- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Scientific |
|---|---|
| Origin | Singapore |
| Model Numbers | A49891, A49893 |
| Measurement Time | 10 s/sample |
| Cell Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Sample Volume | 0.4 µL |
| Throughput | 2 samples |
| Detectable Cell Size | 4–60 µm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CellInsight CX7 LZR |
| Price Range | USD 480,000 – 550,000 |
| Temperature Control Module | Optional |
| Humidity & CO₂/O₂ Control | Optional (via Live-Cell Chamber) |
| Imaging Throughput | Up to 1,000 fields per hour (dependent on objective, channel count, and z-stack depth) |
| Laser Excitation Wavelengths | 405, 488, 561, 640, 785 nm (5-line solid-state laser engine) |
| Pinhole Diameters | 40 µm and 70 µm (dual-spinning-disk confocal) |
| Detector | Cooled scientific-grade CCD camera (monochrome, >95% quantum efficiency at 500–700 nm) |
| Objective Compatibility | 2× to 60×, high-NA oil/water/glycerol immersion supported |
| Software Platform | HCS Studio v3.5+ (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CellInsight CX5 |
| Price Range | USD 210,000 – 280,000 (based on configuration and regional duties) |
| Temperature Control | Not integrated (requires external environmental chamber for regulated incubation) |
| Humidity Control | Not integrated |
| Cell Analysis Throughput | Up to 500 fields of view per well (96-well plate), ~3–5 min per plate for 4-channel imaging (typical workflow) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | LCM |
| Separation Method | Automated |
| Dimensions | Compact design (32% smaller footprint vs. comparable LCM platforms) |
| Laser Configuration | Dual-solid-state laser system (IR capture + UV cutting) |
| Software | Arcturus LCM Software (5-step workflow, full instrument control, QC-integrated imaging, audit-ready metadata logging) |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | Attune Xenith |
| Technology Platform | Spectral Flow Cytometry |
| Product Category | Flow Cytometer |
| Primary Use Case | Research Applications |
| Lasers | 6 lasers (405 nm, 488 nm, 561 nm, 594 nm, 640 nm, 785 nm) |
| Detection Parameters | 57 parameters (51 fluorescence channels + 6 scatter channels) |
| Coefficient of Variation (CV) | <3% |
| Fluorescence Sensitivity | FITC ≤ 30 MESF, PE ≤ 10 MESF, APC ≤ 10 MESF |
| Acquisition Rate | >50,000 events/sec |
| Autosampler Compatibility | Yes, compatible with CytKick Max automated sample loader |
| Sample Flow Rate | 12.5–1000 µL/min |
| Compensation Method | Real-time spectral unmixing (automated and manual) |
| Voltage Adjustment Required | Yes |
| Brand | Invitrogen |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Bigfoot |
| Product Category | Flow Cytometer for Cell Analysis |
| Application Domain | Research |
| Laser Configuration | Up to 9 Lasers, 60 Parameters |
| Optical Detection Channel Resolution | <0.2 µm |
| Sample Flow Rate | Up to 200 µL/min |
| Cell Throughput | >100,000 cells/sec |
| Fluorescence Sensitivity | <100 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Fully Automated Cell Processing System |
| Model | CTS Rotea |
| Sample Volume Range | 50 mL – 20 L |
| Output Volume Range | As low as 5 mL |
| Sterility | Closed, Single-Use Disposable Kit Based |
| Regulatory Designation | Designed for Clinical and Commercial cGMP Manufacturing of Cell Therapies |
| Software Compliance | Supports 21 CFR Part 11–compliant audit trails and electronic signatures (when configured with Thermo Fisher’s DeltaV-integrated digital platform) |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Attune CytPix |
| Product Category | Imaging Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | 4 Lasers (16 Detection Channels) |
| Optical Resolution (Spatial) | 0.2 µm |
| Sample Flow Rate | 100–1000 µL/min |
| Imaging Throughput | 6,000 images/sec |
| Cell Analysis Speed | ≤65,000 events/sec |
| Fluorescence Sensitivity | FITC < 80 MESF |
| Acoustic Focusing | Yes |
| Absolute Cell Counting | Integrated |
| Clog-Resistant Fluidics | Patented |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CellInsight CX7 |
| Price Range | USD 420,000 – 490,000 (FOB) |
| Temperature Control | Not Integrated |
| Humidity Control | Not Integrated |
| Throughput Capacity | Up to 1,000 wells/hour (typical, dependent on assay configuration and imaging mode) |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | Attune NxT |
| Product Category | Flow Cytometry Analyzer |
| Application Domain | Research-Grade Cell Analysis |
| Laser Configuration | Up to 4 Lasers, 16 Parameters |
| Coefficient of Variation (CV) | <3% |
| Sample Flow Rate | 12.5–1000 µL/min |
| Maximum Acquisition Speed | 65,000 events/sec |
| Fluorescence Sensitivity | ≤30 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COUNTESS® II FL |
| Price Range | USD 7,000 – 14,000 (FOB US) |
Show next