Total Organic Carbon Analyzer
Filter
Showing 61–90 of 129 results
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photocatalytic Oxidation (with TiO₂-coated quartz tube) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temperature Range | 1–99 °C |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped traceability |
| User Access Control | 4-tier role-based authentication compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen interface |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temperature Range | 1–99 °C |
| Data Logging | 5000+ records |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier password authentication compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 OL Offline |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 1–1000 ppb C |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb C |
| Resolution | 1 ppb C (full range) |
| Repeatability | ±3% RSD |
| Compliance | Designed to meet Chinese Pharmacopoeia 2020 Edition (ChP), USP <643>, and EP 2.2.44 requirements for offline water quality testing |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 Offline |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation (TiO₂-coated Quartz Tube) |
| Measurement Range | 1–1000 ppb (0.001–1.0 mg/L) |
| Accuracy | ±3% of reading |
| Resolution | 1 ppb (0.001 mg/L) |
| Detection Limit | 1 ppb (0.001 mg/L) |
| Repeatability | ≤3% RSD |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temp. Range | 1–99 °C |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped traceability |
| User Access Control | 4-tier role-based authentication compliant with FDA 21 CFR Part 11 |
| Display | Color TFT touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0/TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb (as C) |
| Resolution | 1 ppb (as C) |
| Repeatability | ±3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤5 min per sample |
| Power Supply | 220 V AC |
| Display | Color TFT Touchscreen |
| Data Storage | Internal memory for ≥10,000 test records |
| Compliance | Meets Chinese Pharmacopoeia 2020 Edition (ChP) Chapter 0682 requirements for purified water and WFI |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 µg/L (ppb) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 µg/L |
| Resolution | 1 µg/L |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <5 minutes per sample |
| Display | Color TFT Touchscreen |
| Power Supply | 220 V AC |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.1 |
| Instrument Type | Benchtop Offline TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photocatalytic Oxidation (185/254 nm) |
| Measurement Range | 1–1000 ppb (0.001–1.0 mg/L) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb (0.001 mg/L) |
| Repeatability | ≤3% RSD |
| Resolution | 0.001 mg/L |
| Analysis Time | <5 minutes per sample |
| Sample Temperature Range | 1–99 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Data Logging | ≥5000 records with time-stamped audit trail (16 event categories) |
| User Access Control | 4-tier password-protected authentication |
| Compliance | Designed to support FDA 21 CFR Part 11, USP <643>, EP 2.2.44, and ChP 2020 Edition General Chapter 0682 requirements |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TOC100 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–10,000 mg/L |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Compliance | Designed for ISO 8469, ASTM D5905, USP <643>, and EPA Method 415.3 environments |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 |
| Instrument Type | Online/Offline TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | Continuous analysis mode |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 5–65 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Conductivity Detection Range | 0.055–8.000 µS/cm |
| Response Time | ≤5 minutes |
| Data Storage Capacity | >5000 records |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier role-based authentication (username/password), compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen interface |
| Connectivity | Ethernet port, RS-232 serial port, digital power output port |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 Online & Offline 2.0 |
| Instrument Type | Online/Offline Dual-Mode TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185 nm + 254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb (as C) |
| Repeatability | ≤3% RSD |
| Resolution | 1 ppb |
| Conductivity Detection Range | 0.055–8.000 µS/cm |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 5–65 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Data Storage Capacity | >5000 measurement records |
| Audit Trail | 16+ event log categories with timestamped traceability |
| User Access Control | 4-tier role-based authentication (username/password) compliant with FDA 21 CFR Part 11 |
| Connectivity | Ethernet port, RS-232 serial interface, analog power output |
| Display | Color touchscreen interface |
| Data Export | USB flash drive support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±4% of reading |
| Resolution | 1 ppb |
| Detection Limit | 1 ppb |
| Repeatability | ≤3% RSD |
| Conductivity Range | 0.055–8.000 µS/cm |
| Sample Temp. | 1–95 °C |
| Ambient Temp. | 5–65 °C |
| Power | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Compliance | USP <643>, EP 2.2.44, FDA 21 CFR Part 11 (Audit Trail & User Authentication), GLP/GMP-ready |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 |
| Instrument Type | Online/Offline Dual-Mode TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Conductivity Detection Range | 0.055–8.000 µS/cm |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 5–65 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Data Storage Capacity | >5000 measurement records |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier role-based authentication (compliant with FDA 21 CFR Part 11) |
| Interface Ports | Ethernet, RS-232, analog power output |
| Display | Color TFT touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis |
| Measurement Range | 1–1000 ppb |
| Accuracy | ±3% |
| Resolution | 1 ppb |
| Detection Limit | 1 ppb |
| Repeatability | ±3% |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Conductivity Range | 0.055–8.000 µS/cm |
| Sample Temp. | 1–95 °C |
| Ambient Temp. | 5–65 °C |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped queries |
| User Access | 4-tier role-based authentication compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 |
| Instrument Type | Online/Offline Dual-Mode TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Conductivity Detection Range | 0.055–8.000 µS/cm |
| Analysis Time | ≤5 min per cycle |
| Sample Temp. Range | 1–95 °C |
| Ambient Operating Temp. | 5–65 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400×240×270 mm |
| Weight | 8.5 kg |
| Data Storage | ≥5000 records |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier role-based authentication |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TOC-TA-200 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–30,000 mg/L |
| Accuracy | ±3% |
| Detection Limit | 1 ppb |
| Resolution | 1 ppb |
| Repeatability | ±3% |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-200 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–30,000 mg/L |
| Accuracy | ±3% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-3.0 Online |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±3% of reading |
| Resolution | 1 ppb |
| Detection Limit | 1 ppb |
| Repeatability | ≤3% RSD |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Conductivity Detection Range | 0.055–8.000 µS/cm |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 5–65 °C |
| Data Logging Capacity | >5000 records |
| Audit Trail | 16 configurable event logs with timestamped access |
| User Access Control | 4-tier role-based authentication (username/password), compliant with FDA 21 CFR Part 11 |
| Display | Color TFT touchscreen (7-inch) |
| Dimensions (L×W×H) | 300 × 210 × 250 mm |
| Weight | 8.5 kg |
| Enclosure Material | 304 stainless steel |
| IP Rating | IP54 (splash-resistant) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-3.0 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Conductivity Detection Range | 0.055–8.000 µS/cm |
| Response Time | ≤5 minutes |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 5–65 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Data Logging Capacity | >5,000 records |
| Audit Trail | 16-event timestamped log |
| User Access Control | 4-tier role-based authentication (compliant with FDA 21 CFR Part 11) |
| Display | Color TFT touchscreen (7-inch) |
| Dimensions (L×W×H) | 300 × 210 × 250 mm |
| Weight | 8.5 kg |
| Enclosure Material | 304 stainless steel |
| IP Rating | IP54 (splash-resistant) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-3.0 Online |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb |
| Resolution | 1 ppb |
| Repeatability | ±3% RSD |
| Conductivity Detection Range | 0.055–8.000 µS/cm |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 5–65 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Data Logging | >5000 records with timestamp |
| Audit Trail | 16-event log with time-stamped user actions |
| User Access Control | 4-tier role-based authentication (compliant with FDA 21 CFR Part 11) |
| Display | Color TFT touchscreen (7-inch) |
| Dimensions (L×W×H) | 300 × 210 × 250 mm |
| Weight | 8.5 kg |
| Enclosure Material | 304 stainless steel |
| IP Rating | IP54 (splash-resistant) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-3.0 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1500 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 1 ppb |
| Repeatability | ±3% RSD |
| Conductivity Range | 0.055–8.000 µS/cm |
| Response Time | ≤5 minutes |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 5–65 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Data Logging | ≥5000 records |
| Audit Trail | 16-event timestamped log |
| User Access Control | 4-tier role-based authentication (compliant with FDA 21 CFR Part 11) |
| Display | Color touchscreen (7-inch) |
| Dimensions (L×W×H) | 300 × 210 × 250 mm |
| Weight | 8.5 kg |
| Enclosure Material | 304 stainless steel |
| IP Rating | IP54 (splash-resistant) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-5.0 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (Static Oxidation) |
| Measurement Range | 1–1500 ppb (0.001–1.5 mg/L) |
| Accuracy | ±5% |
| Detection Limit | 1 ppb (0.001 mg/L) |
| Resolution | 1 ppb |
| Repeatability | ±3% |
| Sample Temperature Range | 0–100 °C |
| Conductivity Range | 0.055–6.000 µS/cm |
| Ambient Operating Temperature | 5–65 °C |
| Relative Humidity | ≤85% |
| Power Supply | 220 V ±10%, 50 Hz ±10% |
| Response Time | <5 minutes |
| Drift | ±5% FS/24 h |
| Rated Power per Sensor Unit | 50 W |
| Communication Interface | RS-485 |
| Display | 10-inch capacitive touchscreen |
| Sample Inlet/Outlet Tubing | 1 mm ID PTFE tubing with 50-quick-connect fittings |
| Data Terminal | TOC-S500 (supports up to 8 TA-5.0 sensor units) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | T 2.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.1–1000 µg/L (ppb) |
| Accuracy | ±3% of reading |
| Detection Limit | 0.1 µg/L |
| Resolution | 0.001 µg/L |
| Repeatability | ≤3% RSD |
| Response Time | <5 minutes |
| Sample Temperature Range | 1–95 °C |
| Power Supply | 220 V AC |
| Display | Color TFT Touchscreen |
| Data Storage | Internal high-capacity flash memory with timestamped audit trail |
| Compliance | Meets Chinese Pharmacopoeia (ChP) 2020 Edition Chapter 0682 requirements for TOC testing |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TOC TA-1.0 |
| Instrument Type | Benchtop Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation (TiO₂-coated Quartz Tube) |
| Measurement Range | 1–1000 ppb (0.001–1.0 mg/L) |
| Accuracy | ±3% |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Resolution | 0.001 mg/L |
| Analysis Time | <5 minutes per sample |
| Sample Temperature Range | 1–99 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier role-based authentication |
| Compliance | FDA 21 CFR Part 11, Chinese Pharmacopoeia (2020 Ed.), ISO 8573-7, USP <643> |
| Connectivity | USB for data export, optional RS-232/485 |
| Display | Color touchscreen interface |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TOC-1.0 |
| Instrument Type | Laboratory Offline TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photocatalytic Oxidation (TiO₂-coated Rotating Quartz Tube + 185/254 nm UV Lamps) |
| Measurement Range | 1–1000 ppb (0.001–1.0 mg/L) |
| Accuracy | ±3% of reading |
| Detection Limit | 0.001 mg/L |
| Resolution | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Sample Temperature Range | 1–99 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Data Storage | ≥5000 test records with time-stamped audit trail |
| Compliance | Meets Chinese Pharmacopoeia (ChP) 2020 Edition, USP <643>, EP 2.2.44, and FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TOC5.0 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (Static UV Oxidation) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±5% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±5% RSD |
| Sample Temperature Range | 0–100 °C |
| Conductivity Range | 0.055–6.000 µS/cm |
| Environmental Operating Temperature | 5–65 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | 220 V ±10%, 50 Hz ±10% |
| Response Time | <5 minutes |
| Drift | ±5% FS/24 h |
| Rated Power per Detection Unit | 50 W |
| Sample Inlet/Outlet Tubing | 1 mm ID PTFE tubing with 50-series quick-connect fittings |
| Communication Interface | RS-485 (supports up to 8 detection units per TA-D500 data terminal) |
| Display | 10-inch capacitive touchscreen HMI |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 1030S |
| Compatibility | Requires coupling with OI Analytical Aurora 1030W, 1030C, or 1030D TOC Analyzer |
| Sample Mass Range | 50 µg – 2 g |
| TC/TOC Quantification Range | 0.05 mg – 50 mg |
| Design | Vertical compact footprint |
| Gas Capture Method | Sealed sample bag system for post-combustion CO₂ retention and sequential analysis |
| Brand | OI Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DI1000 |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 1 Hz |
| Rated Power | 100 W (max), 40 W (standby) |
| Dimensions | 440 mm × 180 mm × 260 mm |
| Weight | 10 kg |
| Detection Limit | 0.001 mg/L |
| Quantification Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Repeatability | ≤3% |
| Zero Drift | ±5% |
| Span Drift | ±5% |
| Linearity | ±5% |
| Analysis Time | 4 min per sample |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% RH |
| Display | 320 × 234 pixel full-color TFT LCD |
| Communication Interfaces | RS-232, built-in thermal printer port |
| Data Storage | 12-month continuous logging with date/time stamping |
| Compliance | USP <643>, Ph. Eur. 2.2.44, ChP TOC method |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 1030W |
| Detection Principle | High-Temperature Catalytic Oxidation (680 °C) + Solid-State Nondispersive Infrared (SSNDIR) Detection |
| Measurement Range | 2 ppb to 30,000 ppm C |
| Sample Types | Liquid aqueous matrices including suspended solids |
| Oxidation Method | Dual-channel wet chemical oxidation (optional) |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail |
| Interface | Integrated Windows CE OS with touchscreen GUI |
| Connectivity | Ethernet-enabled for LAN integration |
| Automation | Optional 88-position rotary autosampler with magnetic stirring or >96-position XYZ autosampler with priority/random sampling |
| Optional Features | Electronic Pressure Control (EPC), Electronic Flow Control (EFC), NPOC/TC/TIC/TOC quantification modes |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 1080 |
| Oxidation Method | High-Temperature Catalytic Combustion (680–950 °C) |
| Detector | Solid-State Non-Dispersive Infrared (SSNDIR) |
| Detection Range | TC: 50 ppb–2000 ppm |
| Precision | RSD < 3% |
| Sample Injection Volume | 50 µL–2 mL (adjustable in 10 µL increments) |
| Compliance | ASTM D7573, USP <643>, EPA Methods 415.3 & 9060A, ISO 8245 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TOC-4200 |
| Instrument Type | Online TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Detection Principle | NDIR (Non-Dispersive Infrared) CO₂ Detection |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (auto-ranging) |
| Cycle Time | Minimum 4 minutes per analysis |
| Carrier Gas | High-Purity Nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, Indoor Installation Only |
| Calibration | Auto-zero & span calibration |
| Sample Handling | Integrated high-speed rotary homogenizer |
| Internal Cleaning | Scheduled distilled-water flush of fluidic pathways |
| Interface | Full-color capacitive touchscreen |
| Communication | MODBUS RTU over RS-232/RS-485, 4–20 mA analog output, digital I/O |
