Empowering Scientific Discovery

Wuhan Tianhong Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-990F(III)
Instrument TypePortable Flue Gas Analyzer
Measurement Accuracy (Full Scale)±5%
Repeatability±2%
Response Time (T90)90 s
Drift (24 h)±5%
Measured GasesSO₂, CO, NO, NO₂, O₂
Display5.7-inch 4-level grayscale LCD with full-touch interface
Power SupplyAC/DC dual-mode
Dimensions380 × 170 × 265 mm
Weight6 kg
Data Storage Capacity>100,000 records
ComplianceGB/T 16157–1996, HJ/T 46–1999, JJG 968–2002, HJ 693–2014, Q/WTH 07–2013
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-110E
Instrument TypeDual-Channel Constant-Flow Air Sampler
Flow ControlMicroprocessor-Controlled Constant Flow
Power SupplyRechargeable DC Battery (≥20 h runtime)
ComplianceHJ/T 375–2007, JJG 956–2013, GB/T 17061–1997, HJ 644–2013
Display & InterfaceFull Chinese LCD with Real-Time Parameter Feedback
Environmental SensorsIntegrated Barometric Pressure & Ambient Temperature Measurement
Data LoggingDual-Channel Independent Volume Accumulation (Actual & Standard Conditions), Onboard Historical Storage
CalibrationSoftware-Based Pressure & Flow Calibration Functionality
Physical DesignCompact, Lightweight, Field-Deployable Chassis
Sampling ModesTimed, Volume-Triggered (Actual or Standard), and Conditional (e.g., Workload-Based) Sampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYuhong
OriginHubei, China
ModelTH-2000PM Portable
Measurement PrincipleBeta-ray Absorption (β-ray)
Measured ParametersPM₁₀ and PM₂.₅
ComplianceHJ 653–2013
Display7-inch HD Touchscreen (Chinese UI)
Data StorageHourly internal logging
CommunicationBuilt-in GPRS module, digital output interface
Optional ModulesMeteorological sensors (wind speed/direction), GPS, noise monitoring, video capture
Radiation SourceLow-activity ¹⁴C beta source (licensed per Chinese radiation safety regulations)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
ModelTH-880W (Wireless)
OriginHubei, China
ComplianceGB/T 16157–1996, HJ/T 47–1999, HJ/T 48–1999, Q/WTH 06–2013
Wireless Control Range~100 m
Power Consumption<70 W
Data Storage Capacity>100,000 records
Sensor InterfaceUp to 8 electrochemical gas sensors (4 standard, 4 expandable)
Flow MeasurementV-cone differential pressure flow sensor
Moisture RemovalMulti-stage condensation dehydration unit (≥70% efficiency)
Operating ModesAC/DC dual power supply
EMC/EMI ComplianceYes
GPS IntegrationBuilt-in geotagging support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
ModelTH-2000PM
Measurement PrincipleBeta-ray attenuation (¹⁴C source)
Particle Size CutsTSP, PM₁₀, PM₂.₅, PM₁
Operating Temperature-30 °C to 50 °C
Relative Humidity Range0–90% RH (non-condensing)
Flow ControlPID-regulated mass flow controller with digital sensor
Data Storage≥1 year of 1-minute resolution data (internal flash + USB export)
Display7-inch capacitive touch screen (Chinese UI)
Communication InterfacesRS-232, RS-485, 10/100 Mbps Ethernet, 4–20 mA analog output
Radiation Source¹⁴C (half-life: 5730 years
Power SupplyAC 220 V ±10%, 50 Hz
Enclosure RatingIP54
ComplianceMeets technical requirements of HJ 653–2013 (China), compatible with GB/T 15432–1995 and ISO 10473:2000 for gravimetric equivalence validation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-680
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-2026
Detection PrincipleGas Correlation Infrared Absorption
Measurement RangeLow-concentration CH₄ in ambient air and flue gas
Output Unitsmg/m³, µg/m³, nmol/mol, µmol/mol, ppm, ppb
Display7-inch full-touch color LCD
Data LoggingOne year of stored records (5-minute intervals)
Environmental CompensationAutomatic temperature & pressure compensation
Remote CapabilityRemote calibration & diagnostic parameter access
Filter WheelEngineered gas-correlation wheel with CH₄/N₂ spectral filters
Compliance ContextDesigned for continuous emission monitoring (CEM) in accordance with China’s HJ 1012–2018 and compatible with international ambient air quality reference methodologies (e.g., ISO 13964, ASTM D6522)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China-made)
ModelTH-300W
PricingUpon Request
Detection PrincipleFlame Ionization Detector (FID) and Electron Capture Detector (ECD)
Instrument TypeOnline Continuous Analyzer
Typical ConfigurationMulti-component VOC & Greenhouse Gas Analyzer
Sampling MethodPressurized Loop Injection with Automated Valving
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelXC-30B
Instrument Type24-Hour Temperature- and Flow-Controlled Gas Sampler
ConfigurationSingle-Channel Gas Sampler
Flow Range0.1–2500 mL/min
Maximum Vacuum Pressure30 kPa
Flow Stability±5% over 24 h
Flowmeter Accuracy±2.5% FS (dry gas meter), ±2% FS (mass flow sensor)
Rated Service Life at Max Flow & Backpressure5000 hours
Continuous Operation Time at Max Flow & Backpressure8 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-2003BZ
Price RangeUSD 70,000 – 140,000 (FOB)
Certified Pollutant ParametersSO₂, NO₂, O₃, CO
ComplianceGB 3095–2012, HJ 654–2013
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-502(ZX)
Instrument TypeOnline
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Max. Permissible Error±10%
Zero Drift±1% FS/24h
Span Drift±2% FS/24h
Repeatability±1% FS
ComplianceGB 3847–2005, HJ/T 395–2007, JJG 976–2010, Q/WTH 34–2012
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYuhong
ModelTH-2001H
Detection PrincipleChemiluminescence (CLD)
Measurement SpeciesNO, NO₂, NOₓ (NO + NO₂)
Display7-inch full-touch color LCD
Concentration Unitsppb, ppm, µg/m³, mg/m³
Automatic Range SwitchingYes
Temperature & Pressure CompensationIntegrated
Data Logging Interval5-minute resolution
Storage CapacityHigh-capacity internal memory
Sampling SystemDual-path, time-shared single-channel with electromagnetic valve switching
O₃ GeneratorPatented micro-ozone generator (ZL201220024333.0)
NO₂-to-NO ConverterIntegrated catalytic converter with patented NO₂ reduction and O₃ removal module (ZL201020245767.8)
Remote CapabilitiesRemote calibration, real-time diagnostics, parameter monitoring
Alarm FunctionsMulti-parameter configurable alarms
Compliance SupportDesigned for continuous ambient air monitoring per EPA Method 42, ISO 7935:1990, and EN 14211:2012
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelZRE
Instrument TypeContinuous Emission Monitoring System (CEMS)
Indication Error±1% FS
Repeatability≤1% FS
Response Time (T90)≤1 s
Stability (24 h)≤1% FS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-2008H
Display7-inch full-touch color LCD
InterfaceChinese menu-based UI
ProgrammabilityUp to 100 program/sequence segments
CompensationAutomatic temperature & pressure compensation
CommunicationRS232, RS485, USB, Ethernet
Remote capabilityRemote zero/span command execution & internal parameter diagnostics
AlarmMulti-parameter fault alerting
O₃ generationOnboard ozone generator with 16-point certified calibration
Calibration methodDynamic dilution of certified standard gases with zero air
Target analytesSO₂, NO, NO₂, O₃, CO, NOₓ (via gas-phase titration)
Compliance contextDesigned for compliance with EPA Protocol Gas Certification requirements, ISO 17025 traceable calibration workflows, and GLP/GMP-aligned instrument qualification (IQ/OQ)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHebei, China
ModelTH-16Ea
Sampling Flow Rate16.67 L/min (constant flow)
Flow Range for Mass Concentration Measurement0–1000 µg/m³
Filter Capacity16 filters per unattended cycle
ComplianceDesigned for ISO 7708, EN 12341, EPA Method IO-3.3, and GB/T 37186–2018 compliant PM10/PM2.5 monitoring
Power SupplyAC 220 V ±10%, 50 Hz
Operating Environment−30 °C to +50 °C, IP55 rated enclosure
Data StorageInternal flash memory ≥3 years (timestamped, audit-trail enabled)
CommunicationUSB 2.0 host port, optional GPRS module (LTE-M/NB-IoT compatible), optional analog/digital I/O for wind speed/direction sensors
NFC InterfaceISO/IEC 14443-A compliant embedded tag in filter holder
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
ModelTH-2012
Measurement PrincipleForward scatter photometry
Visibility Range10 m to 50,000 m
Output Interval30–300 s (configurable)
Rainfall Measurement Range0.15–250 mm/h
Rainfall Accuracy≤10%
Optical SourcePulsed infrared LED
Environmental RatingIP65
Power ConsumptionLow-power design for unattended operation
ComplianceDesigned for integration into automated environmental monitoring networks compliant with WMO No. 8 and GB/T 35222–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYuhong
ModelTH-2001H
Detection PrincipleChemiluminescence (CLD)
Measurement ParametersNO, NO₂, NOₓ (calculated)
Display7-inch capacitive touchscreen
Unitsppb, ppm, µg/m³, mg/m³ (user-selectable)
Data LoggingInterval-stamped records every 5 minutes
Power SupplyRechargeable Li-ion battery (≥5 h operation) + AC adapter
Operating Environment0–40 °C, 10–90% RH (non-condensing)
ComplianceDesigned for field-deployable environmental monitoring per EPA Method 42 & ISO 7935 (principles), GLP-aligned data integrity
Gas PathDual-stream, time-shared single reaction chamber with catalytic NO₂-to-NO converter
Automatic CompensationTemperature and barometric pressure
ConnectivityRemote calibration & diagnostics via embedded communication interface
AlarmMulti-parameter configurable thresholds
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCerex
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOpen Path-FTIR
Detection PrincipleFourier Transform Infrared (FTIR) Spectroscopy
Instrument TypeOnline Continuous Emission Monitor
Typical ConfigurationMulti-Gas VOC & HAPs Analyzer
Detection Range0–100 ppb (gas-dependent)
Spectral Resolution0.05–0.5 cm⁻¹ (not nm — corrected per FTIR standard)
Accuracy±1–3% of reading
Response Time1 Hz (1 spectrum per second)
DetectorLiquid-Nitrogen-Free Stirling-Cooled MCT
Cooling SystemIntegrated Stirling Cryocooler (MTBF ≥20,000 hrs)
ConsumablesIR Source & Cryocooler (replacement interval: every 3 years)
Gas Coverage>385 gases, including 100+ EPA-listed Hazardous Air Pollutants (HAPs), acids, aldehydes, aromatics, CFCs, greenhouse gases, hydrocarbons, and combustion byproducts
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTH-360 Mobile Ambient Air VOC Monitoring System (PTR-MS)
PricingUpon Request
Detection PrincipleProton Transfer Reaction Mass Spectrometry (PTR-MS)
Ionization SourcesDual-mode — H₃O⁺ chemical ionization and Electron Impact (EI)
Mass Range0.4–510 u
Target AnalytesMethanol, Formaldehyde, Formic Acid, Ammonia, Hydrogen Sulfide, and other C₁–C₂₀ volatile organic compounds & odorants
SamplingDirect ambient air intake, no preconcentration membrane
Data OutputReal-time concentration quantification, georeferenced mapping, automated background subtraction, regulatory threshold comparison (HJ 1010–2018)
Compliance ReferenceHJ 1010–2018 “Technical Requirements and Test Methods for Continuous Ambient Air VOC Monitoring Systems Using Gas Chromatography”
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-880
Instrument TypePortable Flue Gas & Particulate Sampler
Sensor IntegrationOptional electrochemical sensors (SO₂, CO, O₂, NOₓ)
Compliance BasisDesigned for compliance with GB/T 16157–1996, HJ/T 48–1999, and ISO 9096:2003 principles
Operating PrinciplePitot-static parallel isokinetic sampling with real-time velocity tracking
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-J3
ComplianceJJG 577–2005 (Diaphragm Gas Meter Verification Regulation), Q/WTH42–2013 (Enterprise Standard for TH-J Series Pressure-Flow Calibrators)
PowerRechargeable Lithium Battery (20 h continuous operation)
DisplayHigh-Brightness Chinese Character OLED
Data Storage20 measurement records
Environmental SensorsIntegrated barometric pressure & ambient temperature measurement
Dimensions & PortabilityCompact, lightweight, field-deployable design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-2000PMc
Measured ParametersTSP, PM10, PM2.5
Detection PrincipleBeta-ray attenuation with integrated dynamic heating system (DHS) and optical scattering compensation
Data Storage Capacity≥2 years (internal flash memory)
Power SupplyAC 220 V ±10% or built-in 25 Ah Li-ion battery (≥24 h backup)
Communication InterfacesGPRS/3G/4G wireless, RS232, RS485, USB
Display4.3-inch capacitive touchscreen
Environmental RatingIP55 for outdoor all-weather operation
Mounting OptionsTripod, pole-clamp, rooftop, or wall-mount
ComplianceMeets Chinese EPA HJ 653–2013 and HJ 93–2013 technical requirements for reference methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhong
OriginHubei, China
ModelTH-230
Measurement PrincipleCapacitive-Resistive (Capacitance & Resistance Hybrid) Sensor Technology
Display7-inch capacitive touchscreen with hex-grid real-time data layout
Data StorageInternal non-volatile memory (≥10,000 records)
Operating Temperature Range-20 °C to +60 °C
Protection RatingIP54
Power SupplyRechargeable Li-ion battery (≥8 h continuous operation)
Gas CompatibilityFlue gas, stack emissions, ambient air, industrial process streams
ComplianceMeets GB/T 16157–1996, HJ/T 397–2007, and ISO 12141:2021 (Humidity measurement in hot, wet, and dusty gas streams)