| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ProFlex™ 2 x 96-well PCR System |
| Heating Rate | 3.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (20 seconds after reaching 95°C) |
| Sample Capacity | 2 × 96-well plates |
| Instrument Type | Conventional Thermal Cycler |
| Compatible Module Options | Dual 96-well, Triple 32-well, Dual Flat Block, 96-well Fast, and Digital PCR Chip Block (for QuantStudio™ 3D) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Manufactured in China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | QuantStudio 1 Plus |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 3.5 °C/sec |
| Average Heating Rate | 1.8 °C/sec |
| Temperature Accuracy | ±0.25 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C |
| Dye Calibration | Factory-calibrated for FAM, VIC, ROX, and Cy5 fluorophores |
| Dynamic Range | 10 logs |
| Detection Sensitivity | Single-copy DNA detection |
| Concentration Discrimination | Capable of resolving 1.5-fold differences in target concentration |
| Run Time (Fast Mode) | ≤40 minutes for 40-cycle amplification |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | ProFlex 96-Well PCR System |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Throughput | 96-well format |
| Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Temperature Uniformity | <0.5 °C |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 3 × 32-well modules |
| Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (20 s after reaching 95 °C) |
| Module Options | Interchangeable 3×32-well, dual 96-well, dual-flat-block, and digital PCR chip modules |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Veriti |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 60-well, and Fast 86-well formats |
| Ramp Rate | 5.00 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 20 sec after reaching 95 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Real-Time Quantitative PCR Instrument |
| Model | QuantStudio 12K Flex |
| Sample Throughput | Supports OpenArray® plates, TaqMan® Array Cards, 384-well, 96-well, and Fast 96-well plates |
| Regulatory Compliance | FDA 21 CFR Part 11 (optional SAE module), GLP/GMP-ready architecture |
| Software Platform | Thermo Fisher Cloud with Applied Biosystems qPCR Analysis Module, ExpressionSuite v1.0, Genotyper v1.1, MeltDoctor™ HRM analysis |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | QuantStudio 7 Pro |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Maximum Heating Rate | 6.5°C/s |
| Average Heating Rate | 3.66°C/s |
| Temperature Accuracy | ±0.25°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QuantStudio 3 & QuantStudio 5 |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 384-well formats |
| Heating Rate | 3.66 °C/sec |
| Temperature Accuracy | ±0.25 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ProFlex 2×384-well PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 384-well plates |
| Ramp Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (20 sec after reaching 95 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | StepOne™ Real-Time PCR System |
| Instrument Type | Real-Time Quantitative PCR (qPCR) System |
| Sample Capacity | 48-well block |
| Optical Channels | 3-color LED-based detection system (FAM™/SYBR® Green, VIC®/JOE™, ROX™) |
| Pre-calibrated Optics | Yes |
| Software Platform | StepOne™ Software (Windows® XP/Vista®/7 compatible) |
| Data Export Format | RDML (MIQE-compliant) |
| Compliance | Supports GLP/GMP documentation workflows |
| Thermal Block Accuracy | ±0.25 °C at 95 °C |
| Block Uniformity | ±0.5 °C across all wells |
| Maximum Ramp Rate | 3.0 °C/sec (average) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Digital PCR Instrument |
| Model | QuantStudio Absolute Q |
| Sample Throughput | Up to 16 samples per run on a single MAP16 microfluidic array plate (configurable in multiples of 4: 4, 8, 12, or 16) |
| Fluorescence Channels | 5-color detection (factory-calibrated) |
| Detection Principle | Nanowell-based digital PCR using fixed-volume microfabricated wells |
| Effective Partitioning Efficiency | >95% active reaction partitions |
| Dead Volume | <5% |
| Integrated Workflow | Fully automated droplet generation, thermal cycling, fluorescence imaging, and data analysis |
| Run Time | ~90 minutes from sample loading to final quantification report |
| Software Compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 32-well, 96-well, dual 96-well, dual 384-well, and 24 × 20k Digital PCR Chip modules |
| Ramp Rate | Up to 6.0 °C/s (user-adjustable) |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (measured 20 s after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniAmp Plus |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.5 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (30 seconds after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | MiniAmp |
| Instrument Type | Standard PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 30 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | VeritiPro |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well (0.2 mL) and 384-well (0.02 mL) blocks |
| Heating Rate | 6.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.25°C (at 95°C, measured 30 s after target reached) |
| VeriFlex™ Block | 6 independently controlled thermal zones |
| Thermal Lid | 30–110°C, pressure-adjustable, auto-lift |
| Operating Voltage | 100–240 V, 50–60 Hz |
| Power Consumption | ≤700 W |
| Dimensions (H×W×D) | 21.7 × 24.5 × 46.5 cm |
| Weight | 12.0 kg |
| Environmental Requirements | 15–30°C, 15–80% RH (non-condensing) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex 2×Flat PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 96-well flat plates (0.2 mL) |
| Heating Rate | 1.6°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Inter-well Temperature Uniformity | <0.5°C (20 sec after reaching 95°C) |
| Module Configuration | Dual independent flat-block thermal modules |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ATC |
| Sample Capacity | 96-well and 384-well plates |
| Ramp Rate | 3.5°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Uniformity | ≤0.5°C (20 seconds after reaching 95°C) |
| Compliance | SiLA Rapid Integration™ certified |
| Software Interface | RESTful APIs, preconfigured for Beckman Coulter, Hamilton, and other major automation platforms |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 4°C/sec |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (measured 30 sec after reaching 95°C) |
| Thermal Control Architecture | VeriFlex™ 3-Zone Independent Peltier Module |
| Interface | Capacitive Touchscreen, USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Compatibility | Thermo Fisher Connect Cloud Platform, compatible with standard .pcr file import/export |