Thermal Analysis Instruments
Filter
Showing 61–90 of 243 results
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TGA-605 |
| Temperature Range | Ambient to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Mass Sensitivity | 0.01 mg |
| Mass Repeatability | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | ±0.1 °C |
| Baseline Reproducibility | ±0.1 °C |
| Sampling Frequency | 0.05–10 Hz (programmable) |
| Dual-Temperature Sensing | Furnace & Sample |
| Control Modes | FTC (Fixed Temperature Control) & STC (Sample Temperature Control) |
| Programmable Temperature Stages | Up to 12 |
| Cycle Repetition | Up to 9999 cycles with auto-data retention |
| Atmosphere Control | Two independent gas lines with software-driven switching |
| Display | 7-inch 24-bit color LCD touchscreen |
| Cooling System | Integrated capillary water-circulation furnace jacket |
| Furnace Design | Modular ceramic insulation with dual-purge gas channels |
| Optional Exhaust Interface | Dedicated port for off-gas coupling to FTIR or MS |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Static Jacket (22 °C and 30 °C) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40 000 J |
| Cooling Medium | Tap Water |
| Cooling Flow Rate | 50–60 L/h (55 L/h at 18 °C) |
| Max Oxygen Pressure | 40 bar |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % RH |
| Protection Rating | IP20 |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Compliance | DIN 51900, ISO 1928 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol (Regnault–Pfaundler isothermal principle) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40,000 J |
| Outer Water Bath Capacity | Not specified |
| Inner Water Bath Capacity | Not specified |
| Cooling Medium | Tap water |
| Min. Coolant Flow Rate | 50–60 L/h at 18 °C |
| Max. Oxygen Pressure | 40 bar |
| Protection Rating | IP20 |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Compliance | DIN 51900, ISO 1928 |
| Interfaces | RS232 (balance, printer, PC), USB |
| Power Supply | 100–240 V, 50/60 Hz, 120 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | IKA C 3000 eco Package |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibolic Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibolic mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| Outer Water Jacket Volume | unspecified |
| Inner Water Jacket Volume | unspecified |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Sample Throughput | 4 measurements/h (isoperibol), 6 measurements/h (dynamic) |
| Heat Capacity Calibration Range | 40,000 J |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Cooling Medium | Tap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible) |
| Max. Oxygen Pressure | 40 bar |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Ambient Operating Conditions | 20–25 °C, ≤80 % RH |
| Ingress Protection | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz, 2000 W |
| Compliance Standards | DIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/12 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| External Water Jacket Volume | ~8 L |
| Internal Water Jacket Volume | ~2.5 L |
| Max. Oxygen Pressure | 40 bar |
| Cooling Medium Flow Rate | 60–70 L/h (at 18 °C) |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Rated Input Power | 2000 W |
| Protection Rating | IP20 |
| Ambient Operating Conditions | 20–25 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Country of Origin | Imported |
| Model | C 7000 Basic Equipment Set 1 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol Dry-Mode Combustion Calorimetry (ISO 1928) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i) |
| Single-Sample Test Duration | ~3–5 min |
| Heat Capacity | 30,000 J/K |
| Cooling Medium | Tap water |
| Minimum Cooling Flow Rate | 120–180 L/h |
| Max Operating Oxygen Pressure | 40 bar |
| Max Cooling Medium Pressure | 9 bar |
| Ambient Temperature Range | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz |
| Input Power | 260 W |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 50.162 kg |
| Interfaces | RS232 (balance, printer, PC), Centronics printer port |
| Oxygen Bomb Recognition | Automatic encoded detection |
| Compatible Crucibles | C14 combustion crucibles (retrofittable) |
| Software | C5040 CalWin v3.x (menu-driven, GLP-compliant data handling) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C 3000 eco |
| Calorimetric Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Measurement Time | 15 min |
| Heat Capacity Calibration Range | Up to 40,000 J |
| Outer Water Jacket Volume | Approx. 3.5 L |
| Inner Water Bucket Volume | Approx. 2.2 L |
| Operating Ambient Temperature | 20–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Rating | IP20 (DIN EN 60529) |
| Power Supply | 220–240 V, 50/60 Hz, 1700 W |
| Dimensions (W × D × H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Cooling Medium | Tap water or external chiller (e.g., RC 2 basic) |
| Oxygen Pressure | Up to 40 bar |
| Compliance Standards | ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213 |
| Data Interfaces | Ethernet, RS232, USB, SD card slot |
| Optional Accessories | C6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Modes | Adiabatic, Isoperibol (Isothermal), Dynamic |
| Temperature Range | 22–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity Calibration Range | 40,000 J |
| Cooling Circulator | RC 2 Basic |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap water |
| Min Flow Rate | 60 L/h |
| Max Flow Rate | 70 L/h |
| Ambient Operating Temp | 20–25 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 2000 W |
| Dimensions (W×D×H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | YND-OM4 |
| Temperature Range | RT to 500 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| Sample Capacity | Up to 8 samples per run (configurable for 4/6/8) |
| DSC Range | 0 to ±500 mW |
| DSC Resolution | 0.01 mW |
| DSC Sensitivity | 0.01 mW |
| Gas Control | Dual-channel mass flow control (N₂/O₂), 0–200 mL/min, accuracy ±0.2 mL/min |
| Power Supply | AC 220 V, 50 Hz |
| Interface | Integrated USB 2.0 |
| Display | 7-inch color capacitive touchscreen |
| Compliance | GB/T 19466.3–2009 / ISO 11357-3:1999 (OIT determination) |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | Kofler HB |
| Type | Hot-block melting point apparatus |
| Principle | Kofler hot-plate method (linear temperature gradient) |
| Application | Rapid qualitative and semi-quantitative melting point determination of organic crystalline solids |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | L40 EGA GC-MS |
| Temperature Range | Up to 1200 °C |
| Interface Type | Heated Capillary Transfer Line (100–350 °C) |
| GC Oven | Programmable, -10 to 350 °C |
| MS Detector | Quadrupole Mass Spectrometer (m/z 1–1000) |
| Detection Limit | <10 pg for selected ions |
| Compliance | ASTM E2892, ISO 11358-2, USP <1031>, GLP-ready data audit trail |
| Brand | MATHIS |
|---|---|
| Origin | Canada |
| Model | TC-30 |
| Measurement Principle | Transient Plane Source (TPS) or Modified Transient Hot Wire (THW) |
| Sample Measurement Time | 1–60 s |
| Inter-Test Interval | 0–10 min (typ. 2 min) |
| Operating Temperature Range | –20 °C to +60 °C (external sensor) |
| Compliance | Designed for GLP/QC environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC1 |
| Heating Rate | up to 2,400,000 K/min |
| Cooling Rate | up to 240,000 K/min |
| Sensor Type | UFS1 MEMS-based chip sensor with 16 thermocouple pairs (8 on sample side, 8 on reference side) |
| Time Constant | ~1 ms |
| Measurement Principle | Dynamic power-compensated differential scanning calorimetry |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | VHF104 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −50 to 110 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–10 °C/min |
| Frequency Range | 100–10,000 Hz |
| Force Range | ±150 N |
| Displacement Range | ±10,000 µm |
| Strain Range | 10⁻⁶–30% |
| Deformation Modes | Tension, Compression, Annular Shear |
| Standard Masses | 5, 10, 20, 40, 80, 200 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861e |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Tan δ Range | 0.0001–100 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA1 |
| Temperature Range | −190 °C to 600 °C |
| Force Range | ±0.001 N to ±10 N |
| Displacement Range | ±1 mm |
| Frequency Range | 0.001 Hz to 300 Hz |
| Stiffness Range | 50 N/m to 10⁵ N/m |
| Tan δ Range | 0.0001 to 50 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 / DP90 |
| Temperature Range | RT to 400 °C (DP70), –20 to 400 °C (DP90) |
| Accuracy | ±0.4 °C (–20 to 30 °C), ±0.2 °C (30 to 200 °C), ±0.5 °C (200 °C to max) |
| Heating Rate | 0.1–20 °C/min |
| Compliance | ASTM D3104, D3461, D36, D6089 |
| Data Output | PDF, CSV, video export, LIMS-compatible CSV |
| Sample Carrier | Standardized disposable cups per ASTM/DIN/Ph. Eur. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 2 |
| Temperature Range | –150 to 700 °C |
| Heating/Cooling Rate | 0.02 to 300 K/min |
| Sensor Type | FRS 6 (56 thermocouples) or HSS8 (120 thermocouples) |
| Autosampler Capacity | 34 positions |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 / DSC 3+ |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.05 °C |
| Heating/Cooling Rate | 0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 Excellence Series |
| Temperature Range | −150 °C to 700 °C |
| Data Acquisition Rate | Up to 50 data points per second |
| Sensor Type | MultiSTARe™ DSC sensor with 56 or 120 thermocouple pairs (Au/Au-Pd) |
| Cooling Rate | 0.02 K/min to 50 K/min |
| Calibration | FlexCal® (fully automated, multi-point, reference-based) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3+ |
| Temperature Range | -150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min |
| Sensor Options | FRS 6+ (56 thermocouples) or HSS 9+ (120 thermocouples) |
| TAWN Resolution (FRS/HSS) | 0.12/0.2 °C |
| TAWN Sensitivity (FRS/HSS) | 11.9/56 µW/°C |
| Indium Response Ratio (FRS) | >155 mW/°C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 5+ |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Capacity | Multi-sample (automated) |
| Operating Modes | Power Compensation & Heat Flux (FlexMode™) |
| Sensor Configuration | MultiStar™ sensor with 136 thermocouple pairs |
| Calibration | FlexCal™ automated calibration |
| Atmosphere Control | Integrated gas-purged crucible chamber |
| Modular Architecture | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSC Series (UV-DSC, Optical DSC, Microscope-DSC) |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1+ Microscopy System, HP DSC1+ Microscopy System |
| Temperature Range | DSC1+: −150 to 700 °C |
| HP DSC1+ | RT to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Pressure Range (HP variant) | Vacuum to 2 MPa |
| Microscope Integration | Compatible with Olympus, Leica, and other OEM optical platforms |
| Compliance | Designed for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | −150 °C to 700 °C (standard), up to 1100 °C (optional furnace) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–250 K/min |
| Heat Flow Sensitivity | 0.04 µW (FRS 5+ sensor), 0.02 µW (HSS 8+ sensor) |
| Sensor Type | MultiSTAR® DSC Sensor (56- or 120-pair Au/Au-Pd thermocouples, star-arranged on ceramic substrate with Al₂O₃ coating) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | –150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS 6+ sensor), 0.02 µW (HSS 9+ sensor) |
| Sensor Configuration | 56-pair (FRS 6+) or 120-pair (HSS 9+) Au/Au-Pd thermocouples in star geometry |
| Compliance | ASTM E794, ISO 11357, USP <1163>, FDA 21 CFR Part 11 (with optional software modules) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55 / MP70 / MP80 / MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Diameter Compatibility | <1.8 mm |
| Sample Capacity | Up to 6 samples simultaneously |
| Compliance | GLP/GMP-ready, ISO/IEC 17025-aligned calibration traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP70 / MP90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Sample Capacity | Up to 6 capillaries per run |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ISO 11357-3, ASTM D1519 |
| Safety | Integrated optical monitoring with simultaneous transmittance measurement and reflected-light imaging |
| User Interface | One Click® color touchscreen with pre-stored method recall |
| Qualification Support | Factory-supplied IQ/OQ documentation and on-site qualification services available |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | DSC |
| Temperature Range | –95 °C to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor) |
| Simultaneous Sample Measurement | Multiple |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |