Empowering Scientific Discovery

Wuhan Tianhong Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-2024 Atmospheric Photolysis Rate Analyzer
Detection PrincipleBroadband Solar Spectral Irradiance Measurement (280–450 nm)
Detector TypeThermoelectrically Cooled CCD Array Spectrometer
Spectral Resolution≤1.5 nm (FWHM)
Integration Time Range10 ms – 60 s
Output DataJ-value spectra (s⁻¹), wavelength-resolved photolysis rates for NO₂, HCHO, O₃, HONO, and other key atmospheric precursors
ComplianceQ/WTH 206–2022
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelTHM-1200/150
PricingUpon Request
Flow Range0.8–1.2 m³/min
Accuracy±1.5% of reading
Repeatability≤0.5%
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
ComplianceHJ/T 368–2007, Q/WTH 05–2011
Data Storage5000 sets with timestamped T, P, flow, and volume (actual & standard conditions)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelTH-FD747-1
PricingUpon Request
Air Velocity Range0.5–30 m/s
Velocity Uniformity (Relative Standard Deviation)±1.2%
Flow Stability (Relative Standard Deviation)±0.5%
Sound Pressure Level<85 dB(A)
Ambient Temperature Measurement Range−20–100 °C (Accuracy: ±1 °C)
Dynamic Pressure Range0–1.0 kPa (Accuracy: ±1.5%)
Power Supply220 V AC, 50 Hz
Fan Supply380 V AC, 0–50 Hz Variable-Frequency Drive
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Domestic OriginYes
ModelTH-2000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
ModelTH-2200
Sensor TypeIntelligent Electrochemical (Plug-and-Play)
Gas ChannelsUp to 16 (Standard: 4)
Display15-inch IPS Touchscreen (480×800)
Sampling Flow Rate500–800 mL/min (±1.5%)
Operating Temperature−20 °C to +50 °C (±0.5 °C)
Atmospheric Pressure Range76–110 kPa (±200 Pa)
SO₂ Range0–300 mg/m³ (±3.0%)
NO Range0–200 mg/m³ (±3.0%)
NO₂ Range0–40 mg/m³ (±3.0%)
CO Range0–250 mg/m³ (±3.0%)
O₃ Range0–10 mg/m³ (±3.0%)
Enclosure RatingIP3X (Optional Ex-d IIB T4 Explosion-Proof)
ComplianceGBZ 2.1–2007, GB/T 6113, GB/T 16499
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHubei, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelTH-BQX1
PricingUpon Request
Flow Range0.1–150 L/min and 0.8–1.2 m³/min
Flow Measurement Accuracy±1.0% FS
Flow Repeatability≤0.5% RSD
Differential Pressure Range−1000 Pa to +1000 Pa
Differential Pressure Accuracy±1.0% FS
Calibration StandardsTraceable to National Metrology Institute (NIM), certified reference instruments including calibrated infrared photoelectric soap-film flowmeter, infrared photoelectric diaphragm flowmeter, and orifice-type differential pressure flowmeter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-BQX3
ComplianceJJG 577–2005 (Diaphragm Gas Meters), JJG 586–2006 (Soap Film Flowmeters), JJG 640–1994 (Differential Pressure Flowmeters), Q/WTH09–2012 (Enterprise Standard for TH-BQX Series)
PowerRechargeable DC battery, ≥8 h continuous operation
DisplayLarge backlit LCD with Chinese interface
Data HandlingOnboard storage, query, and thermal printing capability
Pressure GenerationIntegrated micro-pressure and gauge-pressure generation modules
DesignCompact, field-portable, microprocessor-controlled architecture
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelTH-ZM10
PricingUpon Request
Flow Range1–30 L/min (field-configurable)
Accuracy ClassClass 1
Display6-digit LCD
Environmental Parameter InputManual entry for ambient temperature and atmospheric pressure
Automatic CompensationSaturation vapor pressure & saturated water temperature lookup per ISO 8573-1 and ASTM D1948 reference tables
Integrated DesignSensor + soap film tube + control electronics in single compact housing
CertificationNationally accredited calibration certificate (CNAS-accredited laboratory)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-ZM8 / TH-ZM10
Measurement Range200–2000 mL/min (extendable upon request)
Accuracy±1.0% of reading
Repeatability≤0.5%
Operating VoltageDC 6 V
Power Consumption0.06–0.3 W
Battery4 × AA cells
Auto Power-Off~6 minutes idle
Display6-digit LCD
Environmental InputManual entry of ambient temperature and atmospheric pressure
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0