Thermal Analysis Instruments
Filter
Showing 811–840 of 922 results
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 200 HT |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Repeatability | ±0.5% |
| Accuracy | ±1% |
| Temperature Range | −20 to 250 °C |
| Minimum Sample Thickness | 0.025 mm |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 200 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Repeatability | ±0.5% |
| Accuracy | ±1% |
| Temperature Range | −20 °C to +75 °C |
| Minimum Sample Thickness | 0.025 mm |
| Compliance | ASTM C518, ISO 8301 |
| Control Modes | Standalone or PC-controlled |
| Software | WinTherm™ |
| Optional Automation | Robotic Auto-sampler |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 314 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Accuracy | ±1% |
| Temperature Range | Standard –20°C to 75°C |
| Thickness Resolution | 0.025 mm |
| Sensor Type | Dual Thin-Film Heat Flux Sensors |
| Compliance | ASTM C518, ISO 8301 |
| Software | WinTherm™ v5.x |
| Automation | Optional AutoSampler for unattended operation |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 50 |
| Thermal Conductivity Range | 0.1–10 W/m·K |
| Dimensions (L×W×H) | 250×170×360 mm |
| Accuracy | ±3% |
| Temperature Range | −10°C to 110°C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 600 GHP |
| Measurement Principle | Guarded Hot Plate (GHP) |
| Compliance Standards | ASTM C177, ISO 8302, DIN EN 12667 |
| Operating Temperature Range | 90 °C to 250 °C |
| Sample Configuration | Single-specimen, symmetric arrangement |
| Thickness Measurement Method | Optical encoder-based digital displacement sensing |
| Temperature Uniformity Verification | 40 matched thermocouples |
| Thermal Stability Architecture | Dual-zone active temperature control with inert gas purge capability |
| Instrument Class | Primary-standard absolute thermal conductivity measurement system |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 600 |
| Measurement Principle | Guarded Hot Plate / Heat Flow Meter Method (ASTM C518, ISO 8301) |
| Sample Thickness Range | Down to 0.025 mm (with digital thickness measurement) |
| Sensor Type | Dual thin-film heat flux sensors |
| Temperature Control | Responsive solid-state heating/cooling system |
| Software | WinTherm™ (compliant with 21 CFR Part 11 audit trail & user access control) |
| Automation Options | Optional auto-sampler and rotary sample stage |
| Compliance | ASTM C518, ISO 8301, ISO 8302 (guarded hot plate mode), GLP/GMP-ready configuration |
| Brand | TA Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FOX 801 |
| Price | Upon Request |
| Thermal Conductivity Range | 0.001–0.35 W/m·K |
| Accuracy | ±1% |
| Temperature Range | −10 to +65 °C |
| Thickness Measurement Resolution | 0.025 mm |
| Sensor Type | Dual Thin-Film Heat Flux Sensors |
| Compliance | ASTM C518, ISO 8301 |
| Cooling/Heating Method | Solid-State Peltier |
| Control Mode | Standalone or PC-Driven (WinTherm Software) |
| Optional Accessories | Automated Sample Changer, Rotational Sample Holder |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Cell Volume | < 200 µL (capillary-based) |
| Pressure Control | Integrated solid-state linear actuator with ±0.1 psi regulation |
| Automation | Optional DSC Auto autosampler (HPLC-grade precision) |
| Brand | TA Instruments |
|---|---|
| Origin | Italy |
| Model | OPD 868 |
| Temperature Range | RT – 1650 °C |
| Heating Rate | 0.1 – 100 °C/min (up to 200 °C/sec in transient mode) |
| Temperature Accuracy | ±0.2 °C |
| Sample Length | 1 – 85 mm (mode-dependent) |
| Camera Resolution | 5 MP |
| Multi-sample Capability | Up to 8 ISO-standard specimens simultaneously |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RS-DSC |
| Sample Throughput | Multi-sample simultaneous measurement |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | 20–100 °C |
| Temperature Accuracy | ±0.02 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TAM IV |
| Simultaneous Sample Capacity | Multiple |
| Temperature Range | 4–150 °C |
| Temperature Accuracy | ±0.1 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TAM 48 |
| Simultaneous Sample Capacity | Up to 48 |
| Temperature Range | 4–150 °C |
| Temperature Accuracy | ±0.1 °C |
| Instrument Type | Isothermal Titration & Reaction Microcalorimeter |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TA-10 |
| Pricing | Upon Request |
| Max Operating Temperature | 1000 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | <1% of reading |
| Heating Rate Control | 5 ± 1 °C/min (PID-regulated, fully automated) |
| Test Method | Fiber Draw Method (ASTM C336, SJT 11039–1996, JC/T 752–1996) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CRY-2A / CRY-1A |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DSC30 |
| Temperature Range | Ambient to 750 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Stability | < ±0.1 µW over 30 min |
| Atmosphere Control | Dual-channel, 0–200 mL/min (0.1 mL/min resolution) |
| Cooling Speed | 550 °C → −40 °C in ≤35 min |
| Temperature Control Precision | < ±0.03 °C (isothermal), Linearity Error < 0.1 °C @ 10 °C/min |
| Sensor | Integrated NiCr/NiSi thermopile with symmetrical sample-stage electrodes |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Techcomp RJY-1P |
| Instrument Type | Static Thermomechanical Analyzer (TMA) |
| Temperature Range | Ambient to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Applied Load Range | Up to 250 g (static force) |
| Displacement Measurement Range | 0–2500 µm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | RZY-1 / RZY-2 |
| Price Range | USD 7,000 – 14,000 |
| Temperature Range | Ambient to 1400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 1–50 °C/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZRY-1A & ZRY-2A |
| Price Range | USD 14,000–42,000 (FOB Shanghai) |
| Heating Rate | 0.1–50 °C/min |
| Temperature Range | Ambient to 1450 °C |
| Temperature Stability | ±1.5 °C |
| Maximum Sample Mass | 2 g |
| Atmosphere Options | Inert, Oxidizing, Static, Dynamic |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themy HP TGA |
| Temperature Range | RT to 1200 °C |
| Maximum Operating Pressure | ≤150 bar |
| Balance Sensitivity | 0.023 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Mass Resolution | ≤0.03 µg |
| Sample Capacity | up to 100 g |
| Mass Dynamic Range | ±2000 mg / ±200 mg |
| Vacuum Level | <10⁻² mbar |
| Atmosphere Compatibility | O₂, H₂, CO, CO₂, CH₄, N₂, Ar, He, and reactive/corrosive gases |
| Cooling Method | Integrated water cooling (cool-down time <20 min) |
| Temperature Accuracy | ±0.1 K |
| Baseline Noise | Ultra-low, enabling high-fidelity kinetic analysis under pressure |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q5000IR, Q500, Q50 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ThermoConcept |
| Pricing | Upon Request |
| Brand | NANJING DAZHAN |
|---|---|
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static/dynamic) |
| Balance Resolution | 0.1 µg |
| Balance Accuracy | ±0.01 mg |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color touchscreen |
| Communication | USB 2.0 bidirectional interface |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, GLP-compliant report generation |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1000 |
| Temperature Range | RT–1000°C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless Steel Gas Pathway |
| Cooling | Water-Cooled Furnace |
| Software Platform | Infinity Pro for Windows |
| Compliance | ASTM E1131, ISO 11358, USP <691>, GLP-Ready |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1500 |
| Temperature Range | RT–1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless-Steel Dual-Gas Purge System |
| Software Platform | Infinity Pro for Windows |
| Optional Modules | EGA Interface with Heated Transfer Line, Auto Gas Switching, Step ISO Compliance Mode, Water-Cooled Furnace |
| Brand | Thermtest |
|---|---|
| Origin | Canada |
| Model | TLS-100 |
| Measurement Principle | Transient Line Source Method |
| Thermal Conductivity Range | 0.1–5 W/m·K |
| Thermal Resistance Range | 0.2–10 m·K/W |
| Accuracy | ±5% |
| Repeatability | ±2% |
| Measurement Duration | 120 s |
| Operating Temperature Range | −40 to 100 °C |
| Minimum Sample Dimensions | Ø50 mm × 100 mm (L) |
| Probe Diameter | 1.6 mm |
| Data Storage | Internal memory + SD card (FAT32 formatted, up to 32 GB) |
| Compliance | ASTM D5334-22 |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Weight | 1.2 kg |
| Dimensions (L×W×H) | 50 mm × 100 mm × 220 mm |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | JH50, JH70, JH90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step adjustable) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per batch |
| Display | TFT high-definition color LCD |
| Data Storage | 8 GB internal |
| Image Capture | Still frame capture with real-time video streaming |
| Video Playback | Local playback supported |
| Connectivity | USB, RS-232, Ethernet |
| Power Supply | 220 VAC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Y70 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Compliance | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | RCMK 160/260 |
| Pricing | Upon Request |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3200L |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | 0.1–15 MPa (optional pressure control) |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Sample Volume Requirement | ≥40 mL |
| Measurement Time | ≤2 s |
| Sample Forms | Liquids and gases |
| Test Atmospheres | Vacuum, air, inert gas |
| Dimensions (L×W×H) | 550×500×650 mm |
| Compliance Standards | ASTM D2717, ASTM D7896 |
| Data Interface | USB |
| Operating System | Windows |
