Thermal Analysis Instruments
Filter
Showing 1–30 of 244 results
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QT-36 |
| Pricing | Available Upon Request |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QT-36 |
| Pricing | Available Upon Request |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | M5000 |
| Temperature Range | 25–400 °C |
| Heating Rate | 1 °C/min |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Diameter | 1.4 mm |
| Sample Capacity | 1 capillary per measurement |
| Temperature Resolution | 0.1 °C |
| Cooling | Integrated fan-assisted cooling |
| Safety Rating | IP20 |
| Dimensions (L×W×H) | 230 × 210 × 110 mm |
| Weight | 1.8 kg |
| Power Supply | 85–264 V AC, 47–440 Hz |
| Interface | RS-232 |
| Brand | AcroEdge |
|---|---|
| Origin | Imported (Non-Chinese) |
| Model | AV-10 |
| Measurement Principle | Rotational (Couette flow geometry) |
| Torque Sensing | High-resolution electromagnetic torque transducer |
| Speed Control | Closed-loop DC motor with optical encoder feedback |
| Output Interfaces | RS-485, USB 2.0, Ethernet (TCP/IP), 4–20 mA analog output |
| Alarm Outputs | Dual programmable digital relay (Hi/Lo) |
| Temperature Compensation | Built-in RTD input (PT100 compatible) |
| Enclosure Rating | IP65 (sensor head), IP54 (controller unit) |
| Power Supply | 24 VDC ±10% |
| Operating Temperature | −10 to +60 °C (electronics), −20 to +150 °C (wetted sensor parts) |
| Wetted Materials | 316L stainless steel, Hastelloy C-276 optional |
| Air/N₂ Purge Port | Integrated on probe housing |
| Configuration | Modular — separate sensing probe and remote control unit |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | Curea |
| Excitation Wavelength | 365 nm |
| Spot Diameter | 2 mm |
| Working Distance | 43 mm |
| Measurement Time | 0.1 s |
| Dimensions (W×D×H) | 50×75×125 mm |
| Weight | ~900 g |
| Application | Real-time non-contact UV-curable resin cure monitoring |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | EU201 |
| Measurement Principle | Laser Displacement + Load Cell-Based Stress Monitoring |
| Temperature Control Range | –50 °C to 300 °C (programmable ramp/soak) |
| Laser Source | 655 nm Class 1 semiconductor diode (220 µW) |
| Displacement Resolution | 2 µm |
| Force Sensing Range | 5 N (standard), optional ranges: 500 mN, 1 N, 2 N, 10 N, 20 N |
| Force Nonlinearity | ±0.5 % RO |
| Force Repeatability | ±0.5 % RO |
| Heating Power | 450 W (3×50 W elements) |
| Cooling Unit Capacity | 450 W (10–25 °C adjustable) |
| Sample Volume | ~1 mL |
| Compliance | ISO 4216:2021, JIS K6941:2019 |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | F-CAL |
| Measurement Principle | Heat Flow Method |
| Thermal Resistance Range | 1×10⁻⁵ m²·K/W |
| Repeatability | <2% fluctuation |
| Test Atmosphere | Ambient air |
| Hot-Side Temperature Setting | 50°C |
| Sample Geometry | Square, 25 mm or 40 mm edge length, thickness 1–5 mm |
| Instrument Type | Steady-State Thermal Resistance Analyzer |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | HT-RTA59HD |
| Heating Method | High-Power Focused Halogen Lamp |
| Max Temperature | 1800 °C (achieved in ≤10 s for □15 mm samples) |
| Sample Chamber Atmosphere | Dual-gas inlet (N₂ and Ar), quartz tube encapsulation |
| Cooling | Forced-air cooling for lamp assembly |
| Form Factor | Benchtop, manual slide-rail sample loading |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Advance Riko |
| Pricing | Available Upon Request |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model Series | PS, PSS |
| Heating Zone Width (PS) | 40 mm |
| Heating Zone Width (PSS) | 20 mm |
| Compatible Substrate Diameter | 50–300 mm |
| Application Scope | Rapid thermal processing (RTP), wafer annealing, solar cell sintering, FPD substrate heating, thin-metal foil annealing |
| Configuration | Modular assembly for extended heating zones |
| Compliance | Designed for integration into Class 100–1000 cleanroom-compatible production lines |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | RHL-E Series |
| Heating Principle | Radiative heating via high-intensity near-infrared lamp array with water-cooled gold-coated elliptical reflector |
| Max Operating Temperature (E-type) | Up to 1200°C |
| Lamp Spectral Peak | ~1.15 µm |
| Reflector Material | Precision-polished aluminum substrate with vacuum-deposited Au coating |
| Cooling | Integrated water-circulation jacket for reflector and chamber housing |
| Sample Geometry Compatibility | Cylindrical/rod-shaped specimens |
| Reflective Geometry | Elliptical (E-series) |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super LIX-R |
| Price | Upon Request |
| Temperature Range (°C) | 0–50 |
| Heating/Cooling Rate (°C/min) | 0.01–1.5 |
| Temperature Accuracy (°C) | ±0.1 |
| Sample Diameter (mm) | Φ5 ±0.5 |
| Sample Length (mm) | 12–20 |
| Measurement Range (µm) | 20 |
| Resolution (nm) | <0.2 |
| CTE Detection Limit | 5 × 10⁻⁹ K⁻¹ |
| Thermal Stability | <±0.001 °C/min at 0.1 °C/min ramp |
| Atmosphere | Low-pressure He (100 Pa) |
| Sensor | PT-100 Platinum RTD (JIS C 1604-1997 Class A) |
| Laser | He-Ne, 632.8 nm, 5 mW (IEC 60825-1 Class 3B) |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | TC-1200RH |
| Measurement Principle | Laser Flash Method (LFM) |
| Temperature Range | RT to 1150 °C (up to 1200 °C short-term) |
| Thermal Conductivity Range | 0.1–2000 W/m·K |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Sample Dimensions | Ø10 mm × 1–3 mm (thickness), measured through-thickness |
| Atmosphere | Vacuum (standard) |
| Heating Rate | 10 °C/min (to 100 °C), 20 °C/min (to 300 °C), 50 °C/min (to 1150 °C) |
| Dimensions (W×D×H) | 900 × 1050 × 1700 mm |
| Weight | ~350 kg |
| Power Supply | AC200 V, single-phase, 8 kVA (main unit) |
| Cooling Water | ≥5 L/min, pressure ≥0.15 MPa |
| Compliance | JIS R 1611, JIS R 1650-3, JIS H 7801, ISO 13826, ASTM E1461 |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | TCN-2ω |
| Measurement Principle | 2ω Lock-in Thermography (Frequency-Domain Modulated Joule Heating) |
| Test Temperature | Ambient (23 ± 2 °C) |
| Sample Dimensions | 10–20 mm (L) × 10 mm (W) × 0.3–1 mm (total thickness, including substrate) |
| Substrate Materials | Si (recommended), Ge, Al₂O₃ |
| Metal Transducer Film | Au (100 nm, 1.7 mm × 15 mm) |
| Thermal Conductivity Range | 0.1–10 W·m⁻¹·K⁻¹ |
| Atmosphere | Ambient air |
| Compliance | ISO/IEC 17025-aligned methodology, compatible with GLP documentation workflows |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | TCA-3030 |
| Measurement Principle | Guarded Hot Plate Method (ASTM C177 / ISO 8302 / GB/T 10294-2008) |
| Thermal Conductivity Range | 0.01–1 W/(m·K) |
| Accuracy | ≤1% |
| Repeatability | ≤1% |
| Temperature Range (Cold Plate) | 5–90 °C |
| Max. Hot Plate Temperature | 120 °C |
| Sample Dimensions | 300 mm × 300 mm, Thickness ≤37.5 mm |
| Sample Form | Solid, Homogeneous Flat Panels |
| Test Environment | Ambient (Controlled Room: 8–35 °C, RH <80%) |
| Power Supply | 3 kW, 220 V AC |
| Overall Dimensions (L×W×H) | 1120 × 830 × 1600 mm |
| Automation | Microprocessor-Controlled with Real-Time Data Acquisition & Reporting |
| Compliance | Fully aligned with GB/T 10294-2008, ASTM C177, ISO 8302, and EN 12664 for steady-state thermal resistance measurement |
| Brand | Aiyao Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PCA |
| Pricing | Available Upon Request |
| Brand | Aiyao Instruments |
|---|---|
| Model | TCT |
| Measurement Principle | 3ω Method |
| Sample Form | Micro/Nano Thin Films (Supported & Freestanding) |
| Temperature Range | Ambient to 400 °C (Optional Cryogenic Extension Available) |
| Thermal Conductivity Range | 0.1–1000 W/(m·K) |
| Resolution | <0.5% of Full Scale |
| Data Acquisition | High-Precision Digital Source Meter + Dual-Phase Lock-in Amplifier |
| Compliance | ASTM E1461, ISO 22007-2 (Adapted), GLP-Compatible Audit Trail Logging |
| Brand | Aiyao Instruments |
|---|---|
| Model | TEA |
| Measurement Principle | Optical Interferometry |
| Sample Type | Transparent Bulk & Thin-Film Materials |
| Heating Method | IR Heater with PID + Fuzzy Logic Control |
| Temperature Control Mode | Programmable Ramp & Isothermal Hold |
| Vacuum Port | Yes |
| Cooling Interface | Water-Cooled Heat Exchanger & Optional Cryogenic/Gas Purge Connection |
| Origin | Hubei, China |
| Distributor Type | Authorized Domestic Distributor |
| Compliance | Designed for ISO 11359-2 and ASTM E228 Conformance Context |
| Brand | Akrometrix |
|---|---|
| Origin | USA |
| Model | Customized |
| Sample Size Range | 0.5 mm × 0.5 mm to 400 mm × 400 mm |
| Warpage Resolution | <1 µm |
| Data Acquisition Density | 1.4 million points per 2 seconds |
| Temperature Control | IR heating + convection cooling |
| Temp Range | −50 °C to 300 °C |
| Reflow Simulation Support | up to 300 °C |
| Brand | AKTS |
|---|---|
| Origin | Switzerland |
| Model | CALISTO Thermal Kinetics Software |
| Software Modules | CALISTO Acquisition (instrument control for SETARAM systems) & CALISTO Processing (vendor-agnostic data analysis) |
| Compliance | Designed for GLP/GMP environments with audit trail readiness |
| Data Handling | Supports DSC, TGA, and calorimetry datasets from multiple manufacturers |
| Key Mathematical Capabilities | Heat capacity determination, peak deconvolution, inverse filtering, glass transition analysis, decay modeling, custom equation fitting, advanced baseline construction, solid/liquid ratio calculation, reaction kinetics profiling, baseline subtraction, normalization, numerical integration, TMA alpha-point extraction (true α, mean α), temperature calibration correction, mass loss quantification, tare compensation, derivative computation (with configurable filter types), Gaussian & Savitzky–Golay filtering, curve segmentation, slope correction, natural logarithm transformation, inflection point detection, spike removal |
| Output Formats | Native .cali project files, export to PDF, PNG, SVG, CSV, and Word-compatible vector graphics (auto-resized for optimal print/display resolution) |
| Brand | AKTS |
|---|---|
| Origin | Switzerland |
| Model | ThermoKinetics Software Suite |
| Application | Kinetic Analysis of Thermal Data (DSC, DTA, TGA, TG-MS, TG-FTIR) |
| Compliance | ASTM E698, ISO 11358, USP <1031>, ICH Q5C, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Deployment | Windows-based standalone application with optional network license server support |
| Data Import | Native support for NETZSCH, TA Instruments, SETARAM, PerkinElmer, Mettler Toledo, Hitachi thermal analyzers |
| [Brand | Alpha |
|---|---|
| Origin | USA |
| Model | AR008 |
| Type | High-Purity Combustion Flux for Inert Gas Fusion Analyzers |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/CS Instruments |
| Form | Granular |
| Purity | ≥99.95% (certified) |
| Packaging | Sealed 100 g or 500 g HDPE bottles under argon atmosphere |
| Storage | Dry, cool, inert environment |
| Safety | Non-hygroscopic, low volatility, compliant with OSHA and GHS handling guidelines] |
| [Brand | Alpha / ALPHA |
|---|---|
| Origin | USA |
| Model | AR3818F |
| Type | Low-carbon graphite crucible |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/O/N/H analyzers |
| Purity | <5 ppm C (typical), <10 ppm S (typical) |
| Dimensions | Ø25 mm × 35 mm (ID × height, nominal) |
| Max. Operating Temperature | 3,000 °C in inert atmosphere |
| Packaging | 10 pcs per sealed vacuum bag, 100 pcs per box] |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | AR5431P |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH analyzers |
| Packaging | 100 pcs per box |
| OEM Cross-Reference | ELTRA® 775-431, LECO® 775-431, HORIBA® 775-431, Bruker® 775-431 |
| Brand | Alpha Resources |
|---|---|
| Origin | USA |
| Model | AR433 |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH-p/D Series |
| Packaging | 50 pcs per box |
| OEM Cross-Reference | 90185775-433 |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | CTE-360 |
| Temperature Range | –25 °C to +100 °C |
| Compliance | ASTM D696, ASTM E228 |
| Sample Max Cross-Section | 12.5 mm (0.5 in) |
| Recommended Sample Length | 50 mm (2 in) |
| CTE Accuracy | ±3% (full 100 °C range) |
| Power Supply | 100–230 VAC, 50/60 Hz, ≤400 W |
| Dimensions | 43 × 43 × 43 cm (17 × 17 × 17 in) |
| Weight | 9 kg (20 lb) |
| Software | WinCTE v1.x (Windows 7–11, 32/64-bit) |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | Phase12 |
| Heating Current Options | 2 A / 10 A / 20 A / 100 A (Phase12B) |
| Sampling Rate | 1 MHz |
| Temperature Resolution | ±0.007°C (Tj digital), ±0.1°C (display), ±0.2–0.5°C (absolute) |
| Thermocouple Accuracy | ±0.15°C (typ.), ±0.3°C (max.) |
| Heating Voltage Accuracy | ±0.2% rdg + 0.025% FS (50 V) for Phase12 |
| Transient Time Resolution | 1 µs |
| Transient Span | 1 µs – 1000 s |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | PHASE12 |
| Compliance | JEDEC JESD51-1, JESD51-14, JESD51-8, JESD51-12 |
| Thermal Resolution | ±0.007°C |
| Junction Temperature Accuracy | ±0.1°C |
| Voltage Measurement Accuracy | ±0.25% (0–30 V) |
| Current Measurement Accuracy | ±0.25% |
| Sampling Rate | 1 MHz |
| Max Standard Current Output | 18 A |
| Optional High-Current Power Booster | up to 1000 A |
| Junction Sensing Current Options | 1–50 mA |
| Calibration Temperature Range | Ambient to 180°C |
| Input Power | 220 VAC, 5 A, 50/60 Hz |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | TIM1300 / TIM1400 |
| Test Method | ASTM D5470 |
| Sample Diameter | 1.3 in (33 mm) |
| Thickness Range | 0–20 mm |
| Temperature Range | 20–65°C (TIM1300), 20–130°C (TIM1400) |
| Contact Pressure Range | 5–380 psi (34–2600 kPa) |
| Thickness Measurement Accuracy | ±1% + 0.001 in (±25 µm) |
| Thermal Resistance Range | 0.005–8 K/W |
| Power Supply | 100–230 VAC, 50/60 Hz |
| Cooling Requirement | 6 L/min @ 10–35°C, ±0.1°C stability |
| Compressed Air | ≥90 psi (600 kPa), 10 µm filtration |
| Dimensions (H×W×D) | 58×41×43 cm |
| Weight | 19 kg (TIM1300), 21 kg (TIM1400) |
| Brand | ANALYSIS TECH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | TIMTester 1300, TIMTester 1400 |
| Pricing | Upon Request |