Water Quality Analysis
Filter
Showing 721–750 of 948 results
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AT-H300 |
| Instrument Type | Laboratory |
| Measurement Principle | Infrared Spectrophotometry (Fourier-transform-free, dual-beam fixed-wavelength absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹) |
| Measurement Range | 0.01–64,000 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±0.01 mg/L |
| Resolution | 0.004 mg/L |
| Sample Throughput | 7–10 minutes per sample |
| Compliance | HJ 637–2018, HJ 1051–2019, HJ 1077–2019, JJG 1153–2023 |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AT-Z300 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | Ultraviolet Spectrophotometry (UV-Vis) |
| Measurement Range | 0.002–64,000 mg/L |
| Limit of Detection (LOD) | < 0.01 mg/L |
| Accuracy | ±0.2 mg/L |
| Resolution | < 0.004 mg/L |
| Analysis Time per Sample | 7–12 minutes |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Oxidation–Spectrophotometric Method |
| Measurement Range | 0–3500 mg/L COD<sub>Cr</sub> (expandable) |
| Repeatability | ±3% RSD |
| Limit of Detection | 5 mg/L COD<sub>Cr</sub> |
| Analysis Cycle Time | 60–360 min per measurement |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP523-01 |
| Instrument Type | Benchtop |
| Measurement Range | pH: −2.000–19.999 |
| Ion Concentration | 0.00–14.00 pX (equivalent to 0.01 mg/L–1000 mg/L depending on ion valence and selectivity) |
| Temperature | −10–110 °C |
| Detection Limit | 0.01 mg/L (typical for monovalent ions) |
| Response Time | ≤60 s (for ion concentration stabilization) |
| Accuracy | pH: ±0.002 pH |
| Ion | ±0.5% of reading (monovalent), ±1.0% of reading (divalent) |
| Temperature | ±0.4 °C |
| Temperature Compensation | Automatic, 0–100 °C (pH), 0–60 °C (ion) |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture with audit-trail-capable data logging |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YD300 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurement Principle | Spectrophotometric Method (Colorimetric Determination via Calcium/Magnesium Complex Formation) |
| Measured Parameter | Total Calcium and Magnesium Ion Concentration (as Total Hardness) |
| Measurement Range | 0–10 mmol/L (as CaCO₃ equivalent) |
| Repeatability | ≤ ±5% FS |
| IP Rating | IP67 |
| Display | Backlit LCD with Blue Illumination |
| Temperature Compensation | Automatic, 5–50 °C |
| Temperature Range | 0–60.0 °C (±0.5 °C accuracy) |
| Resolution | 0.01 / 0.1 unit (user-selectable per hardness scale) |
| Units Supported | mmol/L, mg/L (CaCO₃), mg/L (CaO), mmol/L (Boiler), mg/L (Ca), °fH (French), °dH (German), °eH (English) |
| Calibration Solutions | B1, B2, B3 standard kits included |
| Power | Battery-operated (low-voltage indicator) |
| Auto Functions | Auto-calibration, auto-zero, auto-hold, auto-shutdown, real-time temperature compensation |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-6A |
| Price Range | USD 7,000–10,000 (FOB) |
| Instrument Type | Laboratory Benchtop System |
| Sample Capacity | 6 positions |
| Flow Control | Motor-driven digital mass flow control (not manual rotameter) |
| Acid Addition | Programmable per-sample automated reagent injection |
| Operation Mode | Fully automated sequence-controlled workflow |
| Enclosure | Sealed vapor-tight chamber |
| Heating Method | Integrated water bath with PID temperature regulation |
| Interface | 7-inch capacitive touchscreen HMI |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MODEL 9001 |
| Application | Real-time in-situ chlorophyll a monitoring in surface water bodies |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MODEL 9880 |
| Instrument Type | Online Analyzer |
| Biological Sensing Element | Electroactive Bacteria (Exoelectrogens) |
| Repeatability | ±30% |
| Detection Principle | Microbial Fuel Cell (MFC)-Based Current Response to Toxic/Nutrient Perturbations |
| Communication Interfaces | RS485, Modbus TCP, 4–20 mA Output, Optional 3G/4G LTE |
| Display Interface | Chinese-Language Touchscreen HMI |
| Compliance Framework | Designed for ISO 11348-3 and ASTM D5664 alignment in operational context |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BM-6000 |
| Instrument Type | Online Analyzer |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Temperature Control Accuracy | ≤ ±1 °C |
| Batch Capacity | 10 samples per cycle |
| Measurement Time | 5 min (default assay duration) |
| Measurement Principle | Dual-optical-path bioluminescence inhibition assay |
| Compliance Standard | ISO 11348-3:2007 & GB/T 15441–1995 |
| Photometric Range | 0–200% relative light units (RLU) |
| Reproducibility (CV) | ≤10% |
| Pure Water Light Loss | ±3% |
| Sample Injection Precision | ≤2% (syringe-based volumetric delivery) |
| Data Storage | ≥2 years at 1-hour measurement interval |
| Communication Interface | RS-232 / RS-485 (Modbus RTU protocol) |
| Analog Output | 4–20 mA DC (≤300 Ω load) |
| Display | 12.1″ capacitive touchscreen LCD |
| Dimensions (W×D×H) | 560 × 430 × 1600 mm |
| Weight | ~20 kg |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DP8600 |
| Measurement Principle | Full-Spectrum Absorption Spectrophotometry |
| Wavelength Range | 190–1100 nm |
| Measurable Parameters | COD, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Nitrogen, Total Nitrogen, Total Phosphorus |
| Sample Holders | Cuvette (standard), 16 mm and 25 mm test tubes |
| Light Sources | Imported Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Detector | Imported Photodiode Array |
| Display | 7-inch TFT color touchscreen (bilingual: English/Chinese) |
| Optical Functions | Photometric Mode, Quantitative Analysis, Standard Curve Construction, Kinetic Scanning, Full-Spectrum Scan |
| Data Storage | USB flash drive support |
| Custom Curve Capability | Yes |
| Optional Accessories | 5 cm and 10 cm sample holders |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | MP5300 |
| Pricing | Available Upon Request |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SAI008 |
| Pricing | Upon Request |
| Measurement Principle | Hyperspectral Reflectance Analysis (400–1000 nm, 1 nm spectral resolution) |
| Measurable Parameters | COD, Ammonia-Nitrogen (NH₃-N), Total Phosphorus (TP), Total Nitrogen (TN), Chlorophyll-a, Turbidity, Secchi Depth, CODMn, Suspended Solids (SS), CDOM (optional), Attenuation Coefficient (optional) |
| Sampling Interval | Configurable down to 1 second |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SEN806C |
| Instrument Category | Manual Water Sampler |
| Instrument Type | Portable Water Sampler |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | UCA1000 |
| Instrument Type | Algal Monitoring and Control System |
| Compliance | HJ 915-2017, GB 3838-2002, GB/T 12519-2010 |
| Brand | SHDROID Scientific |
|---|---|
| Origin | Beijing, China |
| Model | CDOM-A01 |
| Detection Principle | Time-Resolved Fluorescence (TRF) with UV-LED Excitation & PMT-Based Single-Photon Counting |
| Measurement Output | CDOM Concentration (QSU or Raman-normalized units), Fluorescence Lifetime Distribution (ns range), Component-Specific Fluorescence Signatures |
| Environmental Rating | IP68 Submersible Housing (PTFE-Coated Aluminum Alloy) |
| Communication Interface | 100BASE-TX Ethernet (RJ45), Modbus TCP Support |
| Power Supply | 24 VDC ±10%, <8 W |
| Operating Temperature | −10 °C to +50 °C |
| Response Time | <5 s (real-time in-situ measurement) |
| Calibration Options | On-site NIST-traceable quinine sulfate & humic acid reference kits |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CY-2 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–1000 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ≤5% |
| Single-Sample Incubation Duration | 5 days |
| Repeatability | ±3% |
| Display | Direct-Reading Digital Display |
| Batch Capacity | 8 samples per run |
| Incubation Temperature Control | 20 ± 1 °C |
| Dimensions (W × D × H) | 400 × 270 × 350 mm |
| Net Weight | 6 kg |
| Power Consumption | <15 W |
| Compliance | GB 7488–1987 |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PMULP-800 |
| Instrument Type | Portable |
| Temperature Range | 0–100 °C |
| pH Range | 0.00–14.00 |
| Dissolved Oxygen (DO) Range | 0–20.0 mg/L |
| Conductivity Range | 0.00 µS/cm – 199.9 mS/cm |
| Turbidity Range | 0–400 NTU |
| Optical Wavelengths | 420, 440, 470, 520, 540, 560, 610, 630, 660, 680, 700 nm (user-selectable within range) |
| Absorbance Accuracy | ≤±5% FS |
| Repeatability | ≤3% RSD |
| Absorbance Drift | <0.002 A in 20 min |
| Dimensions (Main Unit) | 92 × 185 × 50 mm |
| Weight (Main Unit) | ~0.4 kg |
| Total Kit Weight (incl. case & accessories) | ~1.5 kg |
| Power Supply | Rechargeable Li-ion battery, 7.4 V / 1500 mAh |
| Operating Environment | 5–40 °C, ≤85% RH, low-vibration, non-direct-sunlight |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M926, M926S |
| Instrument Type | Benchtop Chloride Analyzer |
| Detection Principle | Coulometric Titration (Silver Nitrate Electrolytic Generation) |
| Sample Volume | M926: 500 µL |
| M926S | 20 µL |
| Measurement Range | M926: 10–999 mg/L Cl⁻ (equivalent to 2–165 mg% NaCl) |
| M926S | 10–299 mmol/L Cl⁻ |
| Detection Limit | 10 mg/L Cl⁻ (M926) |
| Response Time | ≤36 s (typical endpoint detection) |
| Accuracy | M926: ±3 mg/L or <1% RSD at 0.1% Cl⁻ |
| M926S | ±2% at 100 mmol/L Cl⁻ |
| Linearity | ≤1% deviation across full range |
| Repeatability (CV, n=20) | <1.5% at mid-range concentration |
| Temperature Control | Integrated ambient-temperature-stabilized cell compartment |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | COD-4200 |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Temperature Potassium Dichromate Digestion with Photometric Detection |
| Standard Range | 30–4000 mg/L COD |
| Accuracy | ±10% at ≥100 mg/L |
| Repeatability | ≤±5% |
| Zero Drift | ±5 mg/L |
| Span Drift | ≤±5% |
| Resolution | <1 mg/L |
| Minimum Measurement Cycle | 20 minutes |
| Calibration Modes | Manual and Automatic |
| Communication Interfaces | RS-232, 4–20 mA (bidirectional) |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Power Consumption | ~100 VA |
| Dimensions | 500 mm × 420 mm × 1550 mm |
| Weight | ~90 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | HMA-4200 Series |
| Measurement Principles | Colorimetric Spectrophotometry per ISO 11969 / GB/T 7467–1987 (for Cr(VI)), ISO 11045 / GB/T 7475–1987 (for Total Cr, Cu, Ni) |
| Detection Range | 0–2 mg/L (Cr(VI), Total Cr), 0–3.5 mg/L (Total Cu), 0–10 mg/L (Total Ni) |
| Accuracy | ≤±5% FS |
| Repeatability | ≤±5% RSD |
| Linearity Error | ≤±5% FS |
| Span Drift | ≤±5% over 24 h |
| Zero Drift | ≤±3% (Cr(VI), Total Ni), ≤±5% (Total Cu) |
| Minimum Measurement Cycle | 20 min (Cr(VI)), 50 min (Total Cr, Cu, Ni) |
| Calibration Mode | Manual or Automatic (with standard solution dispensing module) |
| Output Interface | RS-232 serial port and isolated 4–20 mA analog output |
| MTBF | ≥1440 h |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions (H×W×D) | 1550 × 500 × 420 mm |
| Enclosure Rating | IP54 (indoor installation) |
| Compliance | Designed to support ISO/IEC 17025-compliant QA/QC workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TNP-4200 |
| Measurement Parameters | Total Nitrogen (TN), Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Alkaline Potassium Persulfate UV Oxidation – UV Absorbance (TN) |
| Detection Range | TN: 0–2 / 5 / 10 / 20 / 50 / 100 / 200 mg N/L |
| TP | 0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L |
| Cycle Time | 60 min (simultaneous TN & TP) |
| Power Consumption | ≤300 VA (AC 100–240 V, 50/60 Hz) |
| Operating Environment | Indoor use only |
| Sample Pretreatment | High-speed rotary homogenizer with auto backwash filter |
| Auto-Cleaning | Scheduled distilled water flush of fluidic pathways |
| Auto-Calibration | Dual-point (zero & span) using standard solutions |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TOC-4200 |
| Instrument Type | Online TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Detection Principle | NDIR (Non-Dispersive Infrared) CO₂ Detection |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (auto-ranging) |
| Cycle Time | Minimum 4 minutes per analysis |
| Carrier Gas | High-Purity Nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, Indoor Installation Only |
| Calibration | Auto-zero & span calibration |
| Sample Handling | Integrated high-speed rotary homogenizer |
| Internal Cleaning | Scheduled distilled-water flush of fluidic pathways |
| Interface | Full-color capacitive touchscreen |
| Communication | MODBUS RTU over RS-232/RS-485, 4–20 mA analog output, digital I/O |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TOC-L |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion Oxidation (680 °C) |
| Measurement Range | 4 μg/L to 30,000 mg/L |
| Detection Principle | CO₂ quantification via Non-Dispersive Infrared (NDIR) detection after catalytic combustion |
| Power Savings | Up to 36% vs. prior generation (8 h/day, 5 days/week) |
| Footprint Reduction | Width reduced from ~440 mm to 340 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | TP-4110 |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Persulfate UV Oxidation–Molybdenum Blue Spectrophotometry |
| Detection Range | 0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L |
| Measurement Cycle | 60 min |
| Sample Pretreatment | High-speed rotary homogenizer + automatic backwash filtration using tap water |
| Automatic Cleaning | Distilled water flush at user-defined intervals |
| Power Supply | 220 V ±10 V, 50/60 Hz, ≤300 VA |
| Operating Temperature | 1–40 °C |
| Relative Humidity | ≤90 % RH (non-condensing) |
| Installation | Indoor only |
| Compliance | Designed for continuous compliance monitoring per China’s HJ 353–2019, HJ 354–2019, and HJ 355–2019 standards for online water quality analyzers |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UVM-4020 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Weighted Multi-Wavelength Ultraviolet Absorption Spectrophotometry (243 nm, 254 nm, 265 nm, 275 nm, 290 nm) |
| Calibration | Automatic zero/span calibration with standard solutions (optional) |
| Measurement Ranges | 0–400 SAC, 0–200 SAC, 0–80 SAC |
| Cycle Time | 1 min (minimum), adjustable from 10 to 720 min |
| Output Parameters | COD, BOD, TOC, SAC |
| Preloaded Conversion Formulas | 30 built-in empirical equations |
| Auto-Cleaning Interval | User-configurable timer-based internal tubing flush |
| Power Supply | 220 V ±10 V, 50/60 Hz, ~100 VA |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing, non-freezing) |
| Sample Flow Rate | 1–2 L/min |
| Max. Sample Pressure | ≤50 kPa |
| Installation | Indoor only |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SIA-3000 Series |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP), Ammonia-Nitrogen (NH₃-N), Permanganate Index (CODₘₙ), Chemical Oxygen Demand (COD) |
| Regulatory Compliance | HJ 636, GB 11893, HJ 536, GB 11892, HJ 828 |
| Sample Matrix | Surface Water, Drinking Water, Municipal Wastewater, Industrial Process Water, Effluent from Pollution Sources |
| Measurement Modes | Continuous, Cyclic, Manual, Remote-Triggered |
| Calibration & Maintenance | Automated Cyclic Cleaning and Standard Calibration |
| Flow Architecture | Sequential Injection Analysis (SIA) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 500RL |
| Detection Range | 0.03–2,500 ppb as C |
| Accuracy | ±5% |
| Precision | ≤0.03 ppb (for <3 ppb) or ≤1% RSD (for ≥3 ppb) |
| Conductivity Measurement Range | 0.01–35 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm (≤0.25 µS/cm) or ±2% (>0.25 µS/cm) |
| Conductivity Precision | <0.25% RSD |
| Max Acceptable Sample Conductivity | 25 µS/cm at 25°C (neutral pH) |
| Ozone Tolerance | 200 ppb |
| Operating Temperature Range | 1–95°C (steam-tolerant for short durations) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 900 |
| Detection Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% |
| Precision | <1% RSD |
| Oxidation Method | UV/Persulfate |
| Detection Method | Membrane Conductivity |
| Sample Pressure | up to 250 psi |
| Flow Rate | 30–300 mL/min |
| Sample Temperature | 1–95 °C |
| Analysis Time | 4 min (standard), 4 s (rapid module) |
| IP Rating | IP65 |
| Compliance | US EPA Method 5310C, US EPA 415.3, ASTM D7573 |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CheckPoint |
| Pricing | Available Upon Request |
| Detection Range | 0.05–1,000 ppb C |
| Precision | Greater of <1% RSD or 0.05 ppb (online, 20–40 °C) |
| Analysis Modes | Online continuous averaging, online timed sampling, offline grab sampling |
| Analysis Time | 15 s (online), 10 min (grab) |
| TOC Calibration Interval | 6 months |
| Conductivity Tolerance | Up to 1.4 µS/cm (0.7 MΩ·cm) CO₂-compensated conductivity |
| Conductivity Precision | ±0.5% RSD (20–40 °C) |
| Conductivity Accuracy | ±2.0% |
| Conductivity Calibration Interval | 6 months |
| Operating Pressure (Online) | 15–100 psi |
| Low-Pressure Sampling | Max. 0.70 m head above analyzer |
| Minimum Online Flow Rate | >60 mL/min |
| Power Supply | 100–240 V ±10%, 60 W, 50/60 Hz |
| Sample Temperature Range | 10–90 °C |
| Ambient Operating Temperature | 10–40 °C |
| Enclosure Rating | Indoor use only |
| I/O Options | Ethernet, 2 analog outputs, 2 alarm outputs, parallel inputs |
| Installation Category | Overvoltage Category II |
| Dimensions (H×W×D) | 25.4 × 30.48 × 15.24 cm (standard) |
| Weight | 2.9 kg (no battery), 3.58 kg (with battery), +0.6 kg (vial sampler) |
| Safety Certifications | CE, ETL Listed |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx |
| Detection Range | 0.05–50,000 ppm TOC |
| LOD | 0.05 ppm TOC |
| Accuracy | ±3% at 50 mg/L NPOC |
| Precision | RSD <5% at 50 mg/L NPOC |
| Linearity | R² >0.995 |
| Analysis Time | 2.2–7.3 min |
| Calibration Stability | 6 months |
| Particle Tolerance | <800 µm |
| Operating Temp | 10–40 °C |
| Sample Temp | 10–60 °C |
| Humidity | ≤95% RH (non-condensing) |
| Power | 100–240 VAC ±10%, 400 W, 50/60 Hz |
| Dimensions | 52.05 × 32.26 × 58.42 cm |
| Weight | 22.4 kg |
| Interface | Ethernet + 3 USB ports |
| Display | Color touchscreen |