Brand SOCOREX
Origin Switzerland
Model Digital 530
Type Manual Bottle Top Dispenser
Volume Range 0.1–100 mL
Minimum Increment 0.02 mL
Accuracy ±3.0% (per EN ISO 8655)
Precision (CV) ≤0.17% at max volume
Sterilization Fully autoclavable at 121°C / 250°F
Chemical Resistance PFA-coated piston, FEP/PCTFE/ETFE/PTFE/Borosilicate glass wetted parts

Overview

The SOCOREX Calibrex™ Digital 530 Inorganic Bottle Top Dispenser is an engineered precision liquid handling instrument designed for reproducible, contamination-controlled dispensing of aggressive inorganic solutions—including strong acids (e.g., HCl, HNO₃, H₂SO₄), strong bases (e.g., NaOH, KOH), saline buffers, and oxidizing reagents. Unlike conventional dispensers with glass or stainless-steel pistons vulnerable to corrosion or adsorption, the Digital 530 features a borosilicate glass piston coated with perfluoroalkoxy alkane (PFA), ensuring inert surface contact, minimal carryover, and long-term dimensional stability under repeated chemical exposure. Its mechanical architecture follows the positive-displacement principle: a calibrated piston moves within a sealed cylinder to displace an exact volume of liquid per stroke—eliminating reliance on air displacement and associated humidity/temperature sensitivity. The device complies fully with EN ISO 8655-3 (2022) for manual piston-operated dispensers, supporting traceable volumetric performance in GLP, GMP, and ISO/IEC 17025 environments.

Key Features

  • PFA-Coated Glass Piston: Chemically inert coating prevents adhesion, leaching, or degradation when handling concentrated mineral acids, caustics, and high-ionic-strength solutions—enabling consistent delivery across >10,000 cycles without recalibration.
  • Dual Volume Adjustment System: Equipped with both a sliding vernier cursor (lock-and-slide mechanism) and a rotary volume knob—users select based on ergonomic preference or lab SOP requirements; both offer tactile feedback and sub-milliliter resolution down to 0.02 mL.
  • Full Visual Flow Path: Transparent ETFE body and integrated viewing window allow real-time observation of piston travel, meniscus position, and fluid continuity—critical for verifying priming, detecting bubbles, or confirming complete aspiration/dispense.
  • 360° Rotatable Dispensing Tip: The 120 mm standard dispensing tube rotates freely around its axis, enabling optimal positioning over narrow-necked flasks, centrifuge tubes, or multi-well plates without repositioning the entire bottle assembly.
  • Three-Position Flow Control Valve: “A” = internal recirculation (for priming or rinsing without waste), “B” = dispensing mode, “C” = lock (prevents accidental actuation during transport or storage); valve components are fully autoclavable and tool-free to disassemble.
  • Integrated Calibration Access: A recessed, tamper-resistant calibration button—protected by a removable cap—is accessible without disassembly, permitting rapid field adjustment per ISO 8655 verification protocols.

Sample Compatibility & Compliance

The Digital 530 is validated for use with aqueous, acidic, alkaline, and saline media where compatibility with fluoropolymer and borosilicate surfaces is required. Wetted materials include FEP inlet tubing, PFA-coated glass piston, PTFE valve seats, ceramic ball valves, ETFE housing, and FEP/PCTFE dispensing nozzles—all certified to USP Class VI and EU Pharmacopoeia 3.1.1 standards. It meets EN ISO 8655-3:2022 accuracy and repeatability specifications across its full 0.1–100 mL range, with CV ≤0.17% at maximum volume and accuracy within ±0.6% at mid- to high-range settings. Each unit ships with a factory-issued calibration certificate bearing a unique serial number and traceability to national metrology institutes (e.g., METAS, NIST). The device supports audit-ready documentation for FDA 21 CFR Part 11 compliance when paired with SOCOREX’s optional digital logbook software.

Software & Data Management

While the Digital 530 operates manually, it integrates seamlessly into digitally governed workflows via SOCOREX’s optional CaliLog™ Desktop Software (sold separately). This Windows-based application enables electronic recording of calibration events, user-defined dispensing protocols, version-controlled SOP attachments, and export of PDF/CSV audit trails compliant with ALCOA+ principles. All calibration adjustments performed using the built-in button are timestamped and logged locally on the device’s non-volatile memory—retaining up to 500 entries with operator ID, date/time, pre- and post-adjustment values, and deviation metrics. No firmware updates or cloud connectivity are required for basic operation, ensuring data sovereignty and network isolation in secure laboratory environments.

Applications

  • Preparation of standardized acid/base titrants in analytical chemistry labs
  • Accurate dispensing of buffer solutions (e.g., PBS, Tris-HCl) in molecular biology workflows
  • Reagent distribution for ICP-MS, AAS, and ion chromatography sample introduction systems
  • Quality control testing of pharmaceutical excipients requiring strict pH and ionic strength control
  • Environmental testing labs handling EPA Method 300.0–300.1 compliant dilutions of wastewater extracts
  • Academic research involving corrosive catalysts (e.g., AlCl₃ in chlorinated solvents) where metal-free contact is mandatory

FAQ

Is the Digital 530 compatible with hydrofluoric acid (HF)?
No. While PFA exhibits excellent resistance to most mineral acids, HF attacks silica-based substrates—including borosilicate glass—even through fluoropolymer coatings. For HF applications, consult SOCOREX’s specialized HF-rated dispensers with sapphire pistons.
Can the dispenser be sterilized in a steam autoclave without disassembly?
Yes. The entire unit—including piston, valve block, and housing—is rated for full-cycle autoclaving at 121°C / 250°F for 20 minutes, per ISO 17665-1. All seals and springs retain integrity after ≥50 cycles.
What bottle neck sizes does the standard adapter support?
The included 45 mm universal bottle adapter accepts bottles with 32 mm, 38 mm, and 40 mm thread diameters via three interchangeable inserts supplied with the unit.
How often should calibration be verified?
Per ISO/IEC 17025:2017 Clause 7.7, calibration verification is recommended before each critical batch, after maintenance, or at least daily in high-throughput QC labs. Routine checks using gravimetric methods per EN ISO 8655-6 are advised.
Does the red color coding indicate regulatory certification?
No. The red identification ring is a visual cue for inorganic compatibility only—not a regulatory mark. Certification status is documented in the included Certificate of Conformance and calibration report.