Water Quality Analysis
Filter
Showing 691–720 of 952 results
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTEA Micromac C |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China (Distributed) |
| Model | SYSTEA Micromac C |
| Measurement Principles | Colorimetric Spectrophotometry (UV-Vis) |
| Analytes | Nitrate-N, Nitrite-N, Ammonia-N, Orthophosphate, Silicate, Sulfate, Total Phosphorus, Total Nitrogen |
| Detection Method | Batch-type Flow-Through Cell with LED-based Photometric Detection |
| Operating Modes | Manual, Cyclic, Triggered, Continuous |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output |
| Optional | Ethernet interface, Pre-treatment module, Dual-waste separation (toxic/non-toxic), Leak detection sensor, Reagent level monitoring |
| Compliance Support | Designed for continuous unattended operation in GLP-aligned environmental monitoring labs |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Micromac C |
| Pricing | Available Upon Request |
| Brand | Micrometrix |
|---|---|
| Origin | USA |
| Model | SCM-1 |
| Measurement Range | −1000 to +1000 mV |
| Output | 4–20 mA, ±10 V, 0–10 V |
| Display | LED, millivolt resolution |
| Flow Rate | 1 L/min (standard), 5 GPM (optional) |
| Inlet/Outlet | 1/2″ barb inlet, 3/4″ barb outlet |
| Response Time | 1 second |
| Accuracy | ±0.1% of full scale |
| Enclosure | NEMA 4X, IP65 |
| Power | 230 VAC |
| Probe Materials | Delrin®, 316 stainless steel, PTFE |
| Sensor Serviceability | Replaceable piston, disposable PTFE sleeve, field-swappable electrodes |
| Communication | Modbus RTU (optional) |
| Alarm Outputs | Dual SPDT relays with adjustable setpoints |
| Zero & Sensitivity Adjustment | Front-panel accessible, continuous analog tuning |
| Diagnostic Indication | Flashing LED status indicator |
| Brand | Starwood |
|---|---|
| Model | ZLFI00001 |
| Membrane Diameter | 47 mm |
| Membrane Pore Size | 0.45 µm |
| Test Pressure | 2.0–2.2 bar (29–32 psi) |
| SDI Calculation Interval | 0–5–15 min |
| Compliance | ASTM D4189-95 |
| Includes | Pressure Regulator, 47 mm Filter Holder, ASTM-Compliant Mixed Cellulose Ester (MCE) Membranes |
| Accessories Required | 500 mL Graduated Cylinder (±5 mL graduation), Stopwatch (±0.2 s resolution) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Model | Aluminum Ion Detector |
| Type | Portable Multi-Ion Analyzer |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed for Field-Deployable Water Quality Monitoring per ISO 10523, ASTM D3590, and EPA Method 200.7 (ICP-OES reference correlation) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Quartz Crystal Microbalance (QCM) with Gold-Plated Fluoride-Specific Sensor Chip |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Regulatory Compliance | Designed for ISO 10523, ASTM D4192, and EPA Method 300.0–compatible workflows |
| Software Interface | USB-C–enabled embedded firmware with real-time data streaming and CSV export |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Endotoxin Detection System |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microfluidic Sensor Chip |
| Sensitivity | 0.00742 EU/mL |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed to support USP <85>, EP 2.6.14, and ISO 11737-1 workflows |
| Sample Format | Aqueous liquid samples only |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Interface | USB-C & Bluetooth 5.0 |
| Software Platform | MIPS EndoTrack™ v3.2 (Windows/macOS compatible) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Pesticide Detection System |
| Instrument Type | Multi-Ion Analyzer |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microsensor Chips |
| Sample Matrix | Aqueous Solutions |
| Configurations | Single-, Dual-, or Multi-Channel Options Available |
| Integrated Components | Micro-peristaltic Pumps, Multi-Functional Microfluidic Analysis Chamber, Embedded Signal Processing Unit |
| Brand | Macherey-Nagel (Germany) |
|---|---|
| Origin | Germany |
| Model | PF-3 919342 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Spectrophotometry |
| Wavelength | 365 nm |
| Measurement Range | 2–60,000 mg/L COD |
| Repeatability | High precision |
| Detection Limit | Low (optimized for high-sensitivity UV absorption) |
| Measurement Time | <5 seconds per sample |
| Sample Throughput | Single-sample mode |
| Optical System | LED-based photometer with interference filters (365/450/595 nm) |
| Wavelength Accuracy | ±2 nm |
| Bandwidth (FWHM) | 10–12 nm |
| Detector | Silicon photodiode |
| Cuvette Format | 16 mm round tubes |
| Data Storage | 50 measurement records |
| Display | Graphical LCD (64 × 128 pixels) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | 3×AA batteries (alkaline or rechargeable), USB bus power, optional internal rechargeable battery |
| Enclosure Rating | IP68 |
| Dimensions | 170 × 95 × 68 mm |
| Weight | 0.5 kg |
| Compliance | CE-marked |
| Warranty | 12 months |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | UV-140 |
| Measurement Principle | Single-Wavelength UV Absorption (254 nm or 280 nm) |
| Sensor Material | 1.4404 (316L Stainless Steel) |
| Window Material | Sapphire |
| Protection Rating | IP65 / NEMA 4X |
| Process Connections | DIN, ANSI, SMS, NPT, APV, TH |
| Pipe Size Range | DN25–DN125 (½″–5″) |
| Max. Process Pressure | 16 bar (PN16) / 150 psi (ANSI Class 150) |
| Max. Process Temperature | 90°C continuous, 140°C short-term |
| Cable Length | Up to 100 m |
| Detection System | Dual-Diode Photometric (Reference + Measurement at 254 nm or 280 nm) |
| Measurement Range | 0–2 AU (Absorbance Units) |
| Accuracy | ±2% of reading |
| Reproducibility | ±1% |
| Calibration Interval | 12 months |
| Optional Features | CIP-compatible cleaning jet probe, air purge (4 mm), Ex-zone I/II certification available |
| Compatible Transmitter | Messenger Series |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AS3 |
| Pricing | Available Upon Request |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek1 |
| Type | Online Analyzer |
| Application | Real-time turbidity and total suspended solids (TSS) measurement in liquid process streams |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±4% of reading |
| Resolution | 1 ppb |
| Detection Limit | 1 ppb |
| Repeatability | ≤3% RSD |
| Conductivity Range | 0.055–8.000 µS/cm |
| Sample Temp. | 1–95 °C |
| Ambient Temp. | 5–65 °C |
| Power | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Compliance | USP <643>, EP 2.2.44, FDA 21 CFR Part 11 (Audit Trail & User Authentication), GLP/GMP-ready |
| Brand | New Environmental Protection Industry in Qingdao |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | XY-600H |
| Instrument Type | Portable Volatile Phenol Analyzer |
| Detection Range | 0–12 mg/L |
| Detection Limit | 0.05 mg/L |
| Measurement Error | ≤±5% |
| Repeatability Error | ≤±3% |
| Wavelength Accuracy | ±1 nm |
| Optical Stability | ≤±0.001 A/20 min |
| Cuvette Type | Integrated Digestion–Colorimetric Tube |
| Wavelength Selection | Automatic by Parameter |
| Wavelength Calibration | Auto-calibration |
| Light Source | Dedicated Solid-state Cold Light Source |
| Displayed Data | Concentration, Transmittance (%), Absorbance (A) |
| Data Interface | USB |
| Printing | Built-in Thermal Printer |
| Data Storage | 100,000 Records, 120 Calibration Curves (including user-defined) |
| Display | 7-inch HD Color Touchscreen |
| Operating Environment | 5–45 °C, ≤50% RH (non-condensing) |
| Power Supply | DC 12 V / 2 A |
| AC Input | 100–240 V, 50–60 Hz |
| Dimensions | 350 × 220 × 130 mm |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | Ni-502 |
| Pricing | Available Upon Request |
| Measurement Principle | Absorption Photometry (UV-Vis, 540–560 nm) |
| Detection Range | High Range: 0.0–199.9 g/L Ni |
| Low Range | 0.00–19.99 g/L Ni |
| Resolution | 0.1 g/L (high), 0.01 g/L (low) |
| Accuracy | ±2% FS |
| Operating Temp. | 0–40 °C, ≤85% RH |
| Output | Isolated 4–20 mA DC (3-range switchable: 0–50/100/200 g/L or 0–5/10/20 g/L) |
| Relay Outputs | Two SPDT dry contacts (AC 200 V, 1 A resistive load) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Enclosure | IP65-rated panel-mount housing (96 × 96 × 163 mm, ~1.3 kg) |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA FIM FL |
| Camera Resolution | 12 MP |
| Magnification | 40× |
| Particle Detection Principle | Morphological Image Analysis |
| Measurable Size Range | 0.2 µm – 2 mm |
| Imaging Modes | Transmission Light (standard), Reflectance Light (optional) |
| Compliance | USP <788>, USP <789>, Ph. Eur. 2.9.19, ISO 21501-4, FDA 21 CFR Part 11 |
| Software | SMILLA View with Audit Trail, LIMS Integration, and GLP/GMP Workflow Support |
| Brand | OI Analytical |
|---|---|
| Origin | USA |
| Model | 1030S |
| Compatibility | Requires coupling with OI Analytical Aurora 1030W, 1030C, or 1030D TOC Analyzer |
| Sample Mass Range | 50 µg – 2 g |
| TC/TOC Quantification Range | 0.05 mg – 50 mg |
| Design | Vertical compact footprint |
| Gas Capture Method | Sealed sample bag system for post-combustion CO₂ retention and sequential analysis |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | OL1010 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Absorption Spectrophotometry (Based on ASTM D7066 & HJ 637–2012) |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Wavenumber Range | 3400–6000 cm⁻¹ |
| Absorbance Range | 0.0000–2.0000 AU |
| Sample Volume | 20–1000 mL (with OL-101 Auto-Sampler) |
| Extraction Ratio | Adjustable (0.01–100) |
| Analysis Time | <5 min (with OL-101 Auto-Sampler) |
| Repeatability | RSD <2% |
| Compliance | HJ 637–2012, HJ/T 91–2002, ASTM D7066, ISO 9377-2 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | OL 1011 |
| Instrument Type | Online |
| Measurement Principle | Infrared Spectrophotometry (ASTM D7066 / HJ 637–2012 compliant) |
| Measurement Range | Low Range: 0.01–10 mg/L |
| Medium Range | 0.1–1000 mg/L |
| High Range | 1–100,000 mg/L (with auto-dilution for over-range samples) |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Wavenumber Range | 3400–6000 cm⁻¹ |
| Absorbance Range | 0.0000–2.0000 AU |
| Repeatability | RSD < 2% |
| Sample Volume | 10–1000 mL |
| Extraction Ratio | Adjustable from 0.01× to 100× |
| Analysis Time | < 5 minutes per cycle |
| Calibration & Cleaning Intervals | User-configurable |
| Operating Temperature | 0–40 °C |
| Ambient Water Temperature Tolerance | 0–90 °C |
| Enclosure Rating | IP65 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 500 × 195 × 600 mm |
| Weight | 12 kg |
| Data Interface | MODBUS RTU (RS-485) or PROFIBUS DP |
| Control Options | Integrated touchscreen HMI or remote SCADA integration |
| Extraction Solvent | Carbon Tetrachloride (CCl₄) or Tetrachloroethylene (C₂Cl₄) |
| Adsorbent | Magnesium Silicate (for biogenic oil separation) |
| Solvent Recovery | Automated containment and collection system |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | OL 1020 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Infrared Absorption Spectrophotometry (ASTM D7066, HJ 637–2012) |
| Measurement Range | 0–50,000 mg/L (with automatic dilution for over-range samples) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Wavenumber Range | 3,400–6,000 cm⁻¹ |
| Absorbance Range | 0.0000–2.0000 AU |
| Sample Throughput | Up to 10 samples per batch |
| Sample Volume | 10–1,000 mL |
| Extraction Solvents | Tetrachloroethylene or Carbon Tetrachloride |
| Extraction Ratio Programmable | 0.01–100 |
| Measurement Time per Sample | <5 minutes |
| Compliance | HJ 637–2012, HJ/T 91–2002, ISO 9377-2:2000 (Water Quality — Determination of Hydrocarbon Oil Index) |
| Brand | Pannatek |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PANNATEK-WVOC |
| Price Range | USD 42,000 – 70,000 |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TrasION 1080 ICP-MS |
| Pricing | Available Upon Request |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PolyPen-Aqua |
| Instrument Type | Algal Counter |
| Light Source | Pulsed Xenon Lamp (380–780 nm) |
| Spectral Range | 380–780 nm |
| Measurement Modes | Reflectance, Absorbance, Transmittance |
| Data Output | Spectral curves (Aλ), derived pigment indices, GPS-tagged georeferenced records |
| Software Interface | PolyPen Control & Analysis Suite (Windows/macOS) |
| Compliance | Designed for field-deployable GLP-aligned workflows |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PONSEL |
| Price Range | USD 140–7,200 (FOB) |
| Detection Principle | Conductive Liquid-Level Sensing |
| Output Type | Non-polarized Dry Contact (SPST) |
| Detection Threshold | 0.5 mm water film |
| Detector Housing Material | PVC with Stainless Steel Electrodes |
| Electronics Enclosure Material | PVC |
| IP Rating | IP68 (Detector & Electronics Box) |
| Operating Temperature | 0–50 °C |
| Detector Dimensions (H×W×D) | 20 × 80 × 60.5 mm |
| Electronics Box Dimensions (H×D) | 120 × 40 mm |
| Detector-to-Box Cable Length | 9 m (fixed, shielded multi-strand polyurethane-sheathed cable) |
| Output Cables | Two 1 m polyurethane-sheathed leads with bare tinned-copper terminations |
| Power Supply | Internal Li-MnO₂ battery (3.6 V, 3-year typical service life) or external +3.6 V ±5% (SPN mode, <200 µA quiescent current) |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PSC |
| Instrument Type | Laboratory-Grade Automatic Precipitation Sampler |
| Sampling Height | 1.2 m |
| Collection Bucket Diameter | 30 cm |
| Power Consumption | 2 W (standby), 100 W (sampling) |
| Operating Temperature Range | −40 °C to +50 °C |
| Relative Humidity Tolerance | 100% RH |
| Wind Resistance | Up to Beaufort Scale 9 |
| Sensor Sensitivity | ≥0.05 mm/h |
| Housing Material | Stainless Steel Frame with Polyethylene Sampling Buckets |
| Net Weight | 50 kg |
| Internal Data Retention | Multi-year (non-volatile memory, no refresh required) |
| Communication Range | Up to 40 km via wireless telemetry |
| Rain Cover Closure Delay | User-configurable from 1–20 minutes post-precipitation |
| Integrated Rain Gauge | Yes (optional standard rain gauge compatible) |
| Refrigerated Sample Storage | Optional 1–5 °C cooling module available |
| Brand | PUREN |
|---|---|
| Model | PSC-I |
| Type | Laboratory-Grade Atmospheric Deposition Sampler |
| Sampling Height | 1.2 m |
| Bucket Diameter Options | 20 cm (Type A) or 30 cm (Type B) |
| Power Supply | AC 220 V, 50 Hz |
| Standby Power Consumption | 2 W |
| Operational Power Consumption | 100 W |
| Operating Temperature Range | −40 °C to +50 °C |
| Wind Resistance | Up to Beaufort Scale Level 9 |
| Relative Humidity Tolerance | 0–100 % RH |
| Sensor Sensitivity | ≥0.05 mm/h or ≥0.5 mm raindrop diameter |
| Closure Delay After Precipitation | Adjustable from 1 to 20 min |
| Enclosure Material | Stainless Steel Frame with Polyethylene Sampling Buckets |
| Weight | 30 kg (Type A), 50 kg (Type B) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PWAS-3000 |
| Pricing | Upon Request |
| Brand | Rannuo |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory-Based |
| Model | RN3006 |
| Measurement Principle | Fluorescence Spectrophotometry |
| Measurement Range | 0–10 mg/L |
| Detection Limit | 0.001 mg/L |
| Resolution | 0.0001 mg/L |
| Analysis Time per Sample | 5–8 minutes |
| Compliance Standard | GB 17378.4–2007 (Marine Monitoring Specifications – Part 4: Seawater Analysis) |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | RKFI Intelligent Unmanned Water Quality Laboratory |
| Price Range | USD 140,000 – 420,000 |