- All
- Favorite
- Popular
- Most rated
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | AASS |
| Sound Output Range | 20 Hz – 25.5 kHz (audio), 20 Hz – 20 kHz (white noise) |
| Max SPL | 128 dB |
| Stimulus Control | Computer-controlled amplitude, frequency, duration, rise/fall time |
| Optional Modules | Footshock (up to 3.0 mA), Visual Flash Stimulus |
| Chamber Configuration | Single or 8-chamber sound-attenuated enclosures |
| Data Acquisition | Analog signal conditioning (amplification + integration), 16-bit ADC |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | BLS |
|---|---|
| Origin | Hungary |
| Model | CF-150C |
| Pulse Voltage Range (Square Wave) | 12–185 V |
| Pulse Duration | 10–200 µs |
| Inter-Pulse Interval | 200 µs |
| Pulse Count | 1–10 |
| HF Oscillator Frequency | 1 MHz ±100 Hz |
| HF Amplitude (Coarse) | 0–30 V<sub>eff</sub> |
| HF Amplitude (Fine) | 0–3 V<sub>eff</sub> |
| Operating Medium | Electrolytic or Non-electrolytic Solutions |
| Dimensions | 200 × 130 × 45 mm |
| Weight | 380 g |
| Power Consumption | 15 VA |
| Protection Class | Class I (Earthed) |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Model 524 |
| Electrode Type | Reusable tweezer-style in vivo electroporation electrode |
| Electrode Disk Diameter Options | 7 mm (Model 520) or 10 mm (Model 523) |
| Adjustable Inter-Electrode Gap | <1 mm to >20 mm |
| Compatible Pulse Generators | BTX ECM 830, ECM 630, ECM T820, ECM 2001 |
| Electrode Material | Stainless steel |
| Sterilization Method | Ethanol or ethylene oxide |
| Connection | BTX Model 524 Cable |
| Compliance | Designed for GLP-compliant preclinical research workflows |
| Brand | BLS |
|---|---|
| Origin | EU-manufactured |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | European Union |
| Model | CF150B |
| Pricing | Available upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SurgiVet V6004 |
| Pricing | Available Upon Request |
| Brand | HEKA (now part of Harvard Bioscience) |
|---|---|
| Origin | Germany (manufactured in Lambrecht, Germany |
| Model | EPC 10 USB |
| Architecture | Integrated analog amplifier + digital I/O (LIH 8+8 AD/DA interface) |
| Interface | High-speed USB 2.0 |
| Configurations | Single-, dual-, triple-, and quad-patch headstage options |
| Compatible Software | PatchMaster v2.x / PatchMaster Next, FitMaster, SmartLux |
| Compliance | CE-marked, RoHS-compliant, designed for GLP/GMP-adjacent electrophysiology labs |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RWD Standard Stereotaxic Instrument |
| Price Range | USD 7,000 – 14,000 |
| Frame Design | U-shaped rigid cast aluminum architecture |
| Motion Axes | X/Y/Z with 80 mm travel per axis |
| Positioning Resolution | 100 µm (micrometer-scale vernier scale) |
| Rotation Capability | 360° horizontal azimuthal rotation, 180° vertical elevation adjustment with mechanical locking |
| Scale Marking | Laser-etched dual-scale graduations (mm and 0.1 mm) |
| Drive Mechanism | Dual-lead precision brass-on-steel micrometer screws |
| Surface Treatment | Anodized aluminum frame and base plate for wear resistance and autoclave-compatible cleanability |
| Animal Adapter | Curved craniomandibular contour design for rat skull conformity |
| Ear Bar Fixation | Dual-side compression plate locking system |
| Compatibility | Integrated mounting interfaces for microinjection pumps (e.g., RWD KDS200 series), stereomicroscopes (Leica MZ10F, Olympus SZX16), and cranial drill systems (RWD 60000 series) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | IPA |
| Type | Integrated Electrophysiology Amplifier System with Built-in ADC/DAC |
| Compliance | Designed for Whole-Cell, Cell-Attached, and Voltage/Current-Clamp Recordings |
| Software | SutterPatch v3.x (Real-Time Analysis, Multi-View Oscilloscope, Audit-Trail Data Archiving) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 38450 |
| Force Range | 0–1000 g |
| Force Resolution | 0.1 g |
| Observation System | Integrated Triangular Prism Viewing Platform |
| Data Storage | Onboard memory for >100 test sessions |
| Stimulus Control | User-adjustable ramp rate and inter-stimulus interval |
| Compliance | Designed for GLP-compliant rodent nociception studies |
| Accessories | Optional grip bar, mesh floor platform (5 × 5 mm² laser-cut apertures, 1 mm spacing), calibrated von Frey filament sets (37450/277, 0.008–300 g) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanoliter2000 |
| Pricing | Upon Request |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 33 or 33T |
| Light Source Intensity Range | 0–250 (arbitrary units, ±1% accuracy) |
| Focal Spot Size | 4 × 6 mm |
| Reaction Time Resolution | 0.01 s |
| Preheating Temperature Range | 0–75 °C |
| Automatic Cut-off Timer | User-configurable |
| Data Output | RS-232 serial interface + thermal printer support |
| Compliance | Designed for GLP-compliant preclinical analgesia studies |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal Programmable Micropipette Puller |
| Heating Mechanism | Dual-Independent Filament (Tungsten/Platinum) |
| Control Architecture | Microprocessor-Based with Ramp Detection Algorithm |
| Program Storage | 100 User-Defined Protocols with Write-Protection and Timestamping |
| Electrode Symmetry | Dual-Output Symmetric Pulling |
| Tip Diameter Reproducibility | Sub-100 nm (verified by SEM) |
| Integrated Gas System | Regulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization |
| Display | Vacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 454 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | C76688 |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | TC-3000 |
| Input Channels | Single or Triple Thermocouple |
| Temperature Range (Single-Channel) | 25.0–45.0 °C (0.1 °C resolution, Celsius only) |
| Temperature Range (Triple-Channel) | −10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution |
| Sampling Rate | 3 Hz per channel |
| Power Supply | 4 × C-cell batteries (included) |
| Output | Analog voltage output (0–5 V DC, proportional to temperature) |
| Display | Front-panel LCD with manual channel selection |
| Compliance | CE-marked, RoHS-compliant, designed for laboratory use under GLP conditions |
| Brand | BLS |
|---|---|
| Model | FBL/Basic-B&N-01 |
| Power Supply | Dual-mode (battery or AC/DC adapter) |
| Excitation Wavelength Range | 470–660 nm |
| Emission Detection Range | 500–650 nm |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE8815 / LE8816 |
| External Dimensions | 450 × 450 × 200 mm or 220 × 220 × 200 mm |
| Infrared Frame Options | 450 × 450 mm (32 sensors, 25 mm spacing) or 250 × 250 mm (32 sensors, 13 mm spacing) |
| IR Wavelength | 950 nm |
| Sampling Frequency | 40 Hz |
| Software | Acti-Track v5.x |
| Max Concurrent Channels | 32 |
| Configurable Zones | Single-animal or dual-animal (split-zone) mode |
| Behavioral Metrics | Distance traveled, velocity profiles (max/min/mean), time-in-zone, zone entries, rearing count & duration, rotation counts, trajectory-based path analysis, nose-poke detection (threshold-defined), ambulation classification (fast/slow/immobility) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PP35-2P |
| Type | Adherent-cell-specific electroporation electrode |
| Compatibility | Standard 35 mm Petri dishes with 2 mm gap electrodes |
| Application | In situ transfection of monolayer-cultured mammalian cells |
| Configuration | Dual parallel plate electrode assembly |
Show next