Thermal Analysis Instruments
Filter
Showing 901–912 of 912 results
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PZY-III-1000 |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0–30 °C/min (programmable) |
| Displacement Resolution | 0.1 µm |
| Brand | ZHENHUAFENXI |
|---|---|
| Model | XPY |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±1 °C (at 1000 °C) |
| Sample Dimensions | Ø6–8 mm × up to 50 mm L |
| Measurement Range | ±5 mm |
| Resolution | 1 µm |
| Sample Holder Material | Fused Quartz |
| Compliance Standards | GB/T 4100–2015, GB/T 3810.9–2016 |
| Software Platform | Windows 10/7/XP |
| Brand | ZHONGHUAN FURNACE |
|---|---|
| Origin | Tianjin, China |
| Model | TA-16A01 / TA-Z1601 |
| Temperature Range | Ambient to 1600 °C |
| Heating Rate | 0–50 °C/min (adjustable) |
| Atmosphere Options | Air, Vacuum, Inert Gas, Oxidizing Atmosphere |
| Brand | Zhonglu |
|---|---|
| Model | DS C--500ARD |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Sample Capacity | 1 |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/Ar) |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB 2.0, RS-232 |
| Calibration Standards | Indium (In), Tin (Sn), α-Al₂O₃ reference material |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-500ARD |
| Price | USD 4,200 (approx.) |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 1 |
| Temperature Resolution | 0.01 °C |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas automatic switching |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB 2.0, RS-232 |
| Calibration Standards | Indium (In) and Tin (Sn), certified reference materials included |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DSC-500ARD |
| Price | USD 4,200 (approx.) |
| Temperature Range | Ambient to 500 °C ±0.1 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 1 |
| Temperature Resolution | 0.01 °C |
| DSC Signal Range | ±200 mW / ±500 mW |
| Atmosphere Control | Dual-gas automatic switching |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB, RS-232 |
| Calibration Standards | Indium and Tin reference materials included |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Model | DSC-500ARD |
| Type | Differential Scanning Calorimeter (DSC) |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Sample Capacity | 1 position |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas automatic switching (e.g., N₂/air) |
| Display | 10.1″ industrial-grade capacitive touchscreen (24-bit color) |
| Data Interfaces | USB 2.0, RS-232 |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Model | DTA-1350 |
| Temperature Range | RT to 1350 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DTA Signal Range | 0–±2000 µV |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Control Method | PID-based Programmable Temperature Control |
| Data Interface | USB 2.0 |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Sensor Material | Corrosion- and oxidation-resistant alloy |
| Atmosphere Control | Automated internal gas switching |
| Calibration Standard | Certified Sn reference material included |
| Compliance | ASTM E794, ISO 11357-1, GB/T 19466.1–2004 |
| Brand | Zhonglu |
|---|---|
| Model | TGA-1250Q |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Dynamic Weighing Range | 0.01 mg to 30 g |
| Balance Sensitivity | 0.1 μg |
| Mass Accuracy | ±0.00001 g |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | 25 ppm/10 °C |
| Baseline Drift | 25 ppm/10 °C |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static/dynamic) |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Data Interface | RS-232 |
| Compliance | Patented in China (CN Patent No. disclosed upon request) |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKDZY-I |
| Temperature Range | 200 °C |
| Heating Rate | 80 °C/min |
| Temperature Accuracy | ±1 °C |
| Stroke/Displacement Range | 1 mm |
| Measurement Resolution | 0.01 mm |
| Atmosphere Control | 12 configurable gas channels |
| Rated Power | 1 kW |
| Rated Voltage | 220 V / 50 Hz |
| Drum Internal Diameter | Φ68 mm |
| Drum Internal Height | 120 mm |
| Steel Ball Diameter | 6 mm |
| Tumbling Speed | 90 rpm |
| Programmable Tumbling Duration | Yes |
| Overall Dimensions (L×W×H) | 700 × 640 × 690 mm |
| Net Weight | 50 kg |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKTKK-700c |
| Temperature Range | 200 °C (max. 700 °C) |
| Max. Heating Rate | 80 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Ø50 mm ±1 mm × 60 mm ±1 mm |
| Measurement Range | 1 mm |
| Resolution | 0.01 mm |
| Atmosphere Control | Air (filtered, pressure-regulated, flow-controlled) |
| Flow Sensor Range | 250 L/h, ±4% FS |
| Pressure Sensor Range | 0–1 MPa, Class ≥1.5 |
| Vibration Frequency | 1 rpm |
| Rated Power | 1.5 kW |
| Voltage/Frequency | 220 V / 50 Hz |
| Device Dimensions | 750 × 700 × 1600 mm |
| Weight | 150 kg |
| Brand | Jiubin Instruments |
|---|---|
| Model | DSC-300L |
| Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C (extended capability to 1050 °C per specification) |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 µW |
| DSC Dynamic Range | ±800 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), plus dedicated purge gas line |
| Gas Flow Range | 0–300 mL/min |
| Gas Pressure Limit | ≤1 MPa |
| Display | 7-inch industrial-grade capacitive touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect protocol |
| Compliance | GB/T 19466.2–2004, GB/T 19466.3–2004, GB/T 19466.6–2009, ISO 11357-2:1999, ISO 11357-3:1999 |