Empowering Scientific Discovery

Leici DWG-8003 Fluoride Ion Online Monitor

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Leici
Origin Shanghai, China
Manufacturer Type Original Equipment Manufacturer (OEM)
Regional Classification Domestic (China)
Model DWG-8003
Price Range USD 7,000–14,000
Instrument Category Fluoride Ion Analyzer
Instrument Type Online Continuous Monitoring System
Measurement Range 0.05–1900 mg/L
Response Time (90%) ≤5 min
Resolution 0.01 mg/L
Accuracy ±10% of reading
Repeatability ≤3% RSD
Stability ±10% over 4 h
Power Supply AC 220 V ±10%, 50 Hz ±1%
Dimensions (W×D×H) 600 × 450 × 160 mm
Weight 50 kg
Output Isolated 4–20 mA DC (configurable span)
Temperature Control Integrated Peltier-based thermostatic module

Overview

The Leici DWG-8003 Fluoride Ion Online Monitor is an industrial-grade, continuous water quality analyzer engineered for reliable, long-term quantification of fluoride ion (F⁻) concentration in aqueous matrices. It operates on the potentiometric principle using a solid-state, lanthanum fluoride (LaF₃)-based ion-selective electrode (ISE), which delivers selective and stable electrochemical response to free fluoride ions in solution—free from interference by common anions such as chloride, nitrate, and sulfate under controlled pH and ionic strength conditions. Designed for unattended operation in demanding environmental and municipal infrastructure settings, the DWG-8003 integrates real-time measurement, automated calibration, temperature compensation, and self-cleaning functionality into a single rugged enclosure. Its architecture conforms to IEC 61000-6-2/6-4 electromagnetic compatibility standards and meets IP65 ingress protection requirements for installation in outdoor or semi-controlled environments.

Key Features

  • Potentiometric detection via high-stability LaF₃ membrane ISE with built-in reference electrode—optimized for low-drift performance in variable conductivity water streams
  • Integrated thermoelectric (Peltier) temperature control system maintaining sample cell at 25.0 ± 0.3 °C, eliminating thermal drift-induced measurement error
  • 7-inch capacitive touchscreen HMI with intuitive English-language UI; supports multi-level user access (operator, technician, administrator)
  • Automated calibration protocol with up to three-point standardization (e.g., 0.1, 1.0, 10.0 mg/L F⁻); calibration frequency programmable from 1 hour to 7 days
  • Programmable automatic electrode cleaning cycle using pressurized air or deionized water flush—reduces biofouling and extends sensor service life
  • Non-volatile internal storage (≥12 months of 1-min interval data at default logging rate); supports timestamped event logging for calibrations, alarms, and maintenance actions
  • Dual-output configuration: isolated 4–20 mA analog output (span and zero fully configurable) + selectable RS-232 or RS-485 serial interface (Modbus RTU protocol compliant)
  • Robust mechanical design: powder-coated steel chassis, corrosion-resistant fluidic path (PVDF and EPDM wetted materials), and redundant power supervision with battery-backed RAM for brownout resilience

Sample Compatibility & Compliance

The DWG-8003 is validated for direct analysis of raw and treated surface water, groundwater, drinking water, wastewater effluent, and industrial discharge streams—with minimal pretreatment required. Sample pH must be maintained between 5.0 and 8.0 (via optional inline pH adjustment module) to ensure optimal ISE selectivity and avoid hydroxide interference. Total dissolved solids (TDS) up to 5,000 mg/L are supported without signal suppression. The system complies with ISO 10523 (water quality — determination of pH), ASTM D3868 (standard test method for fluoride in water by ion-selective electrode), and supports audit-ready data integrity per GLP and GMP principles—including electronic signature capability, operator login tracking, and immutable calibration history logs. All firmware and configuration changes are time-stamped and attributable.

Software & Data Management

The embedded firmware supports local data visualization (trend charts, histograms, alarm logs) and exports CSV-formatted datasets via USB flash drive or serial export. Optional Leici DataBridge™ PC software enables remote configuration, historical data synchronization, and integration with SCADA or LIMS platforms via OPC UA or Modbus TCP gateways. All measurement records include metadata: sample ID, temperature, electrode potential (mV), slope (%), offset (mV), and calibration status flags. Audit trail functionality satisfies FDA 21 CFR Part 11 requirements when deployed with network authentication and role-based access controls.

Applications

  • Real-time fluoride monitoring at drinking water treatment plants to ensure compliance with WHO (1.5 mg/L) and EPA MCL (4.0 mg/L) regulatory thresholds
  • Effluent compliance verification for aluminum smelters, phosphate fertilizer facilities, and semiconductor wafer rinsing operations
  • Long-term trend analysis in watershed management programs assessing natural fluoride leaching from granitic bedrock
  • Process control feedback loop for fluoride dosing systems in municipal fluoridation stations
  • Early-warning detection of fluoride contamination events in reservoir intakes or distribution networks

FAQ

What sample preparation is required prior to analysis?
No filtration or chemical reagents are needed for typical surface or drinking water samples. For high-turbidity or high-organic-content wastewater, optional inline 5-µm cartridge filtration is recommended.
Can the DWG-8003 measure other halides?
No—it is specifically optimized for fluoride ion selectivity. Cross-sensitivity to chloride is <0.1% at 1000 mg/L Cl⁻; no factory calibration supports bromide or iodide quantification.
Is the system compatible with third-party SCADA systems?
Yes—via RS-485 Modbus RTU (default) or optional Ethernet-to-Modbus TCP converter; register mapping documentation is provided upon request.
How often does the fluoride ISE require replacement?
Under continuous operation in clean water, typical electrode service life exceeds 18 months; replacement intervals extend further with scheduled cleaning and proper storage in KF buffer.
Does the instrument support remote diagnostics?
Yes—through integrated Modbus registers reporting diagnostic codes (e.g., electrode slope degradation, temperature sensor fault, flow interruption), accessible via host system polling.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0