Water Quality Analysis
Filter
Showing 631–660 of 3694 results
| Brand | SAIL HERO (Geotech Series) |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Geotech Interface Meters |
| Instrument Type | Manual Bail-Down Interface Locator |
| Probe Diameter | 1.6 cm |
| Minimum Well ID | 19 mm (3/4″) |
| Power Supply | 9 V Alkaline Battery |
| Probe Material | Stainless Steel or PTFE-Coated |
| Cable | Stainless Steel Conductor with Viton® Stress-Relief Jacket |
| Measuring Tape | Steel Tape with Kynar® Coating |
| Frame | Anodized Aluminum |
| Reel Housing | Polypropylene |
| Carry Case | Waterproof-Lined Portable Bag with Rotating Spool Mount |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Laboratory Benchtop System |
| Model | TTs 4 CAR |
| Heating Positions | 4 |
| Distillation Flask Capacity | 800 mL |
| Max Heating Temperature | 650 °C |
| Programmable Methods | 99 |
| Magnetic Stirring | Integrated |
| Rated Power | 2000 W |
| Order No. | 12-06144 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAP 200 |
| Instrument Type | Laboratory Benchtop Distillation Unit |
| Water Consumption | ~5 L/min |
| Distillation Time | 2–4 min |
| Power Rating | 2200 W |
| Supply Frequency | 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Net Weight | 25 kg |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg sulfide |
| Recovery Rate | ≥99.5% |
| Power Supply | 230 V AC |
| Compliance | EN ISO 9001 certified manufacturing |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | VAPODEST 200 A |
| Instrument Type | Laboratory Benchtop Distillation System |
| Water Consumption | ~5 L/min |
| Distillation Time | 2–4 min |
| Power Rating | 2200 W |
| Frequency | 50/60 Hz |
| Weight | 25 kg |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Supply Voltage | 230 V AC |
| Recovery Rate | ≥99.5% |
| Quality Certification | Compliant with EN ISO 9001 throughout design, production, and shipment |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAPODEST 200 |
| Instrument Type | Benchtop Volatile Phenol Distillation Unit |
| Water Consumption | ~5 L/min |
| Distillation Time | 2–4 min |
| Power Rating | 2200 W |
| Voltage/Frequency | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 25 kg |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Recovery Rate | ≥99.5% |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Laboratory Benchtop Distillation Unit |
| Principle | Steam Distillation Coupled with Electrode-Based Ammonia Detection |
| Range | 0.1–200 mg NH₃-N per sample |
| Accuracy | ±1% of reading |
| LOD | 0.1 mg NH₃-N |
| Cycle Time | 2–4 min per sample |
| Throughput | 1 sample per run |
| Compliance | ISO 17025-ready, GLP/GMP-compatible architecture, FDA 21 CFR Part 11–enabled data integrity features |
| (English product name follows international B2B naming convention | origin + function + model + device type) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Total Calcium & Magnesium Hardness (as CaCO₃) |
| Measurement Principle | DPD-based Colorimetric Titration |
| Accuracy | ±5% of selected reagent range upper limit |
| Repeatability | ±2.5% of selected reagent range upper limit |
| Dimensions | 300 × 300 × 200 mm (H × W × D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Sample Temperature Range | 5–40 °C |
| Ambient Operating Temperature | 10–40 °C |
| Sample pH Range | 4–10 |
| Interferent Limits | Fe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm |
| Sample Pressure Range | 0.2–5 bar (recommended: 1–2 bar) |
| Measurement Cycle | Programmable interval (5–360 min), external trigger, or flow-pulse synchronized |
| Analysis Time | ~3 minutes (hardness-dependent) |
| Display | Graphical backlit LCD |
| Output Interfaces | 4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 0/4–20 mA analog output (750 Ω max), CAN bus interface |
| Digital Inputs | 2 programmable (IN1: analysis start / flow switch / pulse meter |
| IN2 | system reset) |
| Flushing Duration | Adjustable (15–1800 s) |
| Data Storage | SD card (event logs, fault records, measurement history) |
| Units | °dH, °f, ppm CaCO₃, mmol/L, mg/L, mval/L, °e |
| Mounting | Wall-mounted |
| Brand | Global Water |
|---|---|
| Origin | Germany (Manufactured under Global Water USA specification) |
| Model | FP111, FP211, FP311 |
| Measurement Principle | Electromagnetic pulse generation via turbine–propeller sensor with positive displacement hydrodynamic sampling |
| Velocity Range | 0.1–6.1 m/s |
| Accuracy | ±0.03 m/s |
| Display | Backlit LCD with anti-glare & UV-stabilized coating |
| Data Storage | 30 sets of min/max/average values |
| Operating Temperature | –20 °C to +70 °C |
| Storage Temperature | –30 °C to +80 °C |
| Probe Material | PVC housing, anodized aluminum shaft, stainless steel water bearings |
| Handle Length (extendable) | FP111: 1.1–1.8 m |
| FP211 | 1.7–4.6 m |
| FP311 | 0.76–1.7 m |
| Weight | FP111: 0.9 kg |
| FP211 | 1.4 kg |
| FP311 | 1.3 kg |
| Power | Sealed lithium battery, ~5-year typical service life, non-replaceable |
| Certifications | CE compliant |
| Optional Accessories | Rotatable probe head (±90°), alignment vanes for directional correction |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DPD |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | GR1500 |
| Quotation | Upon Request |
| Instrument Type | Online |
| Measurement Principle | Laser Light Absorption / Obstruction |
| Particle Size Range | 1.5–400 µm |
| Number of Adjustable Channels | 8 |
| Sensitivity | 1.5 µm |
| Resolution | ≤9% @2 µm |
| Signal-to-Noise Ratio | 3:1 |
| Detection Efficiency | ≥50% @1 µm |
| Max. Particle Concentration | 18,000 counts/mL |
| Counting Loss Rate | 10% at max. concentration |
| Flow Accuracy | ≤2% |
| Light Source | Laser Diode |
| Sample Flow Rate | 60 mL/min |
| Flow Control | Overflow Tube + Hydraulic Pressure Regulation |
| Cleaning Mode | Semi-Automatic |
| Sensor MTBF | 60,000–80,000 hours |
| Communication Interfaces | RS-485 (4-wire), Modbus RTU, 4–20 mA (optional) |
| Baud Rate | 9600 bit/s |
| Display Capacity | Up to 9,999,999 cumulative counts |
| Data Output Modes | Cumulative or Segmented Values |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | GR1501 |
| Pricing | Upon Request |
| Instrument Type | Online |
| Brand | Guo Ruili Heng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GR5050 |
| Instrument Type | Portable |
| Biological Indicator | Bioluminescent Bacteria (Aliivibrio fischeri) |
| Storage Temperature Range | −10 °C to 50 °C |
| Operational Reagent Temperature Range | 5 °C to 45 °C |
| Time-to-Result | ≤15 minutes post sample preparation |
| Brand | Greencarey Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Laboratory-Grade COD Analyzer |
| Model | GL-200A |
| Detection Principle | Rapid Digestion Method (HJ/T 399–2007) |
| Wavelength Accuracy | ≤±0.001 Abs/20 min (Optical Source Lifetime: 100,000 hours) |
| Measurement Range | 0–15,000 mg/L (segmented) |
| Accuracy | ≤±5% (COD >50 mg/L) |
| Repeatability | ≤±3% |
| LOD | 5 mg/L |
| Digestion Temp/Time | 165 °C / 20 min |
| Total Cycle Time | 25 min/batch |
| Sample Throughput | 1 batch per 25 min |
| Chloride Interference Tolerance | up to 2,000 mg/L |
| Cuvette Format | 16 mm round digestion tube (no post-digestion transfer required) |
| Display | 4.3″ color TFT LCD |
| Data Output | USB flash drive export & built-in thermal printer |
| Optical System | Solid-state cold light source |
| Housing Material | ABS (chemical-resistant, heat-stable, impact-durable) |
| Power Supply | DC 12 V, 5 A |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Dimensions | 300 × 222 × 88 mm |
| Weight | ~2.8 kg |
| Compliance | HJ/T 399–2007 (COD), HJ 535–2009 (NH₃-N), GB/T 11893–1989 (TP), HJ 636–2012 (TN), and 18+ additional water quality parameters with standardized photometric methods |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer | GreenPrima Ltd. |
| Model | 8200I |
| Instrument Type | Online Ion Analyzer |
| Ion Measured | Chloride (Cl⁻) |
| Measurement Range | 0–30,000 mg/L |
| Detection Limit | 1 mg/L |
| Response Time | ≤5 seconds |
| Accuracy | ±3% of Full Scale |
| Temperature Range | 0–80 °C |
| Resolution | 0.01 mg/L |
| Sensor Material | PPS (Polyphenylsulfone) |
| Max Operating Pressure | 3.5 bar |
| Cable Length | 5 m |
| Enclosure Rating | IP65 |
| Display | Backlit Graphic LCD |
| Output | Dual Isolated 4–20 mA (≤500 Ω), RS485 Modbus RTU |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Dimensions (H×W×D) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualys is800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualys is800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Aqualysis 300 |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Colorimetric Method |
| Measured Parameters | Residual Chlorine, Total Chlorine |
| Measurement Range | 0.02–2 ppm (low range), 0.02–10 ppm (high range) |
| Accuracy | ±2% of full scale value |
| Repeatability | ±1% of full scale value |
| Limit of Detection | 0.02 ppm |
| Dimensions | 400 × 300 × 150 mm (H × W × D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Display | Touchscreen LCD with bilingual (English/Chinese) interface |
| Output Options | Two programmable relay outputs (max. 250 V, 4 A), one isolated 4–20 mA analog output (load ≤750 Ω), one RS485 Modbus RTU port |
| Input Options | Two digital inputs (IN1 for flow-triggered analysis/start command |
| Sample Temperature Range | 5–45 °C |
| Ambient Operating Temperature | 0–45 °C |
| Sample Pressure Range | 0.2–5 bar (recommended: 1–2 bar) |
| Analysis Cycle Interval | User-configurable |
| Flush Duration | Programmable |
| Data Storage | Internal USB logging with event/fault history |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Measurement Method | Titration-based colorimetry |
| Measurement Time | 2–8 minutes (hardness-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Protection Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H × W × D) |
| Weight | 4 kg |
| Display | Color LCD |
| Units | °dH, °f, ppm CaCO₃, mmol/L |
| Outputs | 4 programmable relay outputs (max. 250 V, 4 A) |
| Inputs | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Measurement Modes | Continuous or interval (1–360 min) |
| Data Logging | Onboard storage with fault event recording |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium & Magnesium Hardness (as CaCO₃) |
| Measurement Method | Photometric Titration (Colorimetric Endpoint Detection) |
| Range | 0.447–625.8 ppm CaCO₃ |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Cycle Time | ~3 min (hardness-dependent) |
| Display | Color LCD with bilingual (EN/CN) interface |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Output Interfaces | 4 programmable relay outputs (250 VAC, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 (Modbus RTU) |
| Input Interfaces | 2 digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Data Logging | Internal storage with timestamped records |
| Sample Requirements | pH 4–10 |
| Sample Temp. | 5–40 °C |
| Operating Ambient Temp. | 10–40 °C |
| Sample Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Calibration | Auto-zero and endpoint validation via dual-wavelength photometry |
| Compliance | Designed for GLP-compliant operation |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium & Magnesium Hardness (as CaCO₃) |
| Measurement Principle | Photometric Titration (Colorimetric Endpoint Detection) |
| Measurement Range | 0.447–625.8 ppm CaCO₃ (configurable via reagent kits TH7001–TH7100) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Cycle Time | ~3 minutes (hardness-dependent) |
| Display | Color LCD with bilingual (English/Chinese) UI |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Output Interfaces | 4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 4–20 mA analog output (750 Ω max), 1 RS485 Modbus RTU port |
| Digital Inputs | 2 programmable (IN1: start analysis |
| IN2 | stop analysis) |
| Data Logging | Internal storage for time-stamped measurement records |
| Sample Requirements | pH 4–10 |
| Sample Temp. | 5–40 °C |
| Ambient Temp. | 10–40 °C |
| Operating Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Calibration & Maintenance | Factory-calibrated |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800 |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Measurement Method | Photometric Titration (Colorimetric Endpoint Detection) |
| Measurement Range | 0.447–625.8 ppm as CaCO₃ |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Cycle Time | ~3 minutes (hardness-dependent) |
| Display | Color LCD (Bilingual: English & Chinese) |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Output Interfaces | 4 programmable relay outputs (250 VAC / 4 A max), 1 isolated 4–20 mA analog output (750 Ω max), 1 RS485 (Modbus RTU) |
| Digital Inputs | 2 programmable (IN1: start analysis |
| IN2 | stop analysis) |
| Data Storage | Internal logging with timestamped records |
| Sample Requirements | pH 4–10 |
| Sample Temperature | 5–40 °C |
| Ambient Operating Temperature | 10–40 °C |
| Sample Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Calibration & Maintenance | Factory-calibrated |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium & Magnesium Hardness (as CaCO₃) |
| Measurement Method | Titrimetric Colorimetry |
| Measurement Range | 0.447–625.8 ppm CaCO₃ |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Cycle Time | ~3 minutes (hardness-dependent) |
| Display | Color LCD (bilingual: English/Chinese) |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Output Interfaces | 4 programmable relay outputs (250 VAC, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 |
| Digital Inputs | 2 programmable (IN1: start analysis |
| IN2 | stop analysis) |
| Data Storage | Internal logging |
| Sample Requirements | pH 4–10 |
| Sample Temp. | 5–40 °C |
| Ambient Temp. | 10–40 °C |
| Operating Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Compatible Reagents | TH7001, TH7003, TH7005, TH7010, TH7030, TH7050, TH7100 |
| Optional Multi-Channel Expansion | MCS series distributor (2–8 channels) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Aqualysis 800 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | TH7001 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Measurement Principle | Automated Colorimetric Titration |
| Measurement Range (with TH7001 reagent) | 0.447–625.8 ppm CaCO₃ |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Analysis Time | ~3 minutes (hardness-dependent) |
| Display | Color LCD with bilingual (English/Chinese) interface |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Output Interfaces | 4 programmable relay outputs (250 VAC, 4 A), 1 isolated 4–20 mA output (max. 750 Ω), 1 RS485 Modbus RTU port |
| Digital Inputs | 2 programmable (IN1: start analysis |
| IN2 | stop analysis) |
| Data Storage | Internal non-volatile memory for measurement logs and events |
| Sample Requirements | pH 4–10 |
| Sample Temp. | 5–40 °C |
| Operating Ambient Temp. | 10–40 °C |
| Sample Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Flush Time Programmable | 15–1800 s |
| Measurement Interval Programmable | 0–360 min |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Calcium & Magnesium Hardness (as CaCO₃), Total Alkalinity |
| Measurement Method | Photometric Titration (Colorimetric Endpoint Detection) |
| Measurement Time | ~3 min |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Range | 0.447–625.8 ppm as CaCO₃ |
| Display | Color LCD (Bilingual: English/Chinese) |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Output Interfaces | 4 programmable relay outputs (250 VAC / 4 A max), 1 × 4–20 mA (750 Ω max), 1 × RS485 (Modbus RTU) |
| Digital Inputs | 2 programmable (IN1: start analysis |
| IN2 | stop analysis) |
| Sample Temperature | 5–40 °C |
| Ambient Temperature | 10–40 °C |
| Sample Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Sample pH Range | 4–10 |
| Interference Limits | Fe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm |
| Measurement Interval | 0–360 min (user-configurable) |
| Rinse Duration | 15–1800 s (adjustable) |
| Compatible Reagents | TH7001/TH7003/TH7005/TH7010/TH7030/TH7050/TH7100 (hardness) |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Measurement Method | Titrimetric Colorimetry (Photometric Endpoint Detection) |
| Measurement Range | 0.447–625.8 ppm as CaCO₃ (configurable via reagent kits TH7001–TH7100) |
| Accuracy | ±2% of selected reagent’s upper limit |
| Repeatability | ±1% of selected reagent’s upper limit |
| Cycle Time | ~3 minutes (hardness-dependent) |
| Display | Color LCD with bilingual (English/Chinese) interface |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Outputs | 4 programmable relay contacts (250 VAC, 4 A), 1 isolated 4–20 mA analog output (max. 750 Ω), 1 RS485 Modbus RTU port |
| Inputs | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Data Logging | Internal storage for time-stamped measurement records |
| Sample Requirements | pH 4–10 |
| Sample Temp. | 5–40 °C |
| Operating Ambient Temp. | 10–40 °C |
| Sample Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800 |
| Price | Upon Request |
| Measurement Method | Titration-based colorimetry |
| Measurement Time | 2–8 minutes (hardness-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Protection Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H × W × D) |
| Weight | 4 kg |
| Display | Color LCD |
| Units | °dH, °f, ppm CaCO₃, mmol/L |
| Outputs | 4 programmable relay outputs (max. 250 V, 4 A) |
| Inputs | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Mode | Continuous or interval (1–360 min) |
| Calibration | Automatic |
| Diagnostics | Built-in self-diagnostic routines |
| Data Logging | Internal event and fault logging |
| Enclosure Design | Compact benchtop/integrated panel-mount housing |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Aqualysis 800A |
| Pricing | Available upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Price | Upon Request |
