Empowering Scientific Discovery

Youcheng Biotechnology Co., Ltd. (Hong Kong)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCOULBOURN
OriginUSA
ModelAASS
Sound Output Range20 Hz – 25.5 kHz (audio), 20 Hz – 20 kHz (white noise)
Max SPL128 dB
Stimulus ControlComputer-controlled amplitude, frequency, duration, rise/fall time
Optional ModulesFootshock (up to 3.0 mA), Visual Flash Stimulus
Chamber ConfigurationSingle or 8-chamber sound-attenuated enclosures
Data AcquisitionAnalog signal conditioning (amplification + integration), 16-bit ADC
ComplianceDesigned for GLP-compliant behavioral phenotyping workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBLS
OriginHungary
ModelCF-150C
Pulse Voltage Range (Square Wave)12–185 V
Pulse Duration10–200 µs
Inter-Pulse Interval200 µs
Pulse Count1–10
HF Oscillator Frequency1 MHz ±100 Hz
HF Amplitude (Coarse)0–30 V<sub>eff</sub>
HF Amplitude (Fine)0–3 V<sub>eff</sub>
Operating MediumElectrolytic or Non-electrolytic Solutions
Dimensions200 × 130 × 45 mm
Weight380 g
Power Consumption15 VA
Protection ClassClass I (Earthed)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBTX
OriginUSA
ModelBTX Model 524
Electrode TypeReusable tweezer-style in vivo electroporation electrode
Electrode Disk Diameter Options7 mm (Model 520) or 10 mm (Model 523)
Adjustable Inter-Electrode Gap<1 mm to >20 mm
Compatible Pulse GeneratorsBTX ECM 830, ECM 630, ECM T820, ECM 2001
Electrode MaterialStainless steel
Sterilization MethodEthanol or ethylene oxide
ConnectionBTX Model 524 Cable
ComplianceDesigned for GLP-compliant preclinical research workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBLS
OriginEU-manufactured
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginEuropean Union
ModelCF150B
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelSurgiVet V6004
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEKA (now part of Harvard Bioscience)
OriginGermany (manufactured in Lambrecht, Germany
ModelEPC 10 USB
ArchitectureIntegrated analog amplifier + digital I/O (LIH 8+8 AD/DA interface)
InterfaceHigh-speed USB 2.0
ConfigurationsSingle-, dual-, triple-, and quad-patch headstage options
Compatible SoftwarePatchMaster v2.x / PatchMaster Next, FitMaster, SmartLux
ComplianceCE-marked, RoHS-compliant, designed for GLP/GMP-adjacent electrophysiology labs
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelRWD Standard Stereotaxic Instrument
Price RangeUSD 7,000 – 14,000
Frame DesignU-shaped rigid cast aluminum architecture
Motion AxesX/Y/Z with 80 mm travel per axis
Positioning Resolution100 µm (micrometer-scale vernier scale)
Rotation Capability360° horizontal azimuthal rotation, 180° vertical elevation adjustment with mechanical locking
Scale MarkingLaser-etched dual-scale graduations (mm and 0.1 mm)
Drive MechanismDual-lead precision brass-on-steel micrometer screws
Surface TreatmentAnodized aluminum frame and base plate for wear resistance and autoclave-compatible cleanability
Animal AdapterCurved craniomandibular contour design for rat skull conformity
Ear Bar FixationDual-side compression plate locking system
CompatibilityIntegrated mounting interfaces for microinjection pumps (e.g., RWD KDS200 series), stereomicroscopes (Leica MZ10F, Olympus SZX16), and cranial drill systems (RWD 60000 series)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelTable Top
Gas Delivery SystemNon-rebreathing, single-circuit
Vaporizer TypeTECH3 Isoflurane/Sevoflurane
Flow Range0–1000 mL/min (O₂)
Vapor Output Range0.5–5%
Weight~10 kg (unit + vaporizer)
Safety FeaturesVaporizer lockout, visual drug level window, activated carbon scavenging system
ComplianceASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSutter
OriginUSA
ModelIPA
TypeIntegrated Electrophysiology Amplifier System with Built-in ADC/DAC
ComplianceDesigned for Whole-Cell, Cell-Attached, and Voltage/Current-Clamp Recordings
SoftwareSutterPatch v3.x (Real-Time Analysis, Multi-View Oscilloscope, Audit-Trail Data Archiving)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUgo Basile
OriginItaly
Model38450
Force Range0–1000 g
Force Resolution0.1 g
Observation SystemIntegrated Triangular Prism Viewing Platform
Data StorageOnboard memory for >100 test sessions
Stimulus ControlUser-adjustable ramp rate and inter-stimulus interval
ComplianceDesigned for GLP-compliant rodent nociception studies
AccessoriesOptional grip bar, mesh floor platform (5 × 5 mm² laser-cut apertures, 1 mm spacing), calibrated von Frey filament sets (37450/277, 0.008–300 g)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelGemini SC2
WaveformsSquare Wave & Exponential Decay Wave
Voltage Range (LV)5–500 V (1 V step), 505–3000 V (5 V step)
Voltage Range (HV)10–500 V (5 V step), 510–3000 V (10 V step)
Pulse Duration (Square, LV)10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms)
Pulse Duration (Square, HV)10 µs–600 µs (1 µs)
Pulse Duration (Exponential, LV)1.25 ms–3.275 s (1.25 ms)
Pulse Duration (Exponential, HV)0.5 ms–50 ms (0.5 ms)
Pulse Number (Square)1–10 (LV), 1–3 (HV)
Pulse Number (Exponential)1–12 (R < 100 Ω), 1–24 (R > 100 Ω)
Pulse Interval0.1–10 s (Square), 5–30 s (Exponential)
Capacitance (LV)3775 µF (fixed)
Capacitance (HV)85 µF (fixed)
Capacitance (Exponential, LV)25–3275 µF (25 µF step)
Capacitance (Exponential, HV)10, 25, 50 µF (selectable)
Resistance Measurement Range25–1575 Ω (25 Ω step, LV)
DisplayTouchscreen Interface
Preloaded ProtocolsYes
Arc SuppressionActive
Short-Circuit ProtectionIntegrated
ComplianceCE, RoHS, FDA-listed device (Class II)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNanoliter2000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUgo Basile
OriginItaly
Model33 or 33T
Light Source Intensity Range0–250 (arbitrary units, ±1% accuracy)
Focal Spot Size4 × 6 mm
Reaction Time Resolution0.01 s
Preheating Temperature Range0–75 °C
Automatic Cut-off TimerUser-configurable
Data OutputRS-232 serial interface + thermal printer support
ComplianceDesigned for GLP-compliant preclinical analgesia studies
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelAS-01-006
Oxygen Inlet Pressure50 PSI (fixed)
Max Oxygen Flow50 LPM (safety-limited)
Adjustable O₂ Flow Range0–4 LPM
Isoflurane Vaporizer Range0.5–5.0%
CO₂ Absorber Capacity3 lb (1.36 kg)
Dimensions (L×W×H)40 × 35.5 × 85 cm
ComplianceASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelCDS 9000
CertificationCE, ISO 13485
Gas Flow Range0.2–4 L/min (O₂)
VaporizerOriginal 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%)
CO₂ Absorbent Canister Capacity≥900 mL
Pressure Gauge Range0–60 cm H₂O
Circuit TypeDual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure)
ConstructionAnodized matte-finish aluminum chassis
ComplianceFDA-recognized materials (NASA-derived loop board), USP <1210> compatible design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSutter
OriginUSA
ModelP-97
TypeHorizontal Programmable Micropipette Puller
Heating MechanismDual-Independent Filament (Tungsten/Platinum)
Control ArchitectureMicroprocessor-Based with Ramp Detection Algorithm
Program Storage100 User-Defined Protocols with Write-Protection and Timestamping
Electrode SymmetryDual-Output Symmetric Pulling
Tip Diameter ReproducibilitySub-100 nm (verified by SEM)
Integrated Gas SystemRegulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization
DisplayVacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring
ComplianceDesigned for GLP/GMP-aligned electrophysiology workflows
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model454
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelC76688
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelTC-3000
Input ChannelsSingle or Triple Thermocouple
Temperature Range (Single-Channel)25.0–45.0 °C (0.1 °C resolution, Celsius only)
Temperature Range (Triple-Channel)−10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution
Sampling Rate3 Hz per channel
Power Supply4 × C-cell batteries (included)
OutputAnalog voltage output (0–5 V DC, proportional to temperature)
DisplayFront-panel LCD with manual channel selection
ComplianceCE-marked, RoHS-compliant, designed for laboratory use under GLP conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBLS
ModelFBL/Basic-B&N-01
Power SupplyDual-mode (battery or AC/DC adapter)
Excitation Wavelength Range470–660 nm
Emission Detection Range500–650 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelLE8815 / LE8816
External Dimensions450 × 450 × 200 mm or 220 × 220 × 200 mm
Infrared Frame Options450 × 450 mm (32 sensors, 25 mm spacing) or 250 × 250 mm (32 sensors, 13 mm spacing)
IR Wavelength950 nm
Sampling Frequency40 Hz
SoftwareActi-Track v5.x
Max Concurrent Channels32
Configurable ZonesSingle-animal or dual-animal (split-zone) mode
Behavioral MetricsDistance traveled, velocity profiles (max/min/mean), time-in-zone, zone entries, rearing count & duration, rotation counts, trajectory-based path analysis, nose-poke detection (threshold-defined), ambulation classification (fast/slow/immobility)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelGemini X2
WaveformsSquare Wave & Exponential Decay Wave
Voltage Range (LV)5–500 V (1 V step), 505–3000 V (5 V step)
Voltage Range (HV)505–3000 V (5 V step)
Pulse Duration (Square, LV)10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms)
Pulse Duration (Square, HV)10 µs–600 µs (1 µs)
Pulse Duration (Exponential, LV)1 ms–5.158 s
Pulse Duration (Exponential, HV)0.5 ms–133.875 ms
Pulse Count (Square)1–10 (LV), 1–3 (HV)
Pulse Count (Exponential)1–12 (R < 100 Ω), 1–24 (R > 100 Ω)
Inter-Pulse Interval0.1–10 s (Square), 5–30 s (Exponential)
Capacitance (LV)3775 µF
Capacitance (HV)85 µF
Capacitance (Exponential, LV)25–3275 µF (25 µF step)
Capacitance (Exponential, HV)10, 25, 35, 50, 60, 75, 85 µF
Resistance Measurement Range25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV)
Electrode CompatibilityBTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch
Software ControlUSB and Ethernet interface for protocol download, storage, and remote execution
Safety FeaturesArc suppression, short-circuit protection, real-time impedance monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelPP35-2P
TypeAdherent-cell-specific electroporation electrode
CompatibilityStandard 35 mm Petri dishes with 2 mm gap electrodes
ApplicationIn situ transfection of monolayer-cultured mammalian cells
ConfigurationDual parallel plate electrode assembly
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0