Thermal Analysis Instruments
Filter
Showing 91–120 of 922 results
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRH300 |
| Quotation | USD 7,650 (FOB) |
| Instrument Type | Guarded Hot Plate Method |
| Dimensions (L×W×H) | 1200 × 700 × 1300 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–3.0 W/(m·K) |
| Repeatability | 1% |
| Temperature Control Range (DRH300A/B/C variants) | 0–40 °C / RT–100 °C / −20–70 °C |
| Sample Size Max | 300 × 300 × 100 mm |
| Thermal Resistance Range | 0.1–8.0 m²·K/W |
| Control System | Peltier-based heated/cooled plates with dual embedded heat flux sensors |
| Compliance | ASTM C518, ISO 8301, GB/T 10294, GB/T 10295, JIS A 1412, DIN EN 12939, DIN EN 13163, DIN EN 12667 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DRK-R70 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Accuracy | ±0.3 °C (<250 °C) |
| Capillary Dimensions | Outer Diameter 1.3 mm, Inner Diameter 1.1 mm |
| Temperature Resolution | 0.01 °C |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DRX-I-JH |
| Pricing | Available Upon Request |
| Max Operating Temperature | RT–600°C / RT–1000°C (configurable) |
| Thermal Conductivity Range | 0.035–40 W/(m·K) and 20–500 W/(m·K) (material-dependent) |
| Sample Geometry | Cylindrical rods (Ø5 × 220 mm for metals |
| Wire Samples | Ø1–3 mm diameter |
| Sample Quantity | ≥2 per test run |
| Measurement Accuracy | ≤5% (typical), down to ±2% under optimized calibration and controlled conditions |
| Vacuum/Atmosphere Control | Customizable (high-vacuum or inert gas purge options) |
| Automation | Fully computer-controlled heating ramping, data acquisition, real-time calculation, and report generation |
| Power Supply | 220 V AC, ≤4 kW total consumption |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DRX-I-RX |
| Price Range | USD 1,400–7,200 (FOB) |
| Instrument Type | Transient Hot Wire Method (THW) |
| Dimensions (L×W×H) | 110 × 150 × 65 cm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.015–20 W/(m·K) |
| Repeatability | ±2% |
| Max Test Temperature | 1000 °C / 1400 °C / 1600 °C (configurable) |
| Sample Size Limit | 230 × 114 × 65 mm |
| Heating Power Control | Programmable & Computer-Regulated |
| Dual-Mode Capability | Cross-Wire & Parallel-Wire THW |
| Software Platform | Windows 7/XP-based thermal analysis application with automated data acquisition and report generation |
| Optional Modules | Specific Heat Capacity Measurement Module (accuracy: ±7–10%), Transient Line Source (TLS), and Needle Probe Method Adapters |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-LUX |
| Price | Upon Request |
| Measurement Principle | Steady-State Guarded Hot Plate (Modified ASTM C177 / ISO 8302 compliant architecture) |
| Heat Plate Diameter | Φ65 mm |
| Heat Plate Temp | 60 ± 0.1 °C (Pt100 controlled) |
| Cold Plate Temp | 20 ± 0.1 °C (water-cooled, Pt100 controlled) |
| Preheater Temp | 40 °C (optional) |
| Coolant Temp Control | 20 ± 0.5 °C |
| Coolant Flow Rate | 40 L/h |
| Temperature Differential Resolution | ±0.1 °C (via differential thermopile or dual Pt100) |
| Sample Dimension | Φ50 × 50 mm |
| Thickness Measurement Accuracy | ±0.01 mm (digital caliper) |
| Test Duration | 5–20 min |
| Contact Pressure | Manual or motorized preloading system |
| Max Power Consumption | ≤1.5 kW |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-RL |
| Pricing | Available Upon Request |
| Temperature Range Options | −196 °C to RT, −30 °C to 90 °C, −20 °C to 70 °C, 0 °C to 40 °C, 0 °C to 100 °C |
| Temperature Resolution | 0.01 °C |
| Sample Diameter | Φ10–30 mm |
| Sample Thickness | 0.02–50 mm |
| Thermal Resistance Range | 0.1–8.0 m²·K/W |
| Thermal Conductivity Range | 0.015–100 W/(m·K) and 0.015–40 W/(m·K) |
| Accuracy | ≤±3% (thermal conductivity), ±5% (thermal diffusivity), ±7% (specific heat) |
| Repeatability | 0.3–0.5% |
| Cooling Options | Forced-air, External Water Bath, Liquid Nitrogen |
| Control | Motorized Plate Actuation, Programmable Temperature Ramp (1–10 setpoints), Embedded Controller + PC Interface |
| Compliance Standards | ASTM D5470-06, ASTM E1530, ASTM C518, ISO 8301, JIS A1412, DIN EN 12939, DIN EN 13163, DIN EN 12667, MIL-I-49456A |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic |
| Model | DRX-II-RW |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Heat Flow Method |
| Dimensions (L×W×H) | 550 × 450 × 780 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.5–100 W/(m·K) |
| Repeatability | ≤±1% |
| Specific Heat Measurement Accuracy | ±7% |
| Thermal Diffusivity Measurement Accuracy | ±5% |
| Operating Temperature Range | 20–300 °C |
| Sample Diameter | 15–50 mm |
| Sample Thickness | 1–50 mm |
| Compliance Standards | GB 5598–1985, GB 11205–1989, MIL-I-49456A, ASTM D5470–06 |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DDV-II |
| Pricing | Upon Request |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC100A |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | USB 2.0 bidirectional communication |
| Control Architecture | ARM Cortex-M3 microcontroller |
| Calibration | Integrated standard reference materials with one-click temperature & enthalpy calibration |
| Power Supply | AC 220 V / 50 Hz |
| Brand | NANJING DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | ±600 mW |
| Baseline Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Temperature Accuracy | ±0.001 °C |
| Atmosphere Control | Dual-gas auto-switching (N₂, Air, or custom gas) |
| Flow Rate | 0–300 mL/min |
| Max Pressure | ≤5 MPa |
| Thermal Program | Up to 6 segments (heating/holding/cooling) |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300C |
| Temperature Range | −40 to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Atmosphere Control | Dual-gas auto-switching (up to 200 mL/min, ≤0.5 MPa), plus inert purge line |
| Data Interface | USB 2.0 with auto-reconnect |
| Display | 7-inch 24-bit color touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Balance Resolution | 0.01 mg |
| DSC Range | ±800 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Display | 7-inch 24-bit color touchscreen |
| Software | Integrated thermal analysis suite with TG, DTG, DSC, and TG-DSC overlay |
| Brand | NANJING DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA300 |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.001 °C |
| Max Sample Mass | 30 g |
| DSC Sensitivity | 0.001 mW |
| Mass Resolution | 0.01 mg |
| Atmosphere Control | Integrated Digital Mass Flow Controller |
| Data Interface | Standard USB |
| Power Supply | AC 220 V / 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Coupling Technology | TG-DSC |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | N₂ (digital mass flow controller) |
| Weight Resolution | 0.1 µg |
| DSC Sensitivity | ±1000 mW |
| Weighing Range | 0.01 mg–3 g (expandable to 50 g) |
| Weight Accuracy | 1 µg |
| Cooling Time (1000 °C → 50 °C) | ≤20 min |
| Temperature Resolution | 0.1 °C |
| Control Method | Intelligent PID |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Mass Range | 0.01 mg – 3 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1 – 100 °C/min |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Display | 7-inch 24-bit color touchscreen interface |
| Communication | USB 2.0 bidirectional interface with proprietary PC software |
| Compliance | Designed for GLP-compliant workflows |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–30 g |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Display | 7-inch LCD touchscreen |
| Data Interface | USB |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, and GLP-compliant reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Temperature Range | −30 °C to 200 °C |
| Accuracy | ±0.00001 W/(m·K) |
| Repeatability | ≤1% |
| Measurement Time | ≤160 s |
| Sample Forms | Solid, liquid, powder, paste, gel, thin film, and insulating materials |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Power Consumption | <300 W |
| Sample Dimensions (Solid) | ≥15 mm × 15 mm × 7.5 mm (Probe #1), ≥30 mm × 30 mm × 15 mm (Probe #2) |
| Liquid/Powder Capacity | 18 mL via dedicated fixture |
| Operating Environment | Ambient temperature, air atmosphere |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample mode |
| Test Environment | Ambient pressure |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | 25–130 °C (extendable to −40–300 °C with optional thermal chamber) |
| Sample Dimensions (min.) | 15×15×3.75 mm (Probe #1), 30×30×7.5 mm (Probe #2), 50×50×15 mm (Probe #3) |
| Probe Options | Dual-spiral planar sensors (7.5 mm, 15 mm, 50 mm diameters) |
| Power Consumption | <500 W (AC 220 V) |
| Probe Power | ≤1 W (P1), ≤20 W (P2), ≤22 W (P3) |
| Sample Form Compatibility | Solids (bulk, powder, film, coating), liquids, gels, pastes, and colloids |
| Physical Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Powder Test Kit | Optional standard container set (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Temperature Range | Ambient to 130 °C (optional extension: −40 °C to 300 °C) |
| Sample Forms | Solid, Liquid, Powder, Paste, Gel, Coating, Thin Film |
| Probe Diameters | 7.5 mm, 15 mm, 50 mm (interchangeable) |
| Measurement Time | 5–160 s (user-configurable) |
| Repeatability | ≤3% |
| Power Supply | AC 220 V, <500 W |
| Sample Dimensions (min.) | 15×15×3.75 mm (for 7.5 mm probe) |
| Compliance | ASTM D5334, ISO 22007-2, GB/T 32064–2015 |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | Ambient to 130 °C (extendable to −40 °C to 300 °C) |
| Sample Forms | Solid, Liquid, Gel, Paste, Powder, Film, Granular, Metallic, Insulating Materials |
| Probe Options | 7.5 mm, 15 mm, 50 mm diameter dual-spiral probes |
| Measurement Time | 5–160 s (user-configurable) |
| Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Power Supply | AC 220 V |
| Max. Power Consumption | <500 W |
| Probe Power Limits | ≤1 W (Φ7.5 mm), ≤20 W (Φ15 mm), ≤22 W (Φ50 mm) |
| Minimum Sample Dimensions | ≥15×15×3.75 mm (Φ7.5 mm probe), ≥30×30×7.5 mm (Φ15 mm probe), ≥50×50×15 mm (Φ50 mm probe) |
| Optional Accessories | Custom powder test cell |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | Ambient to 130 °C (extendable to 300 °C) |
| Sample Forms | Solid, Liquid, Gel, Paste, Powder |
| Probe Options | 7.5 mm, 15 mm, 50 mm diameter planar sensors |
| Measurement Time | 5–160 s |
| Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Power Supply | AC 220 V, <500 W |
| Sample Size Requirements | ≥15×15×3.75 mm (for 7.5 mm probe), ≥30×30×7.5 mm (for 15 mm probe), ≥50×50×15 mm (for 50 mm probe) |
| Compliance | ASTM D5334, ISO 22007-2, GB/T 32064–2015 |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Sample Forms | Metals, Liquids, Solids, Powders, Pastes, Gels |
| Test Duration | 5–160 s |
| Operating Temperature | Ambient to 130 °C (optional extension: −40 °C to 300 °C) |
| Probe Diameters | 7.5 mm, 15 mm, 50 mm |
| Power Supply | AC 220 V, <500 W |
| Minimum Sample Dimensions (per probe) | 15×15×3.75 mm |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample mode |
| Test Environment | Ambient pressure |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Dimensions (L×W×H) | 455 × 390 × 200 mm |
| Repeatability | ≤3% |
| Temperature Range | Room temperature to 130 °C (extendable to 300 °C with optional heating module) |
| Sample Forms | Solids (bulk, film, coating), powders, liquids, pastes, gels, and aerogels |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | Ambient to 130 °C (optional extension: −40 °C to 300 °C) |
| Sample Forms | Solids (bulk, granular, coated, thin-film), Liquids, Gels, Pastes, Powders |
| Test Duration | 5–160 s per measurement |
| Probe Options | 7.5 mm, 15 mm, and 50 mm diameter probes |
| Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Power Supply | AC 220 V, <500 W |
| Max. Probe Power | 1 W (7.5 mm), 20 W (15 mm), 22 W (50 mm) |
| Sample Size Requirements | ≥15×15×3.75 mm (7.5 mm probe), ≥30×30×7.5 mm (15 mm probe), ≥50×50×15 mm (50 mm probe) |
| Software | Integrated TPS data acquisition & thermal property calculation module with real-time curve fitting and ASTM/ISO-compliant reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient pressure |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Dimensions (L×W×H) | 455 × 390 × 200 mm |
| Repeatability | ≤3% |
| Temperature Range | Room temperature to 130 °C (extendable to –40 °C to 300 °C with optional modules) |
| Sample Forms | Solids (bulk, film, powder, paste, gel), Liquids, Coatings, Insulating materials |
| Brand | DZHAN |
|---|---|
| Model | DZ-DSC100A |
| Origin | Jiangsu, China |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Interface | USB 2.0 |
| Display | 7-inch 24-bit color TFT touchscreen |
| Power Supply | AC 220 V / 50 Hz |
| Compliance | Includes certified reference materials and one-click calibration for temperature and enthalpy |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC100A |
| Price Range | USD 4,200–7,000 (FOB) |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Sensitivity | 0.01 mW |
| Gas Flow Control | Digital Mass Flow Controller (0–200 mL/min) |
| Display | 7-inch 24-bit color capacitive touchscreen LCD |
| Communication Interface | USB 2.0 (bidirectional) |
| Sensor Material | Corrosion-resistant alloy thermopile |
| Calibration | Integrated standard reference materials (e.g., In, Sn, Zn) with one-click auto-calibration for temperature and enthalpy |
| Power Supply | AC 220 V / 50 Hz (customizable for 110 V / 60 Hz) |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel automatic switching, flow 0–200 mL/min, pressure ≤0.5 MPa |
| Thermal Program | Up to 6 segments (ramp/hold/cool), max hold time ≤24 h |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Compliance | ASTM E794, ISO 11357-1, USP <1163>, GLP-ready software audit trail |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas automatic switching (N₂, Ar, air), flow rate 0–200 mL/min, max pressure 0.5 MPa |
| Thermal Program | Up to 6-segment ramp/hold/cool sequences, isothermal duration ≤24 h |
| Display | 7-inch 24-bit color TFT touchscreen |
| Data Interface | Standard USB 2.0 |
| Calibration Standards Included | Indium, Tin, Lead |