensing) |
| Dimensions (without case) | 175 × 97 × 42 mm |
| Weight (without case) | 267 g |
| Dimensions (with case) | 180 × 102 × 52 mm |
| Weight (with case) | 362 g |
| Ingress Protection | IP54 per IEC 60529 |
| EMC Compliance | EN 61326-1/A1:1998 (EU EMC Directive) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Temp 16 |
| Price | Upon Request |
| Measurement Range | −200.0 to +850.0 °C (−392.0 to +1562.0 °F) |
| Resolution | 0.1 °C / 0.1 °F (−200.0–999.9), 1 °F (1000–1562) |
| Accuracy | ±2.0 °C (−200.0 to −100.0 °C), ±0.2 °C (−99.9 to +199.9 °C), ±2.0 °C (+200.0 to +850.0 °C) |
| Display | 58 × 40 mm backlit LCD, dual-line |
| Min/Max Hold | Yes |
| Auto Power-Off | 17.5 min (configurable) |
| Data Hold & Stability Indicator | Yes |
| Input | Single-channel 3-pin TA3F connector |
| Power | 3 × AA 1.5 V alkaline batteries (>750 h without backlight) |
| Operating Environment | −20 to +50 °C, 10–90 % RH (non-condensing) |
| Storage | −40 to +65 °C, 10–90 % RH |
| Dimensions (w/o case) | 175 × 97 × 42 mm |
| Weight (w/o case) | 267 g |
| Enclosure Rating | IP54 |
| Compliance | CE (EN 61326-1/A1:1998), IEC 529 |