Used Instruments
Filter
Showing 181–210 of 645 results
| Brand | ASML |
|---|---|
| Origin | Netherlands |
| Model | TWINSCAN NXT:1980Di |
| Numerical Aperture (NA) | 1.35 |
| Minimum Achievable Resolution | ≤38 nm |
| Throughput | 275 wafers/hour (300 mm) |
| Process Node Support | 14 nm to 45 nm (with multi-patterning extending capability to ~7 nm) |
| Age | 3 years operational use |
| Condition | Fully refurbished and factory-recertified |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Azure 300 |
| Usage Duration | <1 year |
| Imaging Modalities | UV (254/302 nm), Blue Light (470 nm), White Light (LED transilluminator & reflected light), Chemiluminescence |
| Sensitivity | Sub-femtogram detection for HRP-based chemiluminescent substrates |
| Interface | Integrated 12.1″ capacitive touchscreen |
| Software | AzureSpot™ v6.x with FDA 21 CFR Part 11-compliant audit trail, GLP/GMP-ready workflow templates |
| Upgradability | Field-upgradable to Azure C400/C500/C600 platform architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported Analytical Instrument |
| Model | DU-64 |
| Spectral Range | 190–1100 nm |
| Optical Resolution | 1.0 nm (typical) |
| Photometric Accuracy | ±0.005 A (at 0.5 A, 546 nm) |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Detector | Silicon photodiode |
| Data Interface | RS-232 |
| Sample Compartment | Standard 10-mm cuvette holder |
| Software Compatibility | Beckman DU Series PC Software (DOS/Windows 3.1 legacy environment) |
| Operational Age | ~4 years |
| Warranty | 6 months limited hardware warranty |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P/ACE MDQ |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Capillary Electrophoresis Instrument |
| Operational Age | 3–4 years |
| Warranty | 6 months comprehensive |
| Included Components | Full system configuration (capillary cartridge, high-voltage power supply, UV-Vis detector, autosampler, CE control software, and validated startup kit) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UV-1601 / UV-1600 |
| Spectral Bandwidth Options | 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm |
| Detector | Imported Silicon Photodiode |
| Light Sources | Socket-type Imported Deuterium Lamp & Tungsten Halogen Lamp |
| Wavelength Range | 190–1100 nm (typical for class) |
| Power Supply | AC 220 V / 50 Hz or 110 V / 60 Hz |
| Power Consumption | 180 W |
| Dimensions (W×D×H) | 630 × 470 × 210 mm |
| Net Weight | 26 kg |
| Warranty | 6 months limited warranty |
| Condition | Refurbished — 90% operational life remaining, fully functional, factory-tested |
| Compliance | Designed to meet general requirements of ISO/IEC 17025 supporting laboratories |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WFX-120B |
| Price | USD 4,200 (FOB Beijing) |
| Product Category | Optical Spectroscopy |
| Operational Age | 6–8 years |
| Warranty | 6 months limited parts & labor |
| Instrument Type | Flame AAS |
| Flame Temperature Range | 2300–2950 °C (adjustable) |
| Wavelength Range | 190–900 nm |
| Grating Density | 1800 lines/mm |
| Focal Length | 277 mm |
| Blazed Wavelength | 250 nm |
| Spectral Bandwidth | Multi-step automatic switching |
| Atomizer | 10 cm single-slit titanium burner |
| Nebulizer | Metal-sheathed high-efficiency glass nebulizer |
| Sample Uptake Rate | 6–7 mL/min |
| Background Correction | D₂-lamp (≥30× at 1 Abs) and Self-Reversal (≥30× at 1.8 Abs) |
| Detector | Wide-spectral-range photomultiplier tube (PMT) |
| Lamp System | 6-position auto-switching turret (2 positions compatible with high-performance hollow cathode lamps) |
| Lamp Current Drive | 400 Hz square-wave pulse |
| Software Platform | Windows 98/Me/XP native BRAIC application suite |
| Data Output | RS-232 interface |
| Dimensions (W×D×H) | 1020 × 490 × 540 mm |
| Weight | 80 kg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-130B |
| Wavelength Range | 190–900 nm |
| Light Source | 4-lamp turret auto-switching (2 positions compatible with high-performance hollow cathode lamps) |
| Lamp Current Control | Wide-pulse 0–25 mA / Narrow-pulse 0–10 mA |
| Monochromator | Czerny-Turner type, 1800 lines/mm grating, 277 mm focal length, 250 nm blaze wavelength |
| Spectral Bandwidth | Multi-step automatic switching |
| Atomizer | 10 cm single-slit titanium burner, corrosion-resistant all-plastic nebulizer chamber, metal-sheathed high-efficiency glass nebulizer (6–7 mL/min uptake) |
| Background Correction | Deuterium lamp (≥30× correction at 1 Abs) and self-reversal (≥30× at 1.8 Abs) |
| Detector | High-sensitivity, broad-spectrum photomultiplier tube |
| Data System | Windows 98/Me/XP-compatible BRAIC software with automated calibration (standard addition, curve fitting), multi-element sequential analysis, statistical reporting (mean, SD, RSD), RS-232 interface |
| Dimensions & Weight | 1020 × 490 × 540 mm, 80 kg |
| Flame Temperature Range | 2300–2950 °C (oxygen-enriched air-acetylene system) |
| Operational Age | ≥7 years |
| Warranty | 6 months |
| Brand | Berghof |
|---|---|
| Origin | Germany |
| Model | easyH2O |
| Measurement Principle | Pyrolysis-Coulometric Titration (P₂O₅-based) |
| Temperature Range | Ambient to 400 °C |
| Max Heating Rate | 40 °C/min |
| Detection Limit | 1 μg H₂O |
| Repeatability | ≤2% (at max rated current) |
| Sample Water Content Range | 0.01–15 wt% |
| Display Resolution | ppm to 99.99% |
| Sample Volume | 3 cm³ |
| Power Supply | 220 V, 50 Hz, 400 W, 4 A fuse |
| Protection Class | IP1 |
| Dimensions (W×H×D) | 500×180×500 mm |
| Weight | ~20 kg |
| Carrier Gas | Built-in air pump (ambient air) |
| Compliance | CE, EN 61326-1, EN 61326-2, EN 61010 |
| Interface | RS-232 for balance & PC |
| PC OS Requirement | Windows 7 |
| Accessories Included | Dell laptop, certified reference standards, ceramic coating kit, nickel boats, cleaning brush |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 450 GC |
| Product Category | Chromatography |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | 450-GC |
| Instrument Type | Gas Chromatograph |
| Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Includes GC mainframe, optional autosampler, chromatography workstation, and essential tubing/cabling |
| Compliance | Fully tested and validated per ISO/IEC 17025-aligned internal protocols |
| Software | STAR Chromatography Data System (CDS), GLP-compliant audit trail enabled |
| Temperature Range | Oven programmable from ambient +4 °C to 450 °C (7 ramps, 8 plateaus) |
| Detector Compatibility | FID, TCD, ECD, TSD (NPD), PFPD, ion trap MS, quadrupole MS, and MS/MS |
| Inlet Options | Up to three simultaneous inlets including 1079 PTV (5 injection modes), 1177 split/splitless, and 1041 packed column |
| Carrier Gas Control | Precision electronic pressure/flow control (EPC) with gas-saving mode |
| Column Oven | Rapid heating/cooling kinetics for cycle time reduction |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | 450-GC+300MS |
| Configuration | GC-MS/MS (Triple Quadrupole) |
| Instrument Condition | Refurbished & Fully Qualified Used System |
| Regulatory Compliance | Designed to meet ASTM D5845, EPA Method 8270/8260, and ISO 17025 laboratory requirements |
| Software Platform | Bruker Compass DataAnalysis 5.4+ with QuantAnalysis and TargetScreener modules |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 456 |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty Period | 6 months |
| Included Automation | CP-8400 Autosampler |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Avance 700 |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Product Category | Spectroscopy |
| Operational Age | 3–4 Years |
| Warranty | 6 Months Limited |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | GC456-SCION TQ |
| Configuration | Used, Refurbished & Fully Qualified Triple Quadrupole GC-MS/MS System |
| Compliance | Meets ASTM D5845, EPA Method 8270/8260, and ISO 17025-aligned operational readiness standards |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | o-Advance |
| Pressure Rating | 10,000 PSI |
| Flow Range | 1 nL/min – 50 µL/min |
| Flow Precision | <0.25% RSD at ≤8 µL/min |
| Detector Interface | USB-controlled modular architecture |
| System Type | Nanoflow/Capillary UHPLC |
| Usage Duration | 3–4 years |
| Warranty | 6 months |
| Compliance | Pre-calibrated for LC-MS coupling |
| Software Compatibility | HyStar & Compass CDS |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | SCION 456-GC |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | GC system with optional autosampler, Compass CDS software, and essential gas lines/tubing |
| Compliance | Fully tested and validated per ISO/IEC 17025-aligned internal protocols |
| Regulatory Readiness | Compatible with FDA 21 CFR Part 11-compliant data integrity workflows when deployed with validated software configuration |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sequenom MassARRAY |
| Product Category | MALDI-TOF Mass Spectrometer |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | Sequenom MassARRAY |
| Configuration | Includes MassARRAY Analyzer 4, SpectroCHIP Reader, Integrated Workstation PC, and Full Software Suite |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | COMBIPAL |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Product Category | Chromatography |
| Service Life | 2–3 Years |
| Warranty | 6 Months |
| Compatibility | GC & GC/MS Platforms |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cohesive/CTC Twin HTS PAL |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography Instrumentation |
| Operational Age | 5–7 years |
| Warranty | 6 months limited parts and labor |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | COMBI-xt PAL |
| Age | 3–4 years |
| Warranty | 6 months |
| Included Modules | Liquid Sampling, Headspace (HS), SPME, ITEX-2, SPDE, Thermal Desorption, FlowCell, Dilutor |
| Compatibility | Universal GC & GC-MS platforms (Agilent, Thermo, Shimadzu, PerkinElmer, etc.) |
| Positioning Accuracy | ±0.1 mm (XYZ linear motion) |
| Structural Design | Overhead gantry architecture |
| Regulatory Readiness | Compliant with GLP/GMP workflows |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTC-PAL |
| Condition | Refurbished (7+ Years Operational History) |
| Warranty | 6 Months |
| Product Category | LC-MS Front-End Automation System |
| Bench Footprint | ≤50 cm |
| Microplate Capacity | Up to 24 Plates |
| Sample Temperature Control | Yes |
| Compatibility | Universal Interface for Major LC-MS Platforms (Agilent, Thermo Fisher, Waters, Shimadzu) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTC-Pal |
| Price | USD 6,000 |
| Product Category | Other Analytical Automation Equipment |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Instrument Model | HTC-Pal |
| Service Life | 3 Years |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTS-Pal |
| Age | 3–4 Years |
| Warranty | 6 Months |
| Control Mechanism | XYZ Stepper-Motor-Driven Positioning (0.10 mm/step) |
| Compliance | IQ/OQ Documentation Available |
| Configuration | LC & LC-MS Compatible |
| Refurbishment Standard | SpectraLab Scientific Certified |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HTS |
| Age | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DX-120 |
| Instrument Age | >10 Years |
| Pump Flow Rate | 0.5–4.0 mL/min |
| Max Pump Pressure | 4000 psi (27.5 MPa) |
| Conductivity Detector Range | 0–1700 µS |
| Temperature Compensation | 1.5–1.9%/°C |
| Detector Cell Volume | 1.25 µL |
| Operating Temperature | 10–40°C |
| Dimensions (H×W×L) | 60 × 30 × 40 cm |
| Weight | ~40 kg |
| Power Input | 100 V/50 Hz, 115 V/60 Hz, or 220–240 V/50 Hz |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1000 |
| Pump Flow Range | 0.00–5.00 mL/min (0.01 mL/min increments) |
| Maximum Pressure | 5000 psi |
| Conductivity Detector Range | 0–15,000 µS |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Included Components | ICS-1000 Console, AS40 Autosampler |
| Compliance | Fully Tested & Certified per SpectraLab Scientific Pre-Delivery Protocol |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICS-1000 |
| Price | Negotiable (USD) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1100 |
| Instrument Type | Ion Chromatograph |
| Usage Duration | 4 years |
| Warranty | 6 months |
| Compliance | ASTM D4327, ISO 14911, USP <645>, EPA Methods 300.0/300.1 |
| Software | Chromeleon® 7.2.10 or later |
| Detection Principle | Suppressed Conductivity Detection with Electrolytic Regeneration |
| Pump Material | PEEK (pH 0–14 compatible) |
| Max Pressure | 35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min |
| Conductivity Detector Resolution | 0.00238 µS/cm |
| Data Interface | USB 2.0 |
| Column Oven Temp Range | 30–60 °C ±0.5 °C |
| Suppressor Types Supported | SRS®, AES®, MMS™ |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1500 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Column Heater Temp Range | Ambient +5 °C to 60 °C |
| Control Interface | Front-panel keypad and Chromeleon™ software |
| Compliance | ASTM D4327, ISO 10304-1, USP <645>, EPA Methods 300.0 & 317.1 |
| Software | Chromeleon 7.2.10 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-2000 |
| Pump Type | Dual-piston reciprocating, microprocessor-controlled fixed-stroke, variable-speed |
| Flow Rate Range | 0.05–5.0 mL/min (0.01 mL/min increments) |
| Max Pressure | 35 MPa (5000 psi) |
| Pressure Ripple | <1.0% |
| Flow Accuracy | ±0.1% |
| Flow Precision | <0.1% |
| Column Oven Temp Range | Ambient +5°C to 60°C (±1°C stability, ±2°C accuracy at 40°C) |
| EG Concentration Range | 0.1–100 mM |
| EG Flow Range | 0.1–3.0 mL/min |
| EG Max Pressure | 21 MPa (3000 psi) |
| Conductivity Detector | Digital signal processing, linear range 1% at 1 mS, resolution 0.00238 nS, detection range 0–15000 µS, cell volume <1 µL, temperature control range ambient +7°C to 55°C (stability ≤0.01°C) |
| Suppressor Power Supply | AESR (0–150 mA, 1 mA steps), SRS (0–500 mA, 1 mA steps) |
| Dimensions (H×W×D) | 56.1 × 22.4 × 53.3 cm |
| Weight | 24.5 kg |
| Power | 100–240 V AC, 47–63 Hz |
| Operating Environment | 4–40°C, 5–95% RH (non-condensing) |