- All
- Favorite
- Popular
- Most rated
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 62 Max+ |
| Price | Available Upon Request |
| Temperature Range | -20 °C to 320 °C (-4 °F to 608 °F) |
| Accuracy | ±1.5 °C or ±1.5% of reading (whichever is greater), typical at 23 °C ±5 °C ambient |
| Resolution | 0.01 °C / 0.01 °F |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 increments) |
| Distance-to-Spot Ratio | 12:1 |
| Spectral Response | 8–14 µm |
| Response Time | <500 ms |
| Operating Environment | 0 °C to 50 °C, <95% RH non-condensing |
| Dimensions | 170 × 44 × 40 mm |
| Weight | 175 g |
| Display | Backlit LCD with dual-unit capability (°C/°F) |
| Laser Targeting | Single-point Class II laser (650 nm, <1 mW) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Not Specified |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Model | Homeothermic Blanket System |
| Origin | USA |
| Control Range | 35–40 °C (95–104 °F) |
| Preset Temperature | 37 °C |
| Probe Types | Flexible (2 mm Ø, 100 mm length) & Rigid Stainless Steel (1.6 mm Ø) |
| Blanket Sizes | Small (15 × 20 cm), Medium (45 × 70 cm), Large (60 × 90 cm) |
| Cable Length | 2 m (blanket & probe) |
| Power Delivery | Proportional DC control |
| Display | Front-panel LCD + LED power bar graph |
| Electrical Isolation | Floating design with optional grounding switch |
| Compliance | Designed for GLP-compliant in vivo physiological studies |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 601956 / 597569 |
| Pricing | Upon Request |
| Display | 3.5-digit, 12.7 mm (601956) / 18 mm (597569) high LED |
| Input Socket | Miniature T-type quick-disconnect (copper-constantan) |
| Power Supply | 4 × C-cell batteries (included) |
| Battery Life | 1200–2000 hours |
| Accuracy | ±0.1 °C ±1 digit |
| Resolution | 0.1 °C / 0.1 °F |
| Temp Range (601956) | 25–45 °C only |
| Temp Range (597569) | −10 to +60 °C (14–140 °F) |
| Output | Analog voltage output (connector not included) |
| Compliance | NIST-traceable calibration |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Handheld Digital Thermometer |
| Price | Upon Request |
| Temperature Range (°C) | −20 to +120 °C |
| Temperature Range (°F) | −58 to +302 °F |
| Accuracy (°C) | ±0.3 °C (−20 to +90 °C), ±0.5 °C (outside range) |
| Accuracy (°F) | ±0.5 °F (−4 to +194 °F), ±1.0 °F (outside range) |
| Response Time | ≤20 s |
| Power Supply | 1 × 1.4 V battery (3000-hour typical lifespan) |
| (Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 601961 |
| Pricing | Available Upon Request) |
| [Accuracy | ±0.5% of thermocouple range |
| Setpoint Accuracy | ±0.25% of full scale |
| Output Power | Continuously variable, up to 500 W (4.5 A @ 115 VAC) |
| Temperature Stability | –0.004 %/°C |
| Dimensions (W×H×D) | 17.2 cm × 13.3 cm × 5.7 cm |
| Weight | 1.02 kg |
| Input Voltage | 115 VAC, 60 Hz |
| Output Sockets | Two grounded 3-pin receptacles |
| Alarm Interface | AC-powered audible buzzer and visual lamp adapter] |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Heat Therapy Pump |
| Connector Type | Click-Tight or Colder |
| Flow Rate | 9–14 gal/hr |
| Operating Temperature Range | 85–107 °F |
| Hose Length | 10 ft (3 m) |
| Power Supply | 120 VAC, 60 Hz or 220 VAC, 50 Hz |
| Dimensions (W × D × H) | 8.5 × 5.6 × 6.25 in (20.6 × 14.3 × 16.2 cm) |
| Weight | 5.2 lb (2.6 kg) |
| Accuracy | ±2 °F |
| Mobility | Four swivel casters + integrated carrying basket |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TACT-2 |
| Price | Upon Request |
| Control Range | −100 to +400 °C |
| Accuracy | ±0.5 °C |
| Resolution | ±0.1 °C |
| AC Input | 110–230 V AC |
| Max AC Output (Resistive Load) | 700 W |
| DC Output | 12 V DC, 2 A max (TACT-2LV & TACT-2DF only) |
| Dual Setpoint Safety Limit | 40 °C (TACT-2LV & TACT-2DF only) |
| Dimensions (W × H × D) | 18.4 × 11.1 × 25.4 cm |
| Weight | <2.27 kg |
| Ground Leakage Current | <1 mA at 110 V AC |
Show next