Empowering Scientific Discovery

Thermo Fisher Scientific Life Sciences Products

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInvitrogen
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported Instrument
ModelAttune Xenith
Technology PlatformSpectral Flow Cytometry
Product CategoryFlow Cytometer
Primary Use CaseResearch Applications
Lasers6 lasers (405 nm, 488 nm, 561 nm, 594 nm, 640 nm, 785 nm)
Detection Parameters57 parameters (51 fluorescence channels + 6 scatter channels)
Coefficient of Variation (CV)<3%
Fluorescence SensitivityFITC ≤ 30 MESF, PE ≤ 10 MESF, APC ≤ 10 MESF
Acquisition Rate>50,000 events/sec
Autosampler CompatibilityYes, compatible with CytKick Max automated sample loader
Sample Flow Rate12.5–1000 µL/min
Compensation MethodReal-time spectral unmixing (automated and manual)
Voltage Adjustment RequiredYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInvitrogen
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelBigfoot
Product CategoryFlow Cytometer for Cell Analysis
Application DomainResearch
Laser ConfigurationUp to 9 Lasers, 60 Parameters
Optical Detection Channel Resolution<0.2 µm
Sample Flow RateUp to 200 µL/min
Cell Throughput>100,000 cells/sec
Fluorescence Sensitivity<100 MESF (Molecules of Equivalent Soluble Fluorochrome)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInvitrogen
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelAttune CytPix
Product CategoryImaging Flow Cytometer
Application DomainResearch
Laser Configuration4 Lasers (16 Detection Channels)
Optical Resolution (Spatial)0.2 µm
Sample Flow Rate100–1000 µL/min
Imaging Throughput6,000 images/sec
Cell Analysis Speed≤65,000 events/sec
Fluorescence SensitivityFITC < 80 MESF
Acoustic FocusingYes
Absolute Cell CountingIntegrated
Clog-Resistant FluidicsPatented
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInvitrogen
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported Instrument
ModelAttune NxT
Product CategoryFlow Cytometry Analyzer
Application DomainResearch-Grade Cell Analysis
Laser ConfigurationUp to 4 Lasers, 16 Parameters
Coefficient of Variation (CV)<3%
Sample Flow Rate12.5–1000 µL/min
Maximum Acquisition Speed65,000 events/sec
Fluorescence Sensitivity≤30 MESF (Molecules of Equivalent Soluble Fluorochrome)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0