Used Instruments
Filter
Showing 271–300 of 645 results
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | AT20 / AT200 / AT261 |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Calibration Status | Verified and Functionally Tested |
| Compliance | Meets ISO/IEC 17025 traceable verification standards (per SpectraLab Scientific in-house protocol) |
| Reconditioning Level | Refurbished to OEM functional specifications |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB3002 |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Price Range | USD 1,400–7,000 (FOB) |
| Compliance | ISO/IEC 17025-aligned calibration documentation available |
| Included Accessories | Draft shield, calibration weights (class E2), RS232 interface cable, user manual (English) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PM4800 |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Price Range | USD 1,400–7,000 (FOB) |
| Configuration | Fully Tested & Calibrated Unit with Original Accessories |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MT5 / MX5 |
| Age | 3–4 years |
| Warranty | 6 months |
| Compliance | CE, ISO/IEC 17025-compatible operation |
| Calibration | Factory-tested and verified per internal QA protocol |
| Configuration | Complete system with draft shield, calibration weights, power supply, and user documentation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DNA Engine Opticon 2 |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Category | Real-Time PCR Detection System |
| Operational Age | 3–4 Years |
| Warranty | 6 Months Limited Hardware Warranty |
| Instrument Dimensions | 47 cm (L) × 34 cm (W) × 60 cm (H) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GenePix 4000B |
| Warranty Period | 6 months |
| Usage Duration | 4 years |
| Resolution Range | 5–100 µm |
| Dual-Laser Excitation Wavelengths | 635 nm & 532 nm |
| Scan Time (10 µm, dual-channel) | ≤6.5 min |
| PMT Auto-Balance | Yes |
| Focus Adjustment | Motorized Z-axis with manual override |
| Optical Path | Non-confocal epifluorescence |
| Software Integration | GenePix Pro 7.x (included), Acuity (optional) |
| Compliance | ASTM E2535-21 (Microarray Scanner Performance Verification), ISO/IEC 17025 traceable calibration protocols |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | D205 |
| Condition | Refurbished (4–5 years operational history) |
| Warranty | 6 months |
| Product Category | UV-Vis Absorbance Detector for HPLC Systems |
| Compliance | Fully tested and calibrated per ISO/IEC 17025-aligned refurbishment protocol |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 1010 |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Product Category | Environmental & Water Quality Analyzer |
| Pricing Range | USD $1,200–$6,500 (FOB) |
| Compliance Status | Fully Recertified per O.I. Analytical Service Bulletin SB-1010-REV3 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1020A |
| Price Range | USD 6,800–13,600 |
| Product Type | TOC Analyzer |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | 1020A |
| Service Life | 3 years |
| Brand | OtO |
|---|---|
| Origin | Taiwan |
| Model | SW2860-050 |
| Wavelength Range | 900–1700 nm |
| Detector | 256-pixel InGaAs linear array |
| Cooling | Thermoelectric (TE) |
| Usage Duration | 2 years |
| Warranty | ≥3 years |
| Condition | Refurbished, Fully Tested |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 200 |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months limited parts and labor |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 200 |
| Instrument Type | Atomic Absorption Spectrometer (Flame & Graphite Furnace Capable) |
| Optical System | True Dual-Beam Stepped Optics with Solid-State Detector |
| Gas Control | Fully Automated Flame Gas Management with Integrated Safety Interlocks |
| Warranty | 6 Months Limited Hardware Warranty |
| Operational Age | 3–4 Years |
| Compliance | Designed to meet ASTM E1941, ISO 8288, and USP <731> requirements for elemental analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 200 / AAnalyst 400 |
| Optical System | Echelle grating double-beam monochromator |
| Wavelength Range | 190–900 nm |
| Spectral Bandpass | 0.15 nm (AAnalyst 200), 0.12 nm (AAnalyst 400) |
| Focal Length | 300 mm |
| Grating Size | 36 × 185 mm, 79 lines/mm |
| Detector | Segmented solid-state detector |
| Lamp Support | Dual power supply for hollow-cathode lamps (HCLs) and electrodeless discharge lamps (EDLs) |
| Safety | Full flame interlock system with gas flow, burner head, drain level, and flame monitoring |
| Operating Temperature | 15–35 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| Dimensions | 70 × 65 × 65 cm |
| Weight | 49 kg |
| Power | 100–230 V AC, ±10 %, 50/60 Hz, ≤300 VA |
| Refurbishment Age | 3–4 years |
| Warranty | 6 months |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AAnalyst 400 |
| Operational Age | 4–5 Years |
| Warranty | 6 Months |
| Configuration | Fully Refurbished with PC and AA Software |
| Compliance Status | Fully Tested and Certified per ASTM E1908-22 and ISO/IEC 17025 Calibration Protocols |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 600 |
| Instrument Type | Atomic Absorption Spectrometer |
| Age | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E2173, ISO/IEC 17025-compatible operation |
| Software | WinLab32 v3.52 with instrument control and data reporting modules |
| Lamp Compatibility | Hollow Cathode Lamps (HCLs) and Electrodeless Discharge Lamps (EDLs) |
| Atomization | Flame and Graphite Furnace (with optional GF-3000 upgrade path) |
| Detection Limit (Flame) | Sub-ppb for Cu |
| (GF) | Low-pg range for Cd/Pb |
| Optical System | Double-beam, monochromator with 0.1/0.2/0.5/1.0 nm slit widths |
| Wavelength Range | 190–900 nm |
| Data Output | CSV, XML, PDF reports compliant with GLP audit trails |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 800 |
| Wavelength Range | 189–900 nm |
| Detector | Array-type CCD with integrated low-noise CMOS charge amplifier |
| Slit Width & Height | Motorized automatic selection |
| Lamp Compatibility | Hollow Cathode Lamps (HCL) and Electrodeless Discharge Lamps (EDL) |
| Flame System | Titanium burner head, inert pre-mix chamber, adjustable nebulizer |
| Graphite Furnace | Integrated power supply, IR temperature monitoring with voltage and resistance compensation, STPF platform-coated graphite tubes |
| Sample Introduction | Direct suspension injection for flame and furnace modes |
| Hydride Generation Compatibility | Fully compatible with domestic HG systems (e.g., As, Sb, Se, Hg) |
| FIAS-GF Coupling | Supported for online preconcentration |
| Software | WinLab32 v3.50+ (peak area/height quantitation, lamp auto-identification, method automation) |
| Compliance | Designed to support GLP/GMP workflows |
| Warranty | 6 months limited hardware warranty |
| Operational Age | 4 years |
| Certification | Factory-tested and performance-verified by SpectraLab Scientific |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Altus HPLC A10 |
| Instrument Age | 4–5 years in service (7-year total design life) |
| Warranty | 6 months |
| Configuration | PDA Detector, Solvent & Sample Module, Column Module, LabSolutions-compatible PC, tubing and interconnects included |
| Compliance | Fully tested per ASTM E2653-22 (Standard Guide for Verification of HPLC Systems) |
| Software Environment | Compatible with Waters Empower 3 (via standard ASCII/CSV export) and PerkinElmer’s legacy Turbochrom software |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ARVO X3 |
| Condition | Factory-Refurbished |
| Configuration | Complete System with Onboard Software, Filter Wheels, and Standard Optical Modules |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S/SL |
| Product Category | Chromatography |
| Usage Duration | 4–5 Years |
| Warranty Period | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AutoSystem GC |
| Instrument Type | Gas Chromatograph |
| Year of Manufacture | ~2016–2018 (7-year-old unit) |
| Warranty | 6 months |
| Configuration | Capillary/Split-Splitless Inlet, Programmable Temperature Vaporizing (PTV) Inlet, Cold-On-Column Inlet, Packed Column Inlet, Autosampler, FID/PID/NPD/ECD/TCD/FPD Detectors |
| Compliance | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocol |
| Software | Turbochrom v6.3.2 (or later compatible version) |
| Delivery Status | Ready-to-ship, bench-tested and calibrated |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem ECD |
| Instrument Type | Gas Chromatograph |
| Detector Configuration | Dual Electron Capture Detector (ECD) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Designed to meet ASTM D5845, EPA Method 8081B/8270, and ISO 10380 requirements for trace halogenated compound analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC with NPD & FID |
| Detector Types | Nitrogen-Phosphorus Detector (NPD), Flame Ionization Detector (FID) |
| Instrument Category | Gas Chromatograph (GC) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original PerkinElmer factory specifications for GC operation and detector performance |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem TCD |
| Instrument Category | Gas Chromatograph |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Automation | Integrated Autosampler |
| Condition | Refurbished & Fully Tested |
| Operational Age | >7 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D1945, ISO 6974, and USP <621> gas chromatography requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC |
| Detector Configuration | Dual FID |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 15528, and USP <621> for hydrocarbon and volatile organic compound analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Model 40 Headspace |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PID-ELCD |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty Period | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem XL |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Configuration | Refurbished, Fully Tested |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 6416, and USP <621> chromatographic system suitability requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Autosystem XL |
| Instrument Type | Gas Chromatograph |
| Year of Manufacture | ≥7 years old |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 10301, and USP <621> chromatographic system suitability requirements |
| Software Compatibility | Native support for TurboChrome v5.x and optional migration to Chromeleon CDS (via hardware interface adapter) |
| Detector Options Supported | FID, TCD, ECD, NPD, FPD, PID |
| Injector Types Supported | Split/splitless capillary inlet, programmable temperature vaporizing (PTV) inlet, cold-on-column (COC) inlet, packed column inlet |
| Automation | Compatible with PerkinElmer AS-100/AS-200 series autosamplers |
| Operating Environment | 15–35 °C, 20–80% RH non-condensing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 500 |
| Instrument Type | Gas Chromatograph |
| Age | 4 years |
| Warranty | 6 months |
| Detector Options | FID, ECD, TCD, NPD, FPD, PID |
| Injector Types | Capillary Split/Splitless, PTV, Cold On-Column, Packed Column |
| Automation | TurboMatrix Headspace Autosampler, TurboMatrix Thermal Desorber, Standard Liquid Autosampler |
| Software | TotalChrom™ or Chromeleon™ (version-dependent) |
| Operating Environment | Lab-grade controlled temperature and humidity |
| Compliance | Designed to support ASTM D3612, USP <467>, ISO 11843, EPA Methods 502.2, 524.2, 8240, 8260, and GLP/GMP data integrity requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | Clarus 500 |
| Instrument Type | Gas Chromatograph (GC) |
| Detector Configuration | FID & ECD |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 10301, and USP <621> for GC method execution |
