Empowering Scientific Discovery

Pickering Laboratories PINNACLE PCX DELTA Post-Column Derivatization System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Pickering Laboratories
Origin USA
Model PINNACLE PCX DELTA
Temperature Range Ambient to 150 °C (programmable, ±1 °C stability)
Derivatization Reagent Flow Rate 0.01–2.0 mL/min (precision ±0.5% RSD)
Reaction Coil Options PEEK, FEP, or stainless steel (0.25–1.0 mm ID, 1–30 m length)
Power Supply 100–240 V AC, 50/60 Hz

Overview

The Pickering Laboratories PINNACLE PCX DELTA is a purpose-built, high-precision post-column derivatization (PCD) system engineered for integration with high-performance liquid chromatography (HPLC) and ultra-high-performance liquid chromatography (UHPLC) platforms. It operates on the principle of controlled, time-resolved chemical reaction between eluting analytes and derivatizing reagents downstream of the analytical column—enabling sensitive, selective, and reproducible detection of compounds that lack native chromophores or fluorophores. Unlike generic auxiliary pumps or heated reactors, the PCX DELTA integrates thermally stabilized reaction zones, pulseless reagent delivery, and chemically inert fluidic pathways into a single architecture optimized specifically for post-column chemistry. Its design adheres to fundamental requirements of quantitative trace analysis in regulated environments—including precise temperature control, low dead-volume flow paths, and programmable reagent timing synchronization with gradient elution profiles.

Key Features

  • Pulseless Electronic Syringe Pump: Dual independent syringe drives deliver derivatization reagents at flow rates from 0.01 to 2.0 mL/min with ≤0.5% RSD, eliminating pulsation-induced baseline noise and improving peak shape fidelity.
  • Ceramic Monoblock Pump Head: Constructed from a single piece of chemically inert alumina ceramic, ensuring long-term compatibility with aggressive reagents (e.g., o-phthalaldehyde, ninhydrin, ortho-phthalaldehyde, FMOC-Cl) and resistance to corrosion or leaching.
  • Intelligent Solenoid Valve Architecture: Replaces mechanical check valves with electronically actuated, low-dead-volume solenoid valves—enabling automated prime-and-purge cycles, solvent flushing between runs, and zero manual maintenance.
  • Modular Reaction Coil Cartridge System: Interchangeable reaction coils (PEEK, FEP, or SS) allow rapid method switching without tubing cutting or ferrule replacement; coil dimensions are pre-characterized for kinetic optimization per application (e.g., amino acid vs. mycotoxin derivatization).
  • Forced-Air Column Oven with Gradient Capability: Maintains reaction zone temperature from ambient to 150 °C with ±1 °C stability; supports linear or stepwise temperature gradients synchronized with HPLC method files to enhance resolution of co-eluting derivatives.
  • Fully Inert Fluidic Pathway: All wetted surfaces—from pump seals to detector interface—are fabricated from PEEK, FEP, or passivated stainless steel, minimizing adsorption, carryover, and metal-catalyzed degradation of labile derivatives.

Sample Compatibility & Compliance

The PINNACLE PCX DELTA supports validated methods for over 50 compound classes across food safety, clinical diagnostics, environmental monitoring, and pharmaceutical QC. These include but are not limited to: amino acids (per AOAC 999.13, USP <621>), glyphosate and AMPA (EPA Method 547.1), carbamate pesticides (AOAC 2007.01), aflatoxins and ochratoxin A (EU Regulation 401/2006), aminoglycosides (USP <2021>), biogenic amines (ISO 1388-3), and paralytic shellfish toxins (AOAC 2005.06). The system’s hardware and firmware architecture comply with GLP/GMP data integrity expectations: audit-trail-enabled software logs all parameter changes, method executions, and calibration events. When operated with compliant LIMS or CDS platforms, it meets FDA 21 CFR Part 11 requirements for electronic records and signatures.

Software & Data Management

PCX Control Software v4.x provides instrument-level control via USB or Ethernet, enabling full remote configuration of pump flow rates, oven temperature profiles, valve sequencing, and real-time status monitoring. It supports method export/import in XML format and integrates seamlessly with major third-party chromatography data systems (CDS) including Thermo Chromeleon, Waters Empower, Agilent OpenLab, and Shimadzu LabSolutions through standardized API protocols. All derivatization parameters—including reagent start delay, reaction time window, and thermal ramp rate—are stored within the method file and automatically loaded during sequence execution. Raw instrument logs (including pressure traces, temperature deviations, and valve actuation timestamps) are archived in timestamped .csv format for retrospective review during method validation or regulatory audits.

Applications

The PINNACLE PCX DELTA serves as a core component in laboratories performing regulated analyses where derivatization is essential for detection sensitivity and selectivity. Typical use cases include: quantification of free and total amino acids in infant formula (per ISO 13903); determination of glyphosate residues in cereals and legumes (per EU SANTE/11312/2021); screening of fumonisins in maize using HPLC-FLD after o-phthalaldehyde derivatization; release testing of gentamicin sulfate in injectables (USP <2021>); and multi-analyte profiling of biogenic amines in fermented foods (ISO 20079). Its modularity also supports custom derivatization chemistries—such as hydrazide-based labeling for aldehydes/ketones or dansyl chloride tagging for primary amines—making it suitable for method development labs requiring flexibility without compromising robustness.

FAQ

Can the PINNACLE PCX DELTA be used with UHPLC systems operating at 1000 bar?
Yes—the system’s low-dispersion reaction coils and sub-10 µL total internal volume ensure compatibility with UHPLC flow rates (0.1–1.0 mL/min) and dwell-time-sensitive gradient methods.
Does the system support dual-reagent derivatization (e.g., two-step reactions)?
Yes—via optional dual-pump configuration and programmable valve sequencing, enabling precise timing of reagent addition, mixing, and heating steps.
Is calibration required before each run?
No—flow accuracy is factory-calibrated and maintained via syringe position feedback; however, periodic verification using gravimetric flow checks is recommended per ISO/IEC 17025.
What reagent compatibility documentation is available?
Pickering provides a comprehensive Chemical Compatibility Matrix covering >120 reagents—including strong acids, oxidizers, and organic solvents—validated against all wetted materials.
Can the PCX DELTA be integrated into automated sample-to-report workflows?
Yes—it supports standard communication protocols (RS-232, Ethernet TCP/IP) and exposes command-line interfaces for integration with robotic autosamplers and ELN/LIMS platforms.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0