Total Organic Carbon Analyzer
Filter
Showing 91–120 of 129 results
| Brand | Shimadzu |
|---|---|
| Model | TOC-4200 |
| Measurement Principle | Catalytic Combustion Oxidation + NDIR CO₂ Detection |
| Oxidation Temperature | 680 °C |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (selectable) |
| Accuracy | ±1.0% of reading |
| Detection Limit | 0.01 ppm |
| Resolution | 0.001 ppb |
| Repeatability | ≤1% RSD |
| Analysis Cycle | Minimum 4 minutes |
| Carrier Gas | High-purity nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, indoor installation only |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-5000A |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±4% |
| Detection Limit | 0.005 ppm C |
| Resolution | 0.001 ppb C |
| Repeatability | ≤3% RSD |
| Sample Types | Liquid (aqueous), Solid (soil, sludge, sediment, wipe samples), Suspended Solids-Rich Water |
| Compliance | Designed for GLP/GMP environments with audit-ready operation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TOC-L |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion Oxidation (680 °C) |
| Measurement Range | 4 μg/L to 30,000 mg/L |
| Detection Principle | CO₂ quantification via Non-Dispersive Infrared (NDIR) detection after catalytic combustion |
| Power Savings | Up to 36% vs. prior generation (8 h/day, 5 days/week) |
| Footprint Reduction | Width reduced from ~440 mm to 340 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | TOC-L |
| Price Range | USD 13,500 – 27,000 (FOB Japan) |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion Oxidation |
| Oxidation Temperature | 680 °C |
| Measurement Range | 4 µg/L to 30,000 mg/L as C |
| Detection Method | NDIR (Non-Dispersive Infrared) |
| Sample Types | Liquid aqueous matrices including ultrapure water, wastewater, seawater, and industrial process water |
| Compliance | Designed to meet ASTM D7573, ISO 8245, USP <643>, and EP 2.2.44 requirements |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-V |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±4% |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.005 ppm C |
| Repeatability | ≤3% RSD |
| Detection Principle | Catalytic Combustion Oxidation + NDIR Detection |
| Sample Introduction | Programmable 8-Channel Syringe Pump |
| IC Removal | Automated Acidification + Sparging (NPOC Mode) |
| Blank Water Generation | Onboard Deionized Water Purification System |
| Compliance | Designed to support ASTM D7573, ISO 8245, USP <643>, and EPA Method 415.3 workflows |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 500RL |
| Detection Range | 0.03–2,500 ppb as C |
| Accuracy | ±5% |
| Precision | ≤0.03 ppb (for <3 ppb) or ≤1% RSD (for ≥3 ppb) |
| Conductivity Measurement Range | 0.01–35 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm (≤0.25 µS/cm) or ±2% (>0.25 µS/cm) |
| Conductivity Precision | <0.25% RSD |
| Max Acceptable Sample Conductivity | 25 µS/cm at 25°C (neutral pH) |
| Ozone Tolerance | 200 ppb |
| Operating Temperature Range | 1–95°C (steam-tolerant for short durations) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 900 |
| Detection Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% |
| Precision | <1% RSD |
| Oxidation Method | UV/Persulfate |
| Detection Method | Membrane Conductivity |
| Sample Pressure | up to 250 psi |
| Flow Rate | 30–300 mL/min |
| Sample Temperature | 1–95 °C |
| Analysis Time | 4 min (standard), 4 s (rapid module) |
| IP Rating | IP65 |
| Compliance | US EPA Method 5310C, US EPA 415.3, ASTM D7573 |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | CheckPoint |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis |
| Measurement Range | 0.21–1000 ppb C |
| Accuracy | ±5% |
| Resolution | 0.01 ppb C |
| Detection Limit | 0.21 ppb C |
| Repeatability | RSD < 1% |
| Analysis Time (Online Mode) | 15 s – 8 h (configurable) |
| Analysis Time (Grab Sample Mode) | 10 min |
| Calibration Interval | 6 months |
| Data Storage Capacity | 28,800 records |
| Connectivity | Ethernet, Modbus RTU/TCP |
| Compliance Support | IQ/OQ/PQ protocols available |
| Regulatory Context | Designed for compliance with USP <643>, EP 2.2.44, ASTM D5905, and FDA 21 CFR Part 11-ready data integrity architecture |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CheckPoint |
| Pricing | Available Upon Request |
| Detection Range | 0.05–1,000 ppb C |
| Precision | Greater of <1% RSD or 0.05 ppb (online, 20–40 °C) |
| Analysis Modes | Online continuous averaging, online timed sampling, offline grab sampling |
| Analysis Time | 15 s (online), 10 min (grab) |
| TOC Calibration Interval | 6 months |
| Conductivity Tolerance | Up to 1.4 µS/cm (0.7 MΩ·cm) CO₂-compensated conductivity |
| Conductivity Precision | ±0.5% RSD (20–40 °C) |
| Conductivity Accuracy | ±2.0% |
| Conductivity Calibration Interval | 6 months |
| Operating Pressure (Online) | 15–100 psi |
| Low-Pressure Sampling | Max. 0.70 m head above analyzer |
| Minimum Online Flow Rate | >60 mL/min |
| Power Supply | 100–240 V ±10%, 60 W, 50/60 Hz |
| Sample Temperature Range | 10–90 °C |
| Ambient Operating Temperature | 10–40 °C |
| Enclosure Rating | Indoor use only |
| I/O Options | Ethernet, 2 analog outputs, 2 alarm outputs, parallel inputs |
| Installation Category | Overvoltage Category II |
| Dimensions (H×W×D) | 25.4 × 30.48 × 15.24 cm (standard) |
| Weight | 2.9 kg (no battery), 3.58 kg (with battery), +0.6 kg (vial sampler) |
| Safety Certifications | CE, ETL Listed |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Sievers InnovOx Lab |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.05 ppm – 50,000 ppm TOC |
| Accuracy | ±3% |
| Resolution | 0.05 ppm |
| Detection Limit | 0.05 ppm |
| Repeatability | RSD ≤ 1.5% |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx Laboratory |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.05–50,000 ppm TOC |
| Accuracy | ±3% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.05 ppm |
| Repeatability | ±3% |
| Regulatory Compliance | US EPA Methods 415.1, 415.3, 9060A |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx |
| Detection Range | 0.05–50,000 ppm TOC |
| LOD | 0.05 ppm TOC |
| Accuracy | ±3% at 50 mg/L NPOC |
| Precision | RSD <5% at 50 mg/L NPOC |
| Linearity | R² >0.995 |
| Analysis Time | 2.2–7.3 min |
| Calibration Stability | 6 months |
| Particle Tolerance | <800 µm |
| Operating Temp | 10–40 °C |
| Sample Temp | 10–60 °C |
| Humidity | ≤95% RH (non-condensing) |
| Power | 100–240 VAC ±10%, 400 W, 50/60 Hz |
| Dimensions | 52.05 × 32.26 × 58.42 cm |
| Weight | 22.4 kg |
| Interface | Ethernet + 3 USB ports |
| Display | Color touchscreen |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers M500 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV Oxidation |
| Measurement Range | 0.03–2500 ppb |
| Accuracy | ±5% of reading or ±0.01 ppb (whichever is greater) |
| Resolution | 0.03 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ±5% of reading or ±0.01 ppb (whichever is greater) |
| Analysis Time (Continuous Mode) | 6 minutes |
| Sample Flow Rate | 0.25 mL/min |
| External Flow Rate | 50 mL/min |
| Sample Temperature Range | 1–95 °C (steam-tolerant for short-term exposure) |
| Max. Inlet Pressure | 100 psi |
| Conductivity Tolerance | 0.01–800 µS/cm |
| Calibration Stability | Up to 12 months without recalibration |
| Display | 10-inch color touchscreen |
| Enclosure Rating | IP55 |
| Power Supply | 100–240 VAC (+10%), 50/60 Hz, 50 W |
| Operating Environment | Indoor use only |
| Safety Certifications | ETL, CE |
| Dimensions (H×W×D) | 43.4 × 55.9 × 28.7 cm |
| Weight | 16.3 kg |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Regulatory Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C Online |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Instrument Type | Online TOC Analyzer |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C Portable |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M9 Laboratory |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Communication Interfaces | USB, 4–20 mA, Modbus TCP/IP |
| Enclosure Rating | Dust- and Splash-Resistant (for online/portable variants) |
| Design | Modular, Touchscreen Dashboard, Reagent-Free Operation (no external gases or hazardous chemicals required) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M9 Online |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Enclosure Rating | IP54 (Dust- and Splash-Resistant) |
| Communication Interfaces | USB, 4–20 mA, Modbus TCP/IP |
| Regulatory Compliance Support | USP <643>, EP 2.2.44, ASTM D5903, ISO 8245, FDA 21 CFR Part 11 (audit trail & electronic signature ready), GLP/GMP data integrity architecture |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers M9 Portable Analyzer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | RSD < 1% |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Data Interfaces | USB, 4–20 mA, Modbus TCP/IP |
| Enclosure Rating | Dust- and splash-resistant |
| Regulatory Compliance | Designed for USP <643>, EP 2.2.44, ASTM D7573, ISO 8245, and FDA 21 CFR Part 11–ready data integrity workflows |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers M9 SEC Portable |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ≤1% RSD |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ASE-18C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Rated Power | 40 W |
| Sample Capacity | 18 vials per cycle |
| Dimensions | 380 × 320 × 340 mm (W × D × H) |
| Compatible TOC Analyzers | HTY-DI1000-PL, HTY-DI1500, HTY-GM2000, HTY-GM3000 |
| Operating Modes | Analyzer-Synchronized (Online) Mode & Time-Based (Scheduled) Mode |
| Bottle Detection | Integrated optical/vacuum-based presence sensing |
| Maintenance Requirement | Minimal |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ASE-24 |
| Pricing | Upon Request |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Rated Power | 40 W |
| Sample Capacity | 24 vials per cycle |
| Dimensions | 380 × 320 × 340 mm |
| Compatible TOC Analyzers | HTY-DI1000-PL, HTY-DI1500, HTY-GM2000, HTY-GM3000 |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ASE-70A |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Rated Power | 40 W |
| Sample Capacity | 70 vials per run |
| Dimensions (W × D × H) | 300 mm × 520 mm × 450 mm |
| Compatible TOC Analyzers | HTY-DI1000-PL, HTY-DI1500, HTY-GM2000, HTY-GM3000 |
| Operation Modes | Analyzer-Synchronized (Online) & Time-Based (Scheduled) |
| Bottle Detection | Integrated optical/vacuum-sense auto-detection |
| Position Feedback | Real-time bottle-position display with auto-reset function |
| Maintenance Requirement | Minimal routine maintenance |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | C100 |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Sample Volume Range | 1–100 mL (customizable) |
| TOC Measurement Range | 0–1000 mg/L |
| Oxidation Efficiency | ≥99% |
| CO₂ Absorption Efficiency | ≥95% |
| Analysis Time | 2–60 min (programmable per sample volume) |
| Detection Limit | 0.1 µg C |
| Maximum Permissible Error | ±5% |
| Repeatability (RSD) | ≤5% |
| Dimensions | 700 × 500 × 500 mm |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC200 / DC200e |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.030–2000 ppb |
| Accuracy | ±0.1 ppb (0.100–1.99 ppb, water resistivity >15 MΩ·cm) |
| Detection Limit | 0.030 ppb |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GM200 / GM200e |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| TOC Range | 0.000–30.000 mg/L |
| IC Range | 0.000–5.000 mg/L |
| Repeatability Error | ≤2% (per JB/T 20178–2017) |
| Max. Permissible Error | TC ±5%, IC ±4% (per JJG 821–2005) |
| Analysis Time | 2.5 min |
| Dimensions | 400 mm × 400 mm × 200 mm |
| Ingress Protection | IP65 |
| Data Integrity | Audit Trail Enabled |
| User Access Control | Four-Tier Password Authentication |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HTY-GM2000 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.000–20.000 mg/L |
| Repeatability | ≤3% |
| Sample Volume Requirement | 12 mL per analysis |
| Analysis Time | ≤20 min per sample |
| Detection Limit | <10 µg/L |
| IC Range | 0.000–5.000 mg/L |
| Accuracy (Indicated Value Error) | ±5% |
| Injection Speed | 0.6 mL/min |
| Dimensions | 480 × 300 × 540 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Sample Volume Range | 0.1–1.0 mL (recommended: 0.3 mL) |
| Measurable TOC Range | 0–1000 mg/L |
| Repeatability | ≤3% (at 50% of full scale, per JJG 821–2005) |
| Accuracy | TC ±5%, IC ±4% (at 20%, 50%, and 80% of full scale, per JJG 821–2005) |
| LOD | ≤0.1 mg/L (per HJ 501–2009) |
| LOQ | ≤0.5 mg/L (per HJ 501–2009) |
| Maximum Salt Tolerance | ≤90 g/L |
| Dimensions | 650 × 450 × 495 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation |
| Detection Range | 0.000–1000.0 µg/L |
| Repeatability | ≤2% (per JB/T 20178–2017) |
| Accuracy | ±5% (per JJG (Zhejiang) 98–2007) |
| Recommended Sample Conductivity | 0–5.1 µS/cm @ 25 °C |
| Analysis Time | 4 min |
| Sample Flow Rate | 0.5 mL/min |
| Dimensions | 400 × 300 × 300 mm |
| User Interface | Full-touchscreen LCD |
| Security | Multi-level password access control |
| Alarm Function | Audible alert upon exceeding user-defined TOC upper limit |
| Optional Accessory | Modular autosampler compatibility |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.500 mg/L |
| Accuracy | ±3% |
| Resolution | 1 ppb |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤±3% |