- All
- Favorite
- Popular
- Most rated
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 32-well, 96-well, dual 96-well, dual 384-well, and 24 × 20k Digital PCR Chip modules |
| Ramp Rate | Up to 6.0 °C/s (user-adjustable) |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (measured 20 s after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniAmp Plus |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.5 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (30 seconds after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | MiniAmp |
| Instrument Type | Standard PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 30 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | VeritiPro |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well (0.2 mL) and 384-well (0.02 mL) blocks |
| Heating Rate | 6.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.25°C (at 95°C, measured 30 s after target reached) |
| VeriFlex™ Block | 6 independently controlled thermal zones |
| Thermal Lid | 30–110°C, pressure-adjustable, auto-lift |
| Operating Voltage | 100–240 V, 50–60 Hz |
| Power Consumption | ≤700 W |
| Dimensions (H×W×D) | 21.7 × 24.5 × 46.5 cm |
| Weight | 12.0 kg |
| Environmental Requirements | 15–30°C, 15–80% RH (non-condensing) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex 2×Flat PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 96-well flat plates (0.2 mL) |
| Heating Rate | 1.6°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Inter-well Temperature Uniformity | <0.5°C (20 sec after reaching 95°C) |
| Module Configuration | Dual independent flat-block thermal modules |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ATC |
| Sample Capacity | 96-well and 384-well plates |
| Ramp Rate | 3.5°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Uniformity | ≤0.5°C (20 seconds after reaching 95°C) |
| Compliance | SiLA Rapid Integration™ certified |
| Software Interface | RESTful APIs, preconfigured for Beckman Coulter, Hamilton, and other major automation platforms |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 4°C/sec |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (measured 30 sec after reaching 95°C) |
| Thermal Control Architecture | VeriFlex™ 3-Zone Independent Peltier Module |
| Interface | Capacitive Touchscreen, USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Compatibility | Thermo Fisher Connect Cloud Platform, compatible with standard .pcr file import/export |
| Brand | Thermo Fisher |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 3500 Dx / 3500xL Dx |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Throughput | 1104 samples/day |
| Read Length Range | 30–1000 bp |
| Detection Accuracy | 99.99% |
| Detection Reproducibility | 90% |
| Run Time | 1000 reads per 120 min |
| Data Format | Capillary Electrophoresis-Based Sequencing |
| Software | Data Collection Software v3, Sequencing Analysis v6, KB Basecaller v1.4.1, Variant Reporter™, SeqScape®, GeneMapper®, GeneMapper ID-x®, MicroSEQ ID® |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COUNTESS® II FL |
| Price Range | USD 7,000 – 14,000 (FOB US) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Multiskan™ FC |
| Functionality | Absorbance-only microplate reader |
| Automation Level | Fully automated |
| Assay Modes | Endpoint and kinetic |
| Curve Fitting Options | Linear, 4-parameter logistic (4PL), 5-parameter logistic (5PL), quadratic, cubic, log-log, semi-log |
| Detector Type | Photodiode-based UV-Vis spectrophotometer |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–6.0 OD |
| Linearity | ±2% deviation from theoretical value within 0–4.0 Abs (96-well plate, standard mode) |
| Read Speed | 6 seconds per 96-well plate (fast mode) |
| Precision | CV ≤ 0.2% (0–3.0 Abs, standard mode) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CTS Xenon |
| High Voltage Range | 2500 V |
| Low Voltage Range | 500 V |
| Pulse Count | 1–10 |
| Pulse Duration | 1–30 ms |
| Output Waveform | Square Wave |