Tribological Tester
Filter
Showing 61–90 of 122 results
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | NMC-II |
| Pricing | Available Upon Request |
| Motor | 60 W, 220 V, 50 Hz |
| Rotational Speed Range | 0–54 rpm |
| Abrading Head Load | 1000 g (standard) |
| Optional Weights | 250 g, 500 g |
| Dimensions (L×W×H) | 260 × 240 × 340 mm |
| Net Weight | 20 kg |
| Brand | Norman Tool |
|---|---|
| Origin | USA |
| Model | 7-IBB-CC |
| Load Options | 55 g, 175 g, 275 g |
| Rotational Speed | 16 rpm (50 Hz) / 18 rpm (60 Hz) |
| Counter Type | Digital LCD (0–999,999 cycles) |
| Sample Mounting | Flat & 3D fixtures included |
| Power Supply | 220 V, 50/60 Hz, 5 A |
| Weight | ~17 kg |
| Compliance | ASTM F2357-04, DIN-compatible abrasion evaluation |
| Brand | Norman Tool |
|---|---|
| Origin | USA |
| Model | 7-IBB-CC |
| Load Options | 55 g, 175 g, 275 g |
| Counter Type | Digital LCD (0–999,999 cycles) |
| Sample Mounting | Flat & 3D fixtures |
| Compliance | ASTM F2357-04 |
| Power Supply | 220 V, 50/60 Hz, 5 A |
| Weight | ~17 kg |
| Accessories | Calibration plate (certified), surface level gauge, hex key set, LED magnifier, two counterweights, three O-rings, 3D sample holder |
| Brand | NYX |
|---|---|
| Model | HY-759-1 |
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Instrument Type | Crockmeter (Tribological Tester for Color Fastness) |
| Sample Size | 120 × 20 mm |
| Wool Felt Pad Area | 15 × 15 mm |
| Rubbing Hammer Mass | 500 g |
| Auxiliary Weight Mass | 500 g |
| Rubbing Speed | 40 ± 2 cycles/min |
| Stroke Length | 35 cm |
| Counter Range | 0–999,999 |
| Power Supply | AC 220 V, 50 Hz, 500 W |
| Operating Environment | 20 ± 2 °C, 65 ± 4 % RH |
| Dimensions (L×W×H) | 30 × 45 × 48 cm |
| Net Weight | 35 kg |
| Compliance Standards | QB/T 2537–2001, ISO 11640:2016, QB/T 2882–2007 (Method A), QB/T 2880–2007, GB/T 3903.31–2022, IUP 450, BS 1006:D02, DIN 53339, SATRA TM 173, SATRA TM 177 |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Model | SRV®5 |
| Instrument Type | Reciprocating Tribometer |
| Maximum Friction Force | 2500 N |
| Friction Force Resolution | 1 N |
| Operating Temperature Range | −35 °C to 1000 °C |
| Motion Modes | Reciprocating, Rotational, Tilted (0°–90°), Oscillatory, Non-Continuous Transition |
| Optional Modules | FSA (Friction Signal Analysis), Vacuum Chamber (High Vacuum), Nanopositioning Stage, Electrical Resistance Monitoring, Custom Fixture Integration |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | HPR |
| Instrument Type | Reciprocating Tribological Tester |
| Maximum Friction Force | 1–10 N |
| Temperature Range | Ambient to 130 °C |
| Load Range | 1–10 N |
| Contact Pressure | 0–1.4 GPa |
| Frequency Range | 10–200 Hz |
| Stroke Length | 20 µm–1.8 mm |
| Chamber Pressure Range | 10⁻⁵ torr to 10 bar |
| Sample Volume Capacity | 15 mL |
| Chamber Design | Fully Sealed, Removable & Pressure/Vacuum-Retentive |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MTM-EC |
| Instrument Type | Multi-Functional Tribological Tester |
| Maximum Friction Force | 75 N |
| Temperature Range | Ambient to 150 °C |
| Contact Pressure Range | 0–1.25 GPa (standard), up to 3.1 GPa (optional) |
| Sliding Speed | −4 to +4 m/s |
| Electrochemical Potential Range | ±60 V (high range), ±10 V (low range) |
| Current Range | 0–3.5 A (high), 0–200 mA (low) |
| Measurement Noise | ±120 mV / ±20 mA (high), ±20 mV / ±0.4 mA (low) |
| Sample Volume | 30 mL (10 mL with optional filler kit) |
| Dimensions (H×W×D) | 400 × 400 × 600 mm |
| Weight | 30 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM240-D |
| Motor Power | 0.75 kW |
| Supply Voltage | 380 V, 50 Hz (220 V optional) |
| Platen Speed | 75 ± 5 rpm |
| Load Options | 43 kg, 64 kg, 100 kg |
| Digital Counter Range | 0–9999 cycles |
| Dimensions (L×W×H) | 580 × 360 × 480 mm |
| Net Weight | 80 kg |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JDF05 |
| Instrument Type | Coefficient of Friction Tester |
| Max. Friction Force | Not Specified |
| Friction Force Resolution | mN |
| Compliance | ASTM D1894, ISO 8295, GB/T 10006 |
| Software Interface | USB + RS232 (COM port required) |
| Data Acquisition | Real-time force-time curve, static/dynamic COF calculation |
| Brand | PW (Yuelian) |
|---|---|
| Origin | Guangdong, China |
| Model | PW-1103F |
| Instrument Type | Coefficient of Friction (COF) Tester |
| Max Test Stroke | 6 in (150 mm) |
| Test Speed Range | 0–600 mm/min |
| Test Platform Dimensions | 5 in × 11 in (130 mm × 280 mm) |
| Load Cell Options | 10 N, 20 N |
| Power Supply | AC 220 V |
| Unit Weight | 20 kg |
| Footprint | 700 mm × 230 mm × 280 mm (W × H × D) |
| Compliance | ASTM D1894, GB/T 10006, ISO 8295 |
| Brand | Norman |
|---|---|
| Origin | USA |
| Model | 7-IBB |
| Compliance | ASTM F2357-04 |
| Abrasive Media | 11/16″ paper tape (1800 cycles/roll) or 1/4″ magnetic tape (3400 cycles/roll) |
| Load Options | 55 g, 175 g, 275 g |
| Cycle Counter Range | 0–9999 cycles |
| Import Status | Imported |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | M-200 |
| Instrument Type | Multi-Function Tribological Tester |
| Maximum Friction Force | 20 N |
| Friction Force Resolution | 0.4 mN |
| Maximum Operating Temperature | 45 °C |
| Maximum Test Load | 2000 N |
| Load Accuracy (≥10% FS) | ±2% |
| Load Repeatability (≥10% FS) | ≤2% |
| Friction Torque Range | 0–15 N·m |
| Torque Accuracy (≥10% FS) | ±3% |
| Torque Repeatability (≥10% FS) | ≤3% |
| Lower Specimen Shaft Speed | 200–400 rpm (stepless) |
| Upper Specimen Shaft Speed | 180/360 rpm |
| Axial Travel of Upper Specimen | ±4 mm |
| Time Control Range | 1 s – 9999 min |
| Revolution Count Range | 1 – 999999 |
| Specimen Dimensions | 30 mm × 7 mm × 6 mm |
| Counterface Ring | Ø40 × 10 mm, hardened 45# steel (HRC 40–45), surface roughness Ra ≤ 0.8 µm, concentricity < 0.01 mm |
| Normal Load Options | 196 N (±0.1%), extendable to 392 N |
| Standard Weights | One 4 kg + four 1 kg calibrated masses |
| Water Bath Integration | Yes |
| Power Supply | 120/230 V, 50/60 Hz, 2 A / 1 A |
| Dimensions (L×W×H) | 330 × 500 × 460 mm |
| Weight | 33 kg |
| Compliance Standards | ASTM D3514, D3885, D3886 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RJCS |
| Pricing | Available Upon Request |
| Motor | 60 W, 220 V, 50 Hz |
| Stroke Length | 120 ± 5 mm |
| Oscillation Frequency | 0–60 cycles/min |
| Applied Load | 1000 ± 10 g |
| Wiping Tip Contact Diameter | Ø14 ± 0.5 mm |
| Specimen Plate Size | 75 × 200 mm |
| Dimensions (L×W×H) | 260 × 260 × 340 mm |
| Net Weight | 17 kg |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | Brake-5000 |
| Instrument Type | Multifunctional Tribological Tester |
| Compliance | SAE J2522, ISO 6310, ASTM G99, ASTM D3702 |
| Drive Configuration | Dual-axis rotational (upper/lower spindle), high-torque motorized actuation |
| Data Acquisition | Real-time synchronized logging of normal load, friction torque, coefficient of friction (μ), sliding velocity, interface temperature, acoustic emission, wear depth, and volumetric wear loss |
| Control Modes | Programmable acceleration/deceleration profiles, constant-speed braking, step-load cycling, environmental conditioning (optional humidity/temperature chamber integration) |
| Software | Rtec Tribos™ v8.2 with GLP-compliant audit trail, FDA 21 CFR Part 11 user role management, and automated report generation per ISO/IEC 17025 requirements |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | FFT-1 |
| Instrument Type | Reciprocating Friction and Wear Tester |
| Maximum Normal Load (Fz) | Up to 5000 N |
| Maximum Test Temperature | 500 °C |
| Compliance | ISO 19291, ASTM E2789, ASTM D6425, ASTM D7421, ASTM D5707, ASTM D5706, ASTM D7594, DIN 51834-2/3/4 |
| Environmental Control | Integrated temperature chamber (−40 °C to 500 °C), optional humidity control |
| Sensor Integration | Displacement sensor, Acoustic Emission (AE) sensor, Contact Resistance sensor |
| Software | Real-time closed-loop control with customizable test scripting, statistical data reporting, GLP-compliant audit trail, FDA 21 CFR Part 11 ready configuration |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MBT-5000 |
| Instrument Type | Multifunctional Tribological Tester |
| Load Capacity | Up to 10 kN (customizable) |
| Motion Modes | Continuous Rotation & Oscillatory Motion |
| Temperature Control | Integrated Heating & Real-time Monitoring |
| Electrical Contact Resistance (ECR) Testing | Supported (programmable current/voltage) |
| Force Sensor | High-resolution capacitive tribometer |
| Software | Fully Integrated Control, Data Acquisition, and Analysis Suite with Logic-Based Test Termination |
| Compliance | Designed for ASTM D3702, ISO 20808, ISO 7148-1, and GLP/GMP-aligned data audit trails (21 CFR Part 11-ready configuration available) |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MFT-4000 |
| Instrument Type | Multi-Function Tribological Tester |
| Application Focus | Biomaterials Evaluation |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MFT-5000 |
| Maximum Friction Force | 3000 N |
| Friction Force Resolution | 0.1 mN |
| Maximum Temperature | 1200 °C |
| Load Range | 1 mN – 12,000 N |
| XY Stage Travel | X = 150 mm, Y = 210 mm |
| Positional Resolution | 0.1 µm (XY), 0.25 µm / 10 nm (Z) |
| Rotational Speed | 0.001 – 10,000 rpm |
| Reciprocating Frequency | up to 70 Hz |
| Stroke Range | 0.1 – 40 mm |
| Environmental Chamber Range | −120 °C to 1200 °C, 5–95% RH, vacuum down to 10⁻⁷ Torr, corrosive/atmospheric/gas/liquid/humidity/high-pressure options |
| In-situ 3D Topography | Confocal + White-Light Interferometry + Dark/Bright Field |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MFT-5000-EC |
| Instrument Type | Multifunctional Tribological Tester |
| Max Normal Load | 5000 N |
| Friction Force Resolution | 5 mN |
| Max Operating Temperature | 500 °C |
| Temperature Control Range | −25 to 150 °C |
| Humidity Control Range | 10–95 % RH |
| Reciprocating Frequency | 0.1–60 Hz |
| Reciprocating Stroke | up to 25 mm |
| Rotational Speed (CW) | 0.1–3000 rpm |
| Rotational Speed (CCW) | 0.001–100 rpm |
| Minimum Sliding Velocity | 0.1 µm/s |
| Electrochemical Configuration | Three-electrode system (working, counter, reference) |
| Liquid Circulation | Dynamic and passive |
| Environmental Chamber | Electrically insulated, splash-resistant |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MFT-5000-H |
| Maximum Normal Load | 12,000 N |
| Friction Force Resolution | 20 µN |
| Maximum Operating Temperature | 1200 °C |
| Motion Modes | Rotational & Reciprocating |
| Atmosphere Options | Inert Gas (N₂, Ar) |
| Thermal Drift Compensation | Active Cooling & Sensor Isolation |
| Compliance | ASTM G99, ISO 20808, ASTM D3702, ISO 7148-1 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MFT-5000-SST |
| Maximum Normal Load (Fz) | 5000 N |
| Friction Force Resolution | 5 µN |
| Maximum Operating Temperature | 150 °C |
| Environmental Chamber Compatibility | Salt Fog (ASTM B117, ISO 9227 compliant) |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MFT-EF |
| Type | Multifunctional Tribological Tester |
| Category | Import Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MPT-3000 |
| Maximum Friction Force | 8000 N |
| Friction Force Resolution | 0.15 N |
| Maximum Test Temperature | 150 °C |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | MVT-2 |
| Instrument Type | Multi-Functional Tribological Tester |
| Maximum Friction Force | 200 N |
| Friction Force Resolution | 0.25 µN |
| Temperature Range | −150 °C to +400 °C (with vacuum) |
| Environmental Control | High-Vacuum Compatible (≤10⁻⁶ mbar), Integrated Cryogenic Cooling & Anti-Condensation System |
| Load Control | Closed-Loop Servo-Driven, Programmable Constant/Linear Ramp Force |
| Motion Control | Precision Servo Motor, Adjustable Rotational/Linear Speed Profile |
| Data Acquisition | Multi-Channel, High-Speed (≥10 kHz), Low-Noise Controller |
| Software | Real-Time Control & Post-Processing Suite with ASTM/ISO Compliant Reporting Templates |
| Compliance | Supports GLP/GMP Audit Trail (21 CFR Part 11 Ready), ISO 20808, ASTM G99, ASTM D3702, ISO 7148-1 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | Slurry-Jet |
| Instrument Type | Multi-Functional Tribological Tester |
| Application Category | Erosion & Erosion-Corrosion Testing |
| Compliance Context | ASTM G73, ASTM G119, ISO 8501-1, ISO 12944-5 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | TM-2000 |
| Instrument Type | Multi-Function Tribological Tester |
| Speed Range | ±6 m/s |
| Contact Configuration | 19.05 mm steel ball vs. 46 mm steel disc |
| Control System | Closed-loop servo-driven |
| Temperature Control | Real-time, programmable |
| Data Output | Load, traction force, velocity, SRR, film thickness (optional module) |
| Compliance | ASTM D5001, ISO 12156-1, DIN 51834 (applicable modes) |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | TRT-1000 |
| Maximum Friction Force | 8000 N |
| Friction Force Resolution | 0.15 N |
| Maximum Test Temperature | 150 °C |
| Drive Type | Dual High-Torque Servo Motors |
| Force Actuation | Electromechanical Servo Loading |
| Environmental Control | Integrated Temperature Chamber (–20 °C to 150 °C) |
| Data Acquisition Rate | Up to 200 kHz |
| Compliance | ASTM D4170, ISO 6856, DIN 51819-1, EN 15380, GLP-Compatible Logging |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-628B1 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Oscillating/Reciprocating Tribological Tester |
| Max Friction Force | 0.5–25 N |
| Force Resolution | Not Specified |
| Max Operating Temperature | Ambient Only (No Heating Capability) |
| Cone Apex Angle | 166° |
| Oscillation Frequency | 75 cycles/min |
| Sample Holder Tilt Angle | 7° |
| Contact Load Range | 0.5–25 N (Adjustable) |
| Sample Area | 100 cm² |
| Effective Abrasion Area | 50 cm² |
| Dimensions (L×W×H) | 34 × 60 × 63 cm |
| Net Weight | 50 kg |
| Brand | TABER |
|---|---|
| Origin | USA |
| Model | 5135 |
| Instrument Type | Tribological Tester (Abrasion & Wear Tester) |
| Standard Weights | (2 × 500 g, 2 × 1000 g) |
| Abrasive Wheels | CS-10 (soft), H-18 (hard) |
| Sample Area | 30 cm² |
| Vacuum Dust Extraction | Integrated |
| Display | Digital LED |
| Control Interface | Front-panel membrane keys |
| Compliance | ASTM D4060, ISO 5470-1, TAPPI T476, DIN 53109, JIS K 5400, EN 530, SAE J2527 |
| Accessories Included | S-11 abrasive paper (100 sheets/pack), S-12 brush, S-16 specimen holder (4" square), vacuum hose & cleaning brush |
| Brand | TABER |
|---|---|
| Origin | USA |
| Model | 5155 |
| Type | Rotational Abrasion Tester |
| Standard Load Configuration | (2×500 g + 2×1000 g weights) |
| Abrasive Media Compatibility | S11 abrasive paper (100 sheets/pack), S12 bristle brush (extended handle), CS10 wheels (2 pairs, soft), H18 wheels (2 pairs, hard), S16 specimen holder (4" square) |
| Integrated Vacuum System | Includes cleaning brush and flexible hose |
| Compliance | ASTM D4060, ISO 5470-1, TAPPI T476, JIS K 7350 |