| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LH-C600 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | COD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Turbidity, Color, Suspended Solids, Heavy Metals, Organic & Inorganic Contaminants |
| Compliance Standards | HJ/T 399–2007 (COD), HJ 535–2009 (Ammonia Nitrogen), GB 11893–1989 (Total Phosphorus) |
| Operating System | LHOS (Android-based) |
| Light Sources | 8 LED sources (visible spectrum, fixed wavelengths) |
| Digestion Unit | Integrated dual-zone 12-position heater (6+6), supporting 16 mm / 25 mm tubes and 10 mm / 30 mm cuvettes |
| Power Supply | Rechargeable lithium battery (≥8 h continuous operation off-grid) |
| Connectivity | 4G, Wi-Fi, GNSS (BeiDou, GPS, GLONASS, Galileo) |
| Calibration | User-definable multi-point/single-point curve calibration with auto-log and recall |
| Customization | 20 user-defined test methods |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LH-C700 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurable Parameters | COD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Heavy Metals, Organic Matter, Inorganic Ions, pH, Dissolved Oxygen (DO), Electrical Conductivity (EC), Oxidation-Reduction Potential (ORP), Turbidity |
| Regulatory Compliance | HJ/T 399–2007 (COD), HJ 535–2009 (Ammonia Nitrogen), GB 11893–1989 (Total Phosphorus), HJ 506–2009 (Dissolved Oxygen) |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LH-E600 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Principle | Electrochemical Sensing (pH, DO, EC, ORP), Optical Absorption (COD, NH₃-N), Nephelometry (Turbidity), Fluorometry (Chlorophyll-a, Phycocyanin), Light Scattering (SS, Algal Density) |
| Measured Parameters | pH, Dissolved Oxygen (DO), Electrical Conductivity (EC), Salinity, Total Dissolved Solids (TDS), Oxidation-Reduction Potential (ORP), Turbidity, Chemical Oxygen Demand (COD), Ammonia Nitrogen (NH₃-N), Chlorophyll-a, Phycocyanin (Blue-Green Algae), Suspended Solids (SS) — 12 Parameters |
| pH Range | 0–14 |
| Default Cable Length | 5 m (customizable) |
| Display | 10-inch capacitive touchscreen integrated into carrying case lid |
| Data Storage | 22,720 entries per parameter |
| Power Supply | Rechargeable Li-ion battery + AC 220 V adapter (auto-switching) |
| Communication | USB, RS-485, 4G LTE dual-mode |
| Positioning | Dual-frequency GPS/BeiDou GNSS module |
| Optional | 720p HD camera for field documentation |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LH-JE113 |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Detection Principle | Colorimetric and Electrochemical Measurement (Standard Method Compliant) |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer | LoHua Technology Co., Ltd. |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Detection Principle | Spectrophotometry |
| Primary Application | Oil-in-Water Quantification |
| Compliance Context | Designed for routine compliance testing per ISO 7027, EPA Method 1664 (modified), and GB/T 16488–1996 |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LH-S760 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Methods | Photometry (Visible & UV), Electrochemical Analysis |
| Wavelength Range | 190–1100 nm |
| Electrode Support | 14 parameters |
| Photometric Parameters | >60 |
| Display | 10-inch HD capacitive touchscreen |
| Data Storage | ≥100,000 records (16 GB internal memory) |
| Input/Output | HDMI output, Wi-Fi, USB, optional printer support |
| Operating System | LHOS (Android-based) |
| Compliance | Designed for ISO 7027, ISO 8466-1, ASTM D1253, EPA 365.3, USP <643>, and GLP/GMP-aligned data integrity workflows |
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LH-S780 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Conductivity, Photometric Measurement, Quantitative Analysis, Kinetic Analysis, Wavelength Scanning, Multi-Wavelength Analysis, UV-Based Total Nitrogen, Electrochemical Measurement |
| Optical Range | 190–1100 nm |
| Display | 10-inch HD capacitive touchscreen (Android-based LHOS) |
| Data Storage | 16 GB internal memory (≥100,000 records) |
| Connectivity | Wi-Fi, IoT-enabled, HDMI output |
| Compliance | JJG-178–2007 Class II spectrophotometer specification |
| Electrode Interface | Digital IP68-rated electrodes with temperature compensation and independent calibration |
| Cuvette Compatibility | 1–4-position automated cuvette holder (1–5 cm pathlength), φ16 mm tube measurement |
| Light Sources | Replaceable tungsten and deuterium lamps (socket-mounted, no optical realignment required) |
| Brand | LoHua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | 5B-6C(V10) |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Measured Parameters | COD, Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP), Turbidity |
| Data Storage Capacity | 16,000 measurement records |
| Integrated Digestion Unit | Yes, with intelligent heating control, programmable timer, and thermal delay protection |
| Calibration Method | Built-in curve generation and storage using standard reference solutions |
| Output Interface | USB port + infrared data transmission |
| Printing Capability | Integrated thermal printer |
| Optical System | Multi-channel interference-free optical path supporting both cuvette and tube colorimetry |
| Housing | Patented injection-molded enclosure |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (PRC) |
| Model | LQ-5Z |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LQ-5Z-Multi |
| Pricing | Available Upon Request |
| Measurement Principle | Electrode-Based (Grab Sampling) |
| Measurement Range | TMAH: 0.00–5.0% / 0.0–50.0 g/L |
| NaOH | 0.00–3.00% / 0.0–30.0 g/L |
| Na₂CO₃ | 0.0–10.0% / 0–100 g/L |
| NH₃ | 0.0–2.00% / 0.0–20.0 g/L |
| H₂SO₄ | 0.0–2.00% / 0.0–20.0 g/L |
| HNO₃ | 0.0–2.00% / 0.0–20.0 g/L |
| Sample Temperature | 0.0–40.0 °C |
| Accuracy | ±5% FS |
| Calibration | Zero and Span Calibration |
| Temperature Compensation | Automatic |
| Enclosure Rating | IP66 |
| Power Supply | 3×AAA batteries with auto power-off |
| Electrode Type | 4C-type, 1 m standard cable |
| Dimensions (Instrument) | 75(W)×180(D)×38(H) mm |
| Electrode Dimensions | φ17×180(L) mm |
| Weight (Instrument) | ~300 g |
| Weight (Electrode) | ~50 g |
| Standard Kit | Analyzer with batteries, 4C electrode, user manual, certificate of conformity |
| Brand | Yoke (Shanghai Youke Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Benchtop Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Total Phosphorus (TP), Total Nitrogen (TN), Ammonia-Nitrogen (NH₃-N) |
| Measurement Principle | Spectrophotometric Analysis with Integrated Auto-Digestion |
| Display | 7-inch Capacitive Touchscreen |
| COD Range | 4–10,000 mg/L (segmented) |
| NH₃-N Range | 0–100 mg/L (segmented) |
| TN Range | 0–50 mg/L (segmented) |
| TP Range | 0–20 mg/L (segmented) |
| Compliance | GB/T 11914–1989, HJ 399–2007, HJ 535–2009, HJ 636–2012, HJ 670–2013 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | FLUORAT-02 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Methods | Fluorometry, Photometry, Chemiluminescence |
| Measured Parameters | Oil in Water, Volatile Phenols, Anionic Surfactants, COD, Turbidity, Cyanide, Uranium, Vanadium, Molybdenum, Nickel, Manganese, Chromium |
| Spectral Range | 250–900 nm |
| Cuvette Pathlengths | 10, 20, and 40 mm |
| Power Supply | 200–240 VAC, 50 Hz |
| Dimensions | 305 × 320 × 110 mm |
| Weight | 6.5 kg |
| Power Consumption | 36 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M90S |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principles | Photometric (Colorimetric), Ion-Selective Electrode (ISE), and Specialized High-Purity Water Analysis Modules |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | PF-12 Plus |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Principle | Colorimetric Method |
| Measurable Parameters | Ni, Cu, Cr, COD, Ammonia-N, Total Phosphorus, Total Nitrogen, Turbidity (1–1000 NTU), Residual Chlorine, and up to 60 parameters |
| Optical System | Single-beam filter photometer with 7-position filter wheel (345, 436, 470, 540, 585, 620, 690 nm) + optional 860 nm LED for turbidity |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10–12 nm |
| Photometric Range | ±3 A |
| Photometric Accuracy | ±1% |
| Stability | <0.002 A/h |
| Sample Cell | 16 mm round cuvette |
| Data Storage | 1000 measurements, GLP-compliant |
| Display | Backlit LCD (64×128 pixels) |
| Interface | USB 2.0 |
| Protection Rating | IP68 |
| Operating Temperature | 10–40 °C, RH ≤80% |
| Power Supply | USB bus power, AA alkaline/rechargeable batteries, or 12 V automotive adapter |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Certification | CE |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Merckoquant |
| Instrument Type | Laboratory Water Quality Analyzer |
| Target Analytes | Ammonia-Nitrogen, Nitrate, Phosphate |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MERCK |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Analytes | Cyanide, Arsenic, Heavy Metals (Cu, Ni, Cr⁶⁺, Zn, Fe, Mn, Pb, Cd, etc.) |
| Detection Principle | Colorimetric Semi-Quantitative Visual Comparison |
| Compliance | ASTM D3370, ISO 9562, ISO 10530, EN ISO 11732, US EPA Method 9010B (Cyanide), US EPA Method 7196A (Hexavalent Chromium), DIN 38405-27 |
| Brand | Merck Millipore |
|---|---|
| Origin | Germany |
| Model | Prove |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Capacity | 180 water quality parameters |
| Wavelength Range | 190–1,100 nm (UV-Vis) |
| Light Sources | Tungsten-halogen lamp (Prove100), Pulsed xenon lamp (Prove300/Prove600) |
| Spectral Bandwidth | 4 nm (Prove100), 1.8 nm (Prove300/Prove600) |
| Cuvette Compatibility | 16 mm round tubes |
| Display | Resistive touchscreen (Prove100/300), P-cap glass capacitive touchscreen (Prove600) |
| Language Support | 28 built-in languages |
| AQA Levels | AQA 1, AQA 2, pipette accuracy verification |
| Barcode Integration | Full QR-code support for reagent lot, expiry, calibration data, and method traceability |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NOVA30 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Wavelengths | 340, 445, 525, 550, 605, 690 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | −0.300 to 3.200 A |
| Light Source | Tungsten Halogen Lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Cuvette Format | 16 mm round tubes |
| Barcode Method Recognition | Yes |
| AQA Modes | 3 (including zero-point and turbidity correction) |
| Data Storage Capacity | Up to 500 results |
| Interface | RS232-C |
| Real-Time Clock | Integrated |
| Power Supply | 220 V, 50 Hz with optional rechargeable battery |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | −25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.8 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | NOVA60A |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | COD, Total Phosphorus, Total Nitrogen, and over 50 additional water quality parameters |
| Wavelength Range | 340–820 nm (12 fixed wavelengths) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | –0.300 to 3.200 A |
| Cuvette Compatibility | 10 mm, 20 mm, 50 mm square cuvettes and 16 mm round tubes (auto-recognized) |
| Barcode Method Recognition | Yes |
| Light Source | Tungsten halogen lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Quality Control Modes | 3 AQA modes (including zero-point correction and turbidity compensation) |
| Internal Memory | Up to 1000 measurement results |
| User-Defined Methods | Up to 50 custom calibration curves (10 at fixed wavelengths) |
| Real-Time Clock | Yes |
| Interface | RS232C (for PC connection, printer output, and method updates) |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | –25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.3 kg |
| Battery Option | Rechargeable battery available for field use |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectroquant Multy |
| Price | Upon Request |
| Display | 6-digit LCD with backlight |
| Wavelengths | 430 nm, 530 nm, 560 nm, 580 nm, 610 nm, 660 nm (fixed LED sources) |
| Optical Technology | Dual-beam photometry with interference filter compensation |
| Temperature Compensation | 6-point automatic |
| Sample Holders | 16 mm and 24 mm round cuvettes (included) |
| Dimensions (instrument) | 265 × 195 × 70 mm |
| Dimensions (carrying case) | 440 × 370 × 140 mm |
| Interface | RS232 serial port |
| Power Supply | Rechargeable NiCd battery pack (7 cells) |
| Operating Conditions | 0–50 °C, <90% RH (non-condensing) |
| Data Storage | 1000 measurement records with timestamp, parameter ID, and user-defined sample ID |
| Keypad | Chemical-resistant capacitive touch keys |
| Self-Test | Automatic power-on diagnostic routine |
| Compliance | Designed to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 180.1, and EN ISO 15704 for colorimetric water analysis |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | NOVA60 / NOVA60A |
| Instrument Type | Benchtop & Field-Portable Photometric Water Analyzer |
| Wavelength Range | 12 fixed wavelengths (340, 410, 445, 500, 525, 550, 565, 605, 620, 665, 690, 820 nm) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Absorbance Repeatability | ±0.001 A at 1.000 A |
| Absorbance Range | –0.300 to 3.200 A |
| Cell Compatibility | 10/20/50 mm square cuvettes and 16 mm round cells with automatic recognition |
| Barcode Method Recognition | Yes |
| Light Source | Tungsten halogen lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Data Storage | Up to 1,000 results |
| User-Defined Methods | Up to 50 calibration curves |
| Power Supply | 220 V, 50 Hz (NOVA60) |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | –25 °C to +65 °C |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.3 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Pharo 100 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Capability | Multi-Parameter (≥50 parameters) |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical System | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (A < 0.600) |
| Cuvette Compatibility | 16 mm round, 10/20/50 mm square (auto-recognized) |
| Data Storage | 1000 test results + 4 MB for spectral/dynamic data (e.g., 100 scans, 400 kinetics curves) |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS232 |
| Compliance | DIN, US EPA certified methods |
| Power | 100–240 V~, 50–60 Hz |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm |
| Weight | ~3.7 kg (without battery) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Water Quality Analyzer |
| Model | Pharo 300 |
| Instrument Type | Benchtop UV-Vis Spectrophotometer for Water Analysis |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon Flash Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A), ±0.5 % (for 0.600 ≤ A ≤ 2.000 A), ±1.0 % (for A > 2.000 A) |
| Cuvette Compatibility | 16 mm round, and 10/20/50 mm square cuvettes with automatic recognition |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan (1 nm increment), Kinetic Assays |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Connectivity | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, US EPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Enclosure Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L × H × W) |
| Weight | 3.7 kg (without battery) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Pharo100 |
| Price | Upon Request |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A) |
| Cuvette Types | 16 mm round, and 10/20/50 mm square (auto-recognized) |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan, Kinetics |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, USEPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco Cl₂/O₃/pH/ClO₂/CyA |
| Instrument Type | Laboratory & Field-Portable Water Quality Analyzer |
| Optical System | Wavelength-Specific LED Light Source with Interference Filter |
| Measurement Wavelength | 528 nm |
| Measurement Time | 3–4 seconds per test |
| Power Supply | 9-V Alkaline Battery (≈600 measurements per battery) |
| Auto Power-Off | Activated after ≈5 minutes of inactivity |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 30–90 % RH (non-condensing) |
| Compliance | CE-marked per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco F |
| Pricing | Upon Request |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Prove100 / Prove300 / Prove600 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Total Phosphorus, Total Nitrogen |
| Wavelength Range | Prove100: 320–1100 nm |
| Prove300 & Prove600 | 190–1100 nm |
| Light Source | Prove100: Tungsten Halogen Lamp |
| Prove300 & Prove600 | Xenon Flash Lamp |
| Spectral Bandwidth | Prove100 & Prove300: 4 nm |
| Prove600 | 1.8 nm |
| Absorbance Range | ±3.0 Abs |
| Absorbance Resolution | 0.001 Abs |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.1% T at 340 nm (all models) |
| Sample Holders | 16-mm round cuvettes |
| Built-in Methods | Pre-programmed Spectroquant® test protocols + 99 user-defined methods + 20 wavelength-scan/dynamic methods |
| Compliance | EN 61010-1, IEC 61010-1, EN IEC 61326-1, 2004/108/EC |
| IP Rating | IP31 |
| Operating Temperature | 10–35 °C |
| Dimensions | 416 × 276 × 237 mm |
| Weight | 6.8 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Water Quality Analyzers |
| Models | TR320, TR420, TR620 |
| Detection Parameters | COD, Total Phosphorus (TP), Total Nitrogen (TN) |
| Sample Capacity | TR320 – 12 × 16 mm tubes |
| TR420 & TR620 – 24 × 16 mm tubes (TR620 | two independent 12-position blocks) |
| Temperature Range | TR320 – 100 °C, 120 °C, 148 °C (fixed) |
| Temperature Uniformity | ±1.5 °C max deviation between center and peripheral wells |
| Heating Time Range | TR320 – preset only |
| Predefined Programs | 7 standard digestion protocols (e.g., 148 °C/20 min for COD, 120 °C/60 min for TP) |
| User-Defined Programs | TR420 & TR620 support up to 8 custom methods |
| Compliance Features | Optional external temperature probe for analytical quality assurance (AQA) |
| Power Supply | 115 V~ / 230 V~, 50/60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | TR320 – 2.85 kg |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Spectroquant® Move100 |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Total Nitrogen, Total Phosphorus, Free Chlorine, Total Chlorine, Hardness, Phosphate, Sulfate, Iron, Copper, etc. |
| Light Source | LED (430, 530, 560, 580, 610, 660 nm) |
| Wavelength Accuracy | ±2% of range |
| Photometric Range | 0–2 A |
| Linearity Accuracy | ±0.002 A (0–1 A) |
| Linearity Repeatability | ±0.002 A (0–1 A) |
| Wavelength Selection | Automatic |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Data Storage | 1,000 measurements with timestamp, ID, and sample registration |
| Connectivity | IRiM infrared transmitter + PC interface via USB/serial adapter |
| Power Supply | 4 × AA alkaline batteries |
| Ingress Protection | IP68 |
| Weight | 470 g |
| Operating Environment | 0–50 °C, ≤90% RH |
| Included Accessories | Instrument body, carrying case, 4 AA batteries, three 24-mm cuvettes, three 16-mm cuvettes, adapter, mini screwdriver, user manual, certificate of conformity |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Spectroquant® Prove |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | COD, Ammonia-Nitrogen, Total Phosphorus, Total Nitrogen |
| Optical Range | Prove 100 (320–1100 nm), Prove 300/600 (190–1100 nm) |
| Light Source | Tungsten Halogen (Prove 100), Xenon Flash Lamp (Prove 300 & 600) |
| Spectral Bandwidth | 4.5 nm (Prove 100/300), 1.8 nm (Prove 600) |
| Cuvette Compatibility | Round (13 mm, 16 mm) and Rectangular (10 mm, 20 mm, 50 mm, 100 mm) |
| AQA Compliance | Built-in Analytical Quality Assurance per ISO/IEC 17025 and DIN EN ISO 9001 guidelines |
| Data Transfer | USB, Bluetooth, optional Ethernet |
| Software | Spectroquant® Method Manager v5.x with FDA 21 CFR Part 11-compliant audit trail |