Total Organic Carbon Analyzer
Filter
Showing 121–129 of 129 results
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-DI1500-OL |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.000–1500.0 µg/L |
| Repeatability | ≤2% (per JB/T 20178–2017) |
| Accuracy | ±5% (per JJG (Zhejiang) 98–2007) |
| Recommended Sample Conductivity | 0–5.1 µS/cm @ 25 °C |
| Analysis Cycle Time | 4 minutes |
| Sample Flow Rate | 0.5 mL/min |
| Dimensions | 240 × 340 × 160 mm |
| Enclosure Rating | IP65 |
| Interface | RS485/Ethernet for multi-unit centralized control |
| Data Integrity Features | Electronic Signatures, Audit Trail, User Access Levels |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-WOT100 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Sample Injection Volume | 0.5–20.0 mL (recommended: 5.0 mL) |
| Measurable TOC Range | 0–100 mg/L |
| Repeatability Error | ≤3% (at 50% of full scale per JJG 821–2005) |
| Accuracy (TC) | ±5% |
| (IC) | ±4% (at 20%, 50%, and 80% of full scale per JJG 821–2005) |
| Detection Limit | ≤25 ppb (per HJ 501–2009) |
| Dimensions | 550 × 450 × 530 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | SSE-10000 |
| Maximum Sample Carbon Load | 0.1–30.0 mg C |
| Sample Form Compatibility | Solid and Liquid |
| Oxidation Efficiency | ≥99% |
| Repeatability (RSD) | ≤5% |
| Dimensions | 800 × 310 × 270 mm |
| Brand | Tekmar |
|---|---|
| Origin | USA |
| Model | Fusion |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV Light + Sodium Persulfate |
| Measurement Range | 0.2 ppb C to 4,000 ppm C |
| Accuracy | ±1% |
| Detection Limit | 0.2 ppb C |
| Precision (RSD) | ≤1% |
| Regulatory Compliance | EPA Methods 415.1–415.3, 9060A |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Detection Limit | 50 ppb |
| Linear Range | 0–20,000 ppm (with 0.5 mL injection volume) |
| Compliance Standards | EPA 415.1/415.3/9060A, ISO 8245, EN 1484, USP <643>, ASTM D2579, SM 5310B, HJ 501-2009, GB/T 32116-2015, AOAC 973.47 |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Detection Limit | 500 ppb |
| Quantification Range | 50 ppb – 30,000 ppm |
| Compliance | HJ 501–2009, GB/T 32116–2015, EPA Methods 415.1, 415.3, and 9060A, Standard Methods 5310B, ISO 8245, EN 1484, USP <643>, ASTM D2579, AOAC 973.47 |
| Brand | Teledyne Tekmar |
|---|---|
| Origin | Imported |
| Model | Fusion |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Detection Limit | 0.2 ppb |
| Compliance | FDA 21 CFR Part 11, USP <643>, EP 2.2.44, JP, ASTM D4779/D4839, EPA Methods 415.1–415.3 & 9060A, Standard Method 5310C, prENV 13370, GB/T 11446.8-2013 |
| Software | User-Definable Reporting, Pre-Programmed Application Methods, Automated Calibration & Dilution, Self-Diagnostic Suite (Leak Detection, Flow Verification), Mass Flow Control |
| Brand | Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPERT-TOC/TNb |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–35,000 µg/L (ppb–ppm) |
| Accuracy | RSD < 1% |
| Resolution | 0.0001 µg/L |
| Detection Limit | 3 ppb (TOC) |
| Repeatability | RSD < 1% |
| Sample Introduction | Valve-Free Funnel-Tec™ Technology |
| Combustion Tube | ProCat™ High-Efficiency Catalytic Oxidation Tube |
| Autosampler | Integrated 65-Position Liquid Autosampler with On-Deck Stirring & Removable Tray |
| Software | TEIS v5.x (Compliant with FDA 21 CFR Part 11, GLP/GMP Audit Trail) |
| Brand | UIC (United Instrumentation Corporation) |
|---|---|
| Origin | USA |
| Model | CM130 |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–10,000 µg C |
| Accuracy | ±0.2% (for 1,000–3,000 µg C samples) |
| Resolution | 0.01 µg C |
| Detection Limit | 0.01 ppm C |
| Repeatability | ≤3% RSD |
| Compliance | ASTM D4129 |