Thermo Fisher K114 Box-Type Muffle Furnace

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Thermo Fisher
Origin USA
Manufacturer Thermo Fisher Scientific
Type Box-Type Muffle Furnace
Model K114
Maximum Temperature 1100 °C
Temperature Uniformity ±6 °C
Control Accuracy ±2–4 °C
Heating Method Resistance Wire Heating
Internal Dimensions 170 × 130 × 160 mm
Chamber Volume 3.5 L
Max Power 690 W
Ramp Rate to Max Temp 6–12 °C/min
External Dimensions 456 × 646 × 570 mm
Net Weight 36 kg
Power Supply 230 V, 50/60 Hz
Insulation Asbestos-Free Refractory Material

Overview

The Thermo Fisher K114 Box-Type Muffle Furnace is a compact, CE-marked laboratory furnace engineered for precise thermal processing in research, quality control, and routine analytical workflows. Designed around a robust resistance wire heating system embedded in high-density, asbestos-free refractory insulation, the K114 delivers stable, repeatable temperature profiles up to 1100 °C. Its muffle architecture isolates the sample chamber from combustion byproducts and heating elements—ensuring contaminant-free thermal treatment essential for ashing, calcination, heat treatment of ceramics, and gravimetric analysis per ASTM E1867 and ISO 5660-1. With a 3.5 L working volume and optimized thermal mass distribution, the furnace achieves typical ramp rates of 6–12 °C/min to maximum temperature (reaching 1100 °C in approximately 100 minutes under no-load conditions), while maintaining ±6 °C temperature uniformity across the chamber—a critical parameter for method reproducibility in GLP-compliant laboratories.

Key Features

  • Asbestos-free ceramic fiber insulation minimizes external surface temperature rise and reduces standby energy consumption by up to 25% compared to traditional insulating bricks.
  • Downward-opening door design improves operator ergonomics and enhances safety by limiting radiant exposure during sample loading/unloading—particularly advantageous under fume hood constraints.
  • Digital PID temperature controller with dual-sensor input enables real-time deviation monitoring and auto-compensation for ambient drift; control accuracy is maintained at ±2–4 °C across the full operating range.
  • Compact external footprint (456 × 646 × 570 mm) allows integration into space-limited lab environments—including placement directly beneath standard laboratory fume hoods (minimum clearance: 600 mm).
  • Refractory chamber liner rated for continuous operation at 1100 °C; all internal surfaces are resistant to oxidation and thermal shock, supporting long-term stability in repeated thermal cycling applications.
  • Integrated over-temperature protection with independent mechanical cut-off (bimetallic switch) ensures fail-safe shutdown if primary control fails—meeting IEC 61000-6-2 EMC and IEC 61010-1 safety requirements.

Sample Compatibility & Compliance

The K114 accommodates standard crucibles (up to 100 mL porcelain or alumina), watch glasses, and small metal specimens within its 170 × 130 × 160 mm chamber. It supports standardized procedures including USP <231> heavy metals testing, AOAC 942.05 ash content determination, and ASTM D3174 coal ash analysis. The furnace complies with CE marking directives (2014/30/EU EMC, 2014/35/EU LVD), carries full conformity documentation for FDA-regulated environments, and meets the electrical safety and thermal emission criteria required for inclusion in ISO/IEC 17025-accredited testing laboratories. Its asbestos-free construction aligns with EU Directive 2003/18/EC and OSHA 29 CFR 1910.1001 standards.

Software & Data Management

While the K114 operates via a front-panel digital controller without built-in data logging, it features an RS-232 serial interface compatible with Thermo Fisher’s optional LabManager™ PC software (v4.2+). This enables remote setpoint programming, real-time temperature graphing, event-triggered data capture (e.g., dwell start/end), and export of time-stamped CSV files compliant with 21 CFR Part 11 audit trail requirements when paired with validated user access controls and electronic signature modules. All temperature profiles can be saved as reusable methods, facilitating SOP-driven operation in GMP manufacturing QC labs.

Applications

  • Quantitative ash residue analysis in food, pharmaceutical, and environmental samples (e.g., EPA Method 2540E).
  • Pre-treatment of catalyst supports and battery electrode materials prior to BET surface area measurement.
  • Heat treatment of metallurgical specimens for microstructural stabilization before metallographic examination.
  • Calcination of precipitated oxides (e.g., ZnO, TiO₂) in nanomaterial synthesis protocols.
  • Residue-on-ignition (ROI) testing in water and wastewater sludge characterization per Standard Methods 2540F.
  • Thermal validation of sterilization packaging components under controlled dry-heat cycles.

FAQ

Does the K114 support programmable multi-step temperature ramps?
Yes—when connected to LabManager™ software, users can define up to 16 segments per profile, including ramp rates, dwell times, and cooling steps.
Is calibration certificate included with shipment?
A factory-issued NIST-traceable calibration report (covering 200 °C, 600 °C, and 1000 °C points) is provided; on-site IQ/OQ documentation packages are available upon request.
Can the furnace be used continuously at 1100 °C?
Rated for continuous operation at 1100 °C, though recommended duty cycle is ≤8 hours/day to maximize heating element service life.
What maintenance is required for long-term reliability?
Annual inspection of door gasket integrity, thermocouple calibration verification, and visual check of heating coil continuity using a multimeter are advised.
Is the K114 suitable for inert-atmosphere applications?
No—it lacks gas inlet/outlet ports or pressure-rated seals; for controlled atmospheres, consider the Thermo Fisher Lindberg/Blue M VHT series with purge capability.