Empowering Scientific Discovery

Youcheng Biotechnology Co., Ltd. (Hong Kong)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBLS
OriginHungary
ModelCF-150C
Pulse Voltage Range (Square Wave)12–185 V
Pulse Duration10–200 µs
Inter-Pulse Interval200 µs
Pulse Count1–10
HF Oscillator Frequency1 MHz ±100 Hz
HF Amplitude (Coarse)0–30 V<sub>eff</sub>
HF Amplitude (Fine)0–3 V<sub>eff</sub>
Operating MediumElectrolytic or Non-electrolytic Solutions
Dimensions200 × 130 × 45 mm
Weight380 g
Power Consumption15 VA
Protection ClassClass I (Earthed)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBTX
OriginUSA
ModelBTX Model 524
Electrode TypeReusable tweezer-style in vivo electroporation electrode
Electrode Disk Diameter Options7 mm (Model 520) or 10 mm (Model 523)
Adjustable Inter-Electrode Gap<1 mm to >20 mm
Compatible Pulse GeneratorsBTX ECM 830, ECM 630, ECM T820, ECM 2001
Electrode MaterialStainless steel
Sterilization MethodEthanol or ethylene oxide
ConnectionBTX Model 524 Cable
ComplianceDesigned for GLP-compliant preclinical research workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBLS
OriginEU-manufactured
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginEuropean Union
ModelCF150B
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelGemini SC2
WaveformsSquare Wave & Exponential Decay Wave
Voltage Range (LV)5–500 V (1 V step), 505–3000 V (5 V step)
Voltage Range (HV)10–500 V (5 V step), 510–3000 V (10 V step)
Pulse Duration (Square, LV)10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms)
Pulse Duration (Square, HV)10 µs–600 µs (1 µs)
Pulse Duration (Exponential, LV)1.25 ms–3.275 s (1.25 ms)
Pulse Duration (Exponential, HV)0.5 ms–50 ms (0.5 ms)
Pulse Number (Square)1–10 (LV), 1–3 (HV)
Pulse Number (Exponential)1–12 (R < 100 Ω), 1–24 (R > 100 Ω)
Pulse Interval0.1–10 s (Square), 5–30 s (Exponential)
Capacitance (LV)3775 µF (fixed)
Capacitance (HV)85 µF (fixed)
Capacitance (Exponential, LV)25–3275 µF (25 µF step)
Capacitance (Exponential, HV)10, 25, 50 µF (selectable)
Resistance Measurement Range25–1575 Ω (25 Ω step, LV)
DisplayTouchscreen Interface
Preloaded ProtocolsYes
Arc SuppressionActive
Short-Circuit ProtectionIntegrated
ComplianceCE, RoHS, FDA-listed device (Class II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSutter
OriginUSA
ModelP-97
TypeHorizontal Programmable Micropipette Puller
Heating MechanismDual-Independent Filament (Tungsten/Platinum)
Control ArchitectureMicroprocessor-Based with Ramp Detection Algorithm
Program Storage100 User-Defined Protocols with Write-Protection and Timestamping
Electrode SymmetryDual-Output Symmetric Pulling
Tip Diameter ReproducibilitySub-100 nm (verified by SEM)
Integrated Gas SystemRegulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization
DisplayVacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring
ComplianceDesigned for GLP/GMP-aligned electrophysiology workflows
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model454
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBLS
ModelFBL/Basic-B&N-01
Power SupplyDual-mode (battery or AC/DC adapter)
Excitation Wavelength Range470–660 nm
Emission Detection Range500–650 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelGemini X2
WaveformsSquare Wave & Exponential Decay Wave
Voltage Range (LV)5–500 V (1 V step), 505–3000 V (5 V step)
Voltage Range (HV)505–3000 V (5 V step)
Pulse Duration (Square, LV)10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms)
Pulse Duration (Square, HV)10 µs–600 µs (1 µs)
Pulse Duration (Exponential, LV)1 ms–5.158 s
Pulse Duration (Exponential, HV)0.5 ms–133.875 ms
Pulse Count (Square)1–10 (LV), 1–3 (HV)
Pulse Count (Exponential)1–12 (R < 100 Ω), 1–24 (R > 100 Ω)
Inter-Pulse Interval0.1–10 s (Square), 5–30 s (Exponential)
Capacitance (LV)3775 µF
Capacitance (HV)85 µF
Capacitance (Exponential, LV)25–3275 µF (25 µF step)
Capacitance (Exponential, HV)10, 25, 35, 50, 60, 75, 85 µF
Resistance Measurement Range25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV)
Electrode CompatibilityBTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch
Software ControlUSB and Ethernet interface for protocol download, storage, and remote execution
Safety FeaturesArc suppression, short-circuit protection, real-time impedance monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHarvard Apparatus
OriginUSA
ModelPP35-2P
TypeAdherent-cell-specific electroporation electrode
CompatibilityStandard 35 mm Petri dishes with 2 mm gap electrodes
ApplicationIn situ transfection of monolayer-cultured mammalian cells
ConfigurationDual parallel plate electrode assembly
Show next