Empowering Scientific Discovery

Wuhan Tianhong Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China-made)
ModelTH-300W
PricingUpon Request
Detection PrincipleFlame Ionization Detector (FID) and Electron Capture Detector (ECD)
Instrument TypeOnline Continuous Analyzer
Typical ConfigurationMulti-component VOC & Greenhouse Gas Analyzer
Sampling MethodPressurized Loop Injection with Automated Valving
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCerex
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOpen Path-FTIR
Detection PrincipleFourier Transform Infrared (FTIR) Spectroscopy
Instrument TypeOnline Continuous Emission Monitor
Typical ConfigurationMulti-Gas VOC & HAPs Analyzer
Detection Range0–100 ppb (gas-dependent)
Spectral Resolution0.05–0.5 cm⁻¹ (not nm — corrected per FTIR standard)
Accuracy±1–3% of reading
Response Time1 Hz (1 spectrum per second)
DetectorLiquid-Nitrogen-Free Stirling-Cooled MCT
Cooling SystemIntegrated Stirling Cryocooler (MTBF ≥20,000 hrs)
ConsumablesIR Source & Cryocooler (replacement interval: every 3 years)
Gas Coverage>385 gases, including 100+ EPA-listed Hazardous Air Pollutants (HAPs), acids, aldehydes, aromatics, CFCs, greenhouse gases, hydrocarbons, and combustion byproducts
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-360 Mobile Ambient Air VOC Monitoring System (PTR-MS)
PricingUpon Request
Detection PrincipleProton Transfer Reaction Mass Spectrometry (PTR-MS)
Ionization SourcesDual-mode — H₃O⁺ chemical ionization and Electron Impact (EI)
Mass Range0.4–510 u
Target AnalytesMethanol, Formaldehyde, Formic Acid, Ammonia, Hydrogen Sulfide, and other C₁–C₂₀ volatile organic compounds & odorants
SamplingDirect ambient air intake, no preconcentration membrane
Data OutputReal-time concentration quantification, georeferenced mapping, automated background subtraction, regulatory threshold comparison (HJ 1010–2018)
Compliance ReferenceHJ 1010–2018 “Technical Requirements and Test Methods for Continuous Ambient Air VOC Monitoring Systems Using Gas Chromatography”
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXonteck
OriginUSA
Model901
Instrument TypePortable Automated Canister Sampling System
ComplianceEPA TO-14A & TO-15
Max Canister Capacity16 (optional)
Flow ControlPorter 201 Mass Flow Controller (0–20 / 0–50 / 0–100 sccm, ±1% FS linearity & accuracy)
Display5.7" TFT color touchscreen (320 × 240 px, white LED backlight)
Internal PumpAD B161 stainless steel diaphragm pump (max vacuum: 23.0" Hg
max flow7.6 L/min)
Pressure SensingDigital sensors for canister (−30" Hg to +30 psig, 0.1" Hg / 0.1 psig res.) and pump (0–30 psig, 0.1 psig res.)
Pressure RegulationSwagelok SS regulator (3–50 psig / 0.21–3.5 bar)
Temperature ControlIntegrated 100 W silicone heater with Honeywell RTD (−40 °C to +150 °C)
Enclosure MaterialStainless steel, PTFE, Viton® wetted surfaces
Power115 V/60 Hz or 220 V/50 Hz (selectable)
Dimensions7" H × 19" W × 13" D
Weight9.07 kg (20 lbs)
CommunicationRS-232, Ethernet, optional 2400-baud modem
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-305 VOCs Hydrogen Generator
Hydrogen Purity≥99.999%
Flow Rate Range0–300 mL/min
Output ControlAutomatic Flow Tracking & Electrolyzer Power Modulation
DisplayLCD with Real-time Parameter Monitoring
Safety ProtectionsOverpressure, Overtemperature, Low-Water, and High-Water Level Interlocks
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions360 × 280 × 520 mm
Weight~22 kg
ComplianceCE-marked (per EN 61000-6-3/6-4, EN 61010-1), Designed for GLP-Compatible Lab Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-300L
Detection PrincipleGas Chromatography–Flame Ionization Detection–Mass Spectrometry (GC-FID-MS)
Instrument TypeOnline Analyzer
Typical ConfigurationIntegrated VOC Speciation Analyzer
Sampling MethodProgrammable Interval-Based Whole-Air Sampling with Cryogenic Preconcentration
Detection Range0–50 nmol/mol (pptv-level)
Accuracy±10% of Reading
Compliance StandardHJ 1010–2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-303 Online Dynamic Dilution System
Gas Channels4 (1 diluent + 3 standard gases)
Flow Control4 independent mass flow controllers (MFCs)
InterfaceLCD touchscreen with local/remote control capability
Communication ProtocolRS-485 or Ethernet (Modbus TCP/RTU supported)
Safety FeatureReal-time heartbeat monitoring with automatic gas shutoff upon communication failure
ExpandabilityModular design supports additional gas channels
IntegrationDesigned for seamless integration with Tianhong TH-300B calibration and reference gas delivery platform
ComplianceEngineered to support EPA Method TO-14A/TO-15, ASTM D6196, and ISO 16017-1 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCerex
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelOpen Path UV-DOAS
Detection PrincipleUltraviolet Differential Optical Absorption Spectroscopy (UV-DOAS)
Instrument TypeOnline Continuous Emission Monitor
Typical ConfigurationMulti-Component VOC & Inorganic Gas Analyzer
Detection Range0.1–10 ppb (gas-dependent)
Resolution0.1 ppb
Accuracy±0.1% of full scale
Response Time<1 s
Optical Path Length0–2000 m
ComplianceASTM D6348, ISO 12039, EN 15267-3 (configurable), US EPA Method TO-14/TO-15 compatible (with optional calibration gas manifold)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-318 Ambient Air TVOC Online Monitoring System
Price RangeUSD 5,600 – 8,400 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelTH-307 VOCs Zero Air Generator
Price RangeUSD 2,800 – 4,200
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelTH-303 Offline Dynamic Dilution System
Price RangeUSD 16,800 – 25,200 (based on exchange rate ~¥120,000–¥180,000)
Dilution RatioUp to 1:1500 (minimum achievable concentration dependent on source gas purity and flow stability)
Output PressureUp to 35 psi (gauge) without external booster
Gas Pathways3 independent MFC-controlled channels
Control InterfaceLCD touchscreen with parameter-driven dilution logic
Compliance ReferenceHJ 759–2015 — Ambient Air—Determination of Volatile Organic Compounds (VOCs) by Canister Sampling Coupled with GC-MS
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelX-Can Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-2020 Atmospheric PANs Online Monitoring System
Price RangeUSD 110,000 – 205,000
Detection PrincipleGas Chromatography with Electron Capture Detection (GC-ECD)
Calibration MethodOn-site Photochemical Synthesis of PAN Standard Gas
Detection Limit≤ 50 ppt (PAN)
Analysis Cycle≤ 5 min
Temperature ControlTEC-cooled column oven down to 5 °C
Carrier Gas ControlElectronic Pressure Control (EPC)
Calibration Accuracy±1% F.S. (MFCs)
PAN Generation Efficiency>96%
ComplianceDB35/T 1521–2015, JJG 1055–2009
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
Model910
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-300B/H
Detection PrincipleGas Chromatography–Mass Spectrometry (GC-MS) with Flame Ionization Detection (FID)
Instrument TypeOnline Analytical System
Typical ConfigurationIntegrated VOC Speciation Analyzer
Sampling MethodActive Whole-Air Sampling with Cryogenic Preconcentration
Detection Range0–50 nmol/mol (ppbv)
Accuracy±10% of Reading
Compliance StandardHJ 1010–2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-300L (I / II / III) VOC Pre-concentrator
Cooling Temperature Range-190 °C (adjustable) for trapping
Water Removal Temperature-60 °C (adjustable)
ComplianceHJ 1010–2018, HJ 759–2015
Sample InterfaceUniversal GC/GC-MS compatible
Detection CompatibilityFID, FPD, ECD, MS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-300F Online Ambient Air VOC Monitoring System (ODS/HFC)
Sampling MethodNegative-Pressure Cryogenic Preconcentration
Detection PrincipleGas Chromatography–Mass Spectrometry (GC-MS)
Enrichment Temperature Range–190 °C to –40 °C (adjustable)
Water Removal Temperature Range–60 °C to 0 °C (adjustable)
Minimum Sampling Duration≥30 min
Typical LOD<0.3 ppt (for most target compounds)
Precision (RSD at 50 ppt)≤2%
Target Analytes36 ODS and HFC compounds (e.g., CFC-11, CFC-12, HCFC-22, HFC-134a, HFC-152a, Halon-1211, etc.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-300C Continuous Ambient Air Non-Methane Hydrocarbons (NMHC) Monitoring System
Detection PrincipleCryogenic Preconcentration + Thermal Desorption + Flame Ionization Detection (FID)
Compliance StandardHJC-ZY84-2020
CalibrationAutomated Dynamic Dilution Calibrator
Sample IntroductionDirect Ambient Air Intake (No Adsorbent Trap)
Measurement Range0–10 ppmv (as Carbon, adjustable via dilution)
Detection Limit<50 ppbv (as Carbon, 3σ)
Analysis Cycle≤5 min per measurement
Operating Temperature Range5–35 °C
Power Supply220 VAC ±10%, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model912
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-852
PricingAvailable Upon Request
Measurement PrincipleExtractive FTIR Spectroscopy
Spectral Range2.5–12 µm
Target Analytes>300 IR-active compounds including VOCs and HAPs
Response Time<1 s per spectrum
ComplianceEPA Method 300, JJG 700–1999
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
ModelTH-300B/H/L/G
OriginHubei, China
Detection PrincipleCryogenic Preconcentration + Dual-FID GC
Target Analytes57 PAMS Compounds
Sampling Interval≥30 min
Cryogenic Trapping TemperatureAdjustable down to −190 °C
Water Removal TemperatureAdjustable down to −60 °C
ComplianceHJ 1010–2018
Detector OptionsFID (standard), FPD (for sulfur compounds), ECD (for halocarbons)
Application ScopeAmbient air monitoring stations, residential zones, scenic areas, industrial parks
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-309 Formaldehyde Online Ambient Air Monitor
Detection PrincipleAcetylacetone Colorimetric Method (UV-Vis at 413 nm)
Measurement Range0–5 mg/m³ (configurable)
Detection Limit≤0.01 mg/m³
Sampling Flow Rate0.5–2.0 L/min
Operating Temperature0–40 °C
Relative Humidity≤90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz
Data Storage≥6 months (internal flash memory, power-loss resistant)
ComplianceGB/T 15516–1995
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-302B Sampling Canister Cleaning System
Vacuum Performance≤50 mtorr (base pressure), 100 L/min free-air displacement
CapacitySimultaneous cleaning of up to 4 × 15 L canisters (expandable to 8)
Display7-inch capacitive touchscreen interface
Construction MaterialsSS316 and PTFE throughout gas path (valves, fittings, tubing)
ComplianceDesigned per HJ 759–2015 “Determination of Volatile Organic Compounds in Ambient Air — Canister Sampling GC-MS Method”
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-830 Fixed Source VOC Online Monitoring System (Gas Chromatography-Based)
Price RangeUSD 25,000 – 39,000