| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | Attune Xenith |
| Technology Platform | Spectral Flow Cytometry |
| Product Category | Flow Cytometer |
| Primary Use Case | Research Applications |
| Lasers | 6 lasers (405 nm, 488 nm, 561 nm, 594 nm, 640 nm, 785 nm) |
| Detection Parameters | 57 parameters (51 fluorescence channels + 6 scatter channels) |
| Coefficient of Variation (CV) | <3% |
| Fluorescence Sensitivity | FITC ≤ 30 MESF, PE ≤ 10 MESF, APC ≤ 10 MESF |
| Acquisition Rate | >50,000 events/sec |
| Autosampler Compatibility | Yes, compatible with CytKick Max automated sample loader |
| Sample Flow Rate | 12.5–1000 µL/min |
| Compensation Method | Real-time spectral unmixing (automated and manual) |
| Voltage Adjustment Required | Yes |
| Brand | Invitrogen |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Bigfoot |
| Product Category | Flow Cytometer for Cell Analysis |
| Application Domain | Research |
| Laser Configuration | Up to 9 Lasers, 60 Parameters |
| Optical Detection Channel Resolution | <0.2 µm |
| Sample Flow Rate | Up to 200 µL/min |
| Cell Throughput | >100,000 cells/sec |
| Fluorescence Sensitivity | <100 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Attune CytPix |
| Product Category | Imaging Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | 4 Lasers (16 Detection Channels) |
| Optical Resolution (Spatial) | 0.2 µm |
| Sample Flow Rate | 100–1000 µL/min |
| Imaging Throughput | 6,000 images/sec |
| Cell Analysis Speed | ≤65,000 events/sec |
| Fluorescence Sensitivity | FITC < 80 MESF |
| Acoustic Focusing | Yes |
| Absolute Cell Counting | Integrated |
| Clog-Resistant Fluidics | Patented |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | Attune NxT |
| Product Category | Flow Cytometry Analyzer |
| Application Domain | Research-Grade Cell Analysis |
| Laser Configuration | Up to 4 Lasers, 16 Parameters |
| Coefficient of Variation (CV) | <3% |
| Sample Flow Rate | 12.5–1000 µL/min |
| Maximum Acquisition Speed | 65,000 events/sec |
| Fluorescence Sensitivity | ≤30 MESF (Molecules of Equivalent Soluble Fluorochrome) |